background image

 

 

 

 

 

 

 

TP/TH/TG

 series 

HMI

 

manual

Hardware

 

 

 

 

 

 

 

 

 

 

 

WUXI XINJE ELECTRIC CO., LTD. 

Data No. : HC 01 20120105 2C

Summary of Contents for TP Series

Page 1: ...TP TH TG series HMI manual Hardware WUXI XINJE ELECTRIC CO LTD Data No HC 01 20120105 2C6...

Page 2: ......

Page 3: ...2 1 2 Model naming rule 11 2 1 3 Model form 11 2 2 General specifications 12 2 3 Hardware 14 2 3 1 Hardware structure 14 2 3 2 Port introduction 14 2 4 Dimensions and installation 20 2 4 1 Product di...

Page 4: ......

Page 5: ...erman French Arabic etc The fonts support any size artistic effect bold italic etc Large program capacity support more program screens and data Control Dynamic data displaying and monitoring bar map r...

Page 6: ...mperature 25 running for 24 hours Language Chinese English Japanese Korean German French Arabic Character Any font and size Memory Capacity 2MB 4MB Electric specifications Item TP460 L TP760 T Electri...

Page 7: ...n mm 165 2 113 4 182 4 134 4 Ports PLC port Support RS232 RS485 RS422 Download port Support RS232 RS485 1 3 Hardware 1 3 1 Hardware structure The hardware structure of TP series touch screen includes...

Page 8: ...sed terminal 1 Download function When you use download function of TP series please use Xinje special download cable Before user download a program please make sure your PC has installed multiport ser...

Page 9: ...t of TP series not only has the download function but also has the powerful communication function When use the communication function of download port please shorted the pin 5 and pin 6 select the co...

Page 10: ...nication port Pin Definition Description 1 TD RS422 send 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 5 GND Signal ground 6 TD RS422 send 7 B RS485 8 RDD RS422 receive 9 RDD RS422 receive 1 Communic...

Page 11: ...tocol 3 Communicate with meters About the communication between TP and meters users can select user defined protocol or Modbus protocol 1 4 Dimension and installation 1 4 1 Product dimensions TP460 L...

Page 12: ...ght side of the TP when installing Install steps 1 Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet 2 Add airproof circles in the airproof slot whe...

Page 13: ...screen use DC 24V power supply only The permitted voltage range is 20V 26V The connection is as below 24V 0 V DC DC 0 V 24V Terminal type Pin type Besides if connect high voltage or AC power supply w...

Page 14: ...e Korean Define the font as you like support underline italic bold shadow and other art words Large picture library with preloading mode no delay for screen motion Control Switch control dynamic monit...

Page 15: ...Increase a com port RS232 base on the TH465 MT UT TH765 NT3 NU3 Increase a com port RS485 base on TH765 NT NU 2 1 3 Model form TH series include TH465 TH765 TH865 THA62 and THA65 1 About the hardware...

Page 16: ...800 480 128M B 232 485 232 485 42 2 THA62 UT 2 THA65 THA65 MT 10 4 800 600 128M B 232 485 232 485 42 2 THA65 UT 2 TH series add two kind of power off retentive registers PHW 520 thousand registers an...

Page 17: ...d voltage AC1000V 10mA less than 1 minute signal and ground Insulated impedance DC500V above 10M signal and ground Environment Operation temperature 0 50 Reserve temperature 20 60 Humidity 10 RH 90 RH...

Page 18: ...w is the back side of TH series HMI 2 3 2 Port introduction TH series HMI port Outline Name Function 1 2 3 4 1 2 3 4 DIP switch Force download touch area adjustment Download COM 1 RS232 RS485 communic...

Page 19: ...wnload to update the system Steps 1 Cut off the power of TH turn ON DIP switch 2 2 Power on TH connect the download cable to PC to download the program 3 Turn OFF DIP switch 2 after finishing the down...

Page 20: ...D RS422 receive The COM1 pins definition of TH765 NT3 NU3 series Pin Name Description 1 A RS485 signal 2 RXD RS232 receive 3 TXD RS232 send 4 A RS485 signal 5 GND Signal ground 6 B RS485 7 B RS485 8 N...

Page 21: ...port COM2 device and communication parameters COM2 device selection COM2 communication parameter setting Select the correct download port COM1 device and communication parameters COM1 device selectio...

Page 22: ...series USB A port has below functions accord with USB2 0 Backup management data export import the speed can up to 480 Mbps USB A port definition Connect to USB flash drive 4 USB B port TH has one USB...

Page 23: ...USB cables 2 Please install USB driver before using Download the driver from www xinje com 3 Connect TH with PC open Touchwin software click or to download the program Pin Name Description 1 5V 5V vol...

Page 24: ...mm 24V 0V FG 1 2 3 4 92 0 142 0 41 8 152 0 102 0 144 0 94 0 PLC 1 2 3 4 0 5 0 0 0 5 0 0 TH765 M TH765 N Unit mm 1 2 3 4 24V 0V FG 1 2 3 4 COM1 COM2 MODE TW760T S N N20081028028 THINGET Xinje Electron...

Page 25: ...nit mm 1 2 3 4 1 2 3 4 Download PLC 24V 0V FG 224 4 170 8 38 0 45 5 155 8 209 4 0 5 0 0 0 5 0 0 211 4 157 8 THA62 Unit mm Download PLC 24V 0V FG 1 2 3 4 272 2 191 7 51 2 258 2 177 7 260 2 179 7 1 0 0...

Page 26: ...the up down and 5cm on the left right side of the TH when installing Install steps 1 Refer to the dimension in the former chapter to open a rectangle mounting hole in the control cabinet 2 Add airproo...

Page 27: ...re inside TH Power supply requirements TH series touch screen use DC 24V power supply only The permitted voltage range is 20V 28V The connection is as below Besides if connect high voltage or AC power...

Page 28: ...substantially Support multi language Chinese English Japanese Korean German French Arabic etc The fonts support any size artistic effect bold italic etc Rich images of material screen operation Contro...

Page 29: ...act type of TG765 MT it has USB B port one RS232 port with clock 3 1 3 Product models Model LCD size Display Notes TG765 MT UT ET TG765 XT TG765 XT C 7 TFT LCD MT USB B download port UT USB B download...

Page 30: ...French Arabic Character Any font and size Memory Capacity 128MB Electric specifications Item TG765 TG865 TGA62 TGC65 Electric Input voltage DC24V Range DC22V DC26V Consumpt ion current 200mA 230mA 25...

Page 31: ...2 410 0 270 0 65 0 Mounting dimension mm 192 0 138 5 211 4 157 8 260 2 179 7 399 0 259 0 Interface PLC port RS232 RS485 RS422 TG765 XT TG765 XT C only support RS232 Download port RS232 RS485 TG765 XT...

Page 32: ...load touch area adjustment Download Download port RS232 RS485 PLC PLC port RS232 RS485 RS422 USB A Connect to USB flash drive USB B Connect USB cable to download upload program Ethernet port Support T...

Page 33: ...Cut off the power of TG turn ON DIP switch 2 2 Power on TG connect the download cable to PC to download the program 3 Turn OFF DIP switch 2 after finishing the download repower on the TG 1 2 3 4 ON OF...

Page 34: ...d with USB2 0 of TG series HMI has below function Backup management data export import the speed can up to 480 Mbps USB A port definition 4 USB B port TG has one USB B port accord with USB2 0 located...

Page 35: ...en Touchwin software click or to download the program 5 RJ45 port The pins definition of RJ45 port 1 8 Pin Color Name Explanation 1 Orange white TXD Send 2 Orange TXD Send 3 Green white RXD Receive 4...

Page 36: ...1028028 THINGET Xinje Electronic Co Ltd 43 4 6 6 200 4 146 9 136 5 190 0 138 5 192 0 PWR TG765 XT TG765 XT C Unit mm 1 2 3 4 24V 0V FG 1 2 3 4 MODE TG760T XT S N N20121028028 TouchWin Xinje Electric C...

Page 37: ...3 TG865 MT UT ET Unit mm 211 4 157 8 1 2 3 4 1 2 3 4 Download PLC 24V 0V FG 155 8 209 4 224 4 170 8 38 0 45 5 TGA62 MT ET Unit mm Download PLC 24V 0V FG 1 2 3 4 272 2 191 7 51 2 258 2 177 7 260 2 179...

Page 38: ...unting rack to fix the TG with control cabinet In order to avoid TG temperature too high after long time working please keep 10cm space on the up down and 5cm on the left right side of the TG when ins...

Page 39: ...uch screen indoor Do not use TG in below environment Inflammable gas steam dust fast vary temperature high humidity it may cause moisture inside TG Power supply requirements TG series touch screen use...

Page 40: ......

Page 41: ...WUXI XINJE ELECTRIC CO LTD 4th Floor Building 7th No 100 Dicui Rd Wuxi China Tel 86 0510 85134139 Fax 86 0510 85111290 www xinje com Email cheerfiona gmail com...

Reviews: