background image

 

- 1 - 

 

 

1

 

In general, safety guidelines .................................................................................................................... 2

 

2

 

Scope of delivery: .................................................................................................................................... 3

 

2.1

 

Legend Fig. 1a (handpiece): .............................................................................................................. 3

 

2.2

 

Legend Fig. 1b (table control unit): ................................................................................................... 3

 

3

 

Technical data: ........................................................................................................................................ 4

 

3.1

 

Handpiece:........................................................................................................................................ 4

 

3.2

 

Control unit:...................................................................................................................................... 4

 

4

 

Description of the device: ........................................................................................................................ 4

 

4.1

 

Handpiece ......................................................................................................................................... 4

 

4.2

 

Description of the table control unit................................................................................................... 5

 

5

 

Before commissioning: ............................................................................................................................ 5

 

5.1

 

Changing tools, clamping pins or bits and cutters .............................................................................. 6

 

6

 

Working with the Xenox Nail 35K:......................................................................................................... 6

 

6.1

 

Commissioning with manual rotational speed adjustment ................................................................... 6

 

6.2

 

Operation with rotational speed adjustment using the food pedal(accessory, not included in delivery) 7

 

7

 

Maintenance, cleaning and care.............................................................................................................. 8

 

7.1

 

Replacing the carbon brushes ............................................................................................................ 8

 

8

 

Disposal: .................................................................................................................................................. 9

 

9

 

Malfunctions............................................................................................................................................ 9

 

9.1

 

Replacing the safety fuse.................................................................................................................... 9

 

10

 

Checklist ............................................................................................................................................ 10

 

11

 

Accessories:........................................................................................................................................ 11

 

11.1

 

Foot pedal ....................................................................................................................................... 11

 

12

 

Service note: ...................................................................................................................................... 11

 

13

 

CE Declaration .................................................................................................................................. 12

 

 

Summary of Contents for Nail 35K

Page 1: ...ioning 5 5 1 Changing tools clamping pins or bits and cutters 6 6 Working with the Xenox Nail 35K 6 6 1 Commissioning with manual rotational speed adjustment 6 6 2 Operation with rotational speed adjustment using the food pedal accessory not included in delivery 7 7 Maintenance cleaning and care 8 7 1 Replacing the carbon brushes 8 8 Disposal 9 9 Malfunctions 9 9 1 Replacing the safety fuse 9 10 C...

Page 2: ...nical progress XENOX will not be liable for the safe function of the device for handling that does not comply with the usual intended use other application uses that are not stated in the instructions incorrectly executed repairs disregard of the safety regulations external effects for which the manufacturer is not responsible We grant a one year full warranty also to wearing parts For your safety...

Page 3: ...sing part clamping ring 4 Motor housing 5 Connecting cable with housing cap 6 Handpiece rest 2 2 Legend Fig 1b table control unit 1 Housing 2 On Off switch 3 Warning light 4 Switch for clockwise anticlockwise rotation 5 Rotational speed adjusting knob 6 Housing recess for tool holder 7 Connection socket for handpiece 8 Connection socket for foot pedal 9 Changeover switch for hand adjustment foot p...

Page 4: ...ption of the device 4 1 Handpiece The Xenox nail 35k handpiece is designed for use in the sector of foot care or pedicure but can also be used in many other related areas of course A maximum rotational speed of 35 000 min and a high torque offers the best requirements for effective work with large material removal and greatest precision The output shaft has an extremely accurate balance and is gui...

Page 5: ...the safe operation of the device The handpiece may not be operated without the supplied pin or matching bits and cutters If the collet is empty or in the open position the motor will not run and the warning LED on the control unit begins to glow The handpiece may only be operated with the supplied control unit You must comply with the rotational speed specifications of the bits and cutters manufac...

Page 6: ...s and cutters should be inserted as far as possible but at least 10 mm into the collet for secure clamping Short clamping increases the mechanical load while working with the device and prevents the secure seating of the tool Attention To change the tools the handpiece must be switched off and or it may not be connected to the control unit Twist the clamping ring 1 Fig 2 of the handpiece against t...

Page 7: ...e varied with the rotational speed adjusting knob during operation 6 2 Operation with rotational speed adjustment using the food pedal accessory not included in delivery The foot pedal enables convenient and fatigue proof work without having to set down the handpiece during work to adjust the rotational speed or without having to switch the handpiece on or off Switching the device on and preselect...

Page 8: ...The external surface of the handpiece can be cleaned using a soft possibly moist cloth Mild soap or other suitable cleanser e g isopropanol may also be used Do not use solvents as these could attack the plastic housing casings Make sure that no cleansers penetrate the interior of the handpiece Caution when using compressed air for cleaning The dirt or dust that penetrates could damage the handpiec...

Page 9: ...cipal disposal company or other appropriate municipal institutions 9 Malfunctions Please note that for safety reasons you must disconnect the mains plug before you replace the safety fuse 9 1 Replacing the safety fuse If the device fails the safety fuse installed in the device could be blown and must be replaced The fuse is located next to the socket for connecting the mains power input Simply twi...

Page 10: ...outlet conducting voltage When On Off switch is in On position the operating light lights up but the motor does not run LED next to the On Off switch is glowing Clamping system is open Clamping system is closed but no pin tool is inserted Close clamping system Insert tool Tool or pin is not held firmly enough in the collet Diameters of tool shaft collet do not match Collet is worn Collet has becom...

Page 11: ...rts on offering high quality at reasonable prices All devices that leave our company have received a final inspection and test so we grant a 1 year unlimited warranty as of purchase date for function and material in the form of free repair and free replacement of defective parts In case of warranty or a defect of if the device requires technical maintenance please contact our Central Service direc...

Page 12: ...ectives Low Voltage Directive 2006 95 EC EMC Directive 2004 108 EC The following standards and documents were used Safety requirements for electrical equipment for measurement control and laboratory use Part 1 General requirements EN 61010 1 2001 Electrical equipment for measurement control and laboratory use EMC requirements Part 1 General requirements EN 61326 1 2006 Jörg Wagner Development Cons...

Reviews:

Related manuals for Nail 35K