background image

 

 

 

 

 

 

 

EasIR

TM

-4 / EasIR

TM

-2/ EasIR

TM

-1  

Thermal Camera 

 

 

User Manual 

 

 

 

 

Wuhan Guide Infrared Co., Ltd.   
No. 26 Shucheng Rd, Hongshan District, Wuhan 430070 P. R. China 
Telephone: +86-27-8767 1991 
Facsimile: +86-27-8767 1927 
Email: [email protected] 
Internet: www.guide-infared.com 
©    Wuhan Guide Infrared Co., Ltd., 2009 
Version No: 2010-02-22 

 

 

Summary of Contents for EasIR-1

Page 1: ...uhan Guide Infrared Co Ltd No 26 Shucheng Rd Hongshan District Wuhan 430070 P R China Telephone 86 27 8767 1991 Facsimile 86 27 8767 1927 Email overseas guide infrared com Internet www guide infared c...

Page 2: ...relating to electromagnetic compatibility and safety EMC directive 89 336 EEC Low voltage directive 73 23 EEC Copyright Wuhan Guide Infrared Co Ltd 2009 All rights reserved worldwide No parts of the p...

Page 3: ...tions 1 Maintenance 2 Calibration and Repair Philosophy 2 Technical Support 3 Feedback to Us 3 System Overview 3 System Configuration 3 Technical Specification 4 System Features 6 Parts Described 8 Ch...

Page 4: ...ASIRTM 1 Thermal Camera at very high intensity radiation sources such as the sun carbon dioxide lasers or arc welders etc Do not expose the EASIRTM 4 EASIRTM 2 EASIRTM 1 Thermal Camera to dust and moi...

Page 5: ...h a soft cloth dampened with water and a mild detergent Optical surfaces The lens of an IR camera is very expensive Replacement or repair may be thousands of dollars The anti reflective coating on the...

Page 6: ...on the cover of this User Manual or by email to the following address overseas guide infrared com System Overview EASIRTM 4 EASIRTM 2 EASIRTM 1 is a new infrared camera of Guide infrared breaks the IR...

Page 7: ...0 pixels 25 m Spectral Range 8 14 m Thermal Sensitivity 100mk at 30 Field of View Focus 20 6 X 15 5 11mm Palette 8 6 4 Focus Automatic or motorized thermal visual Motorized thermal Motorized thermal V...

Page 8: ...ation Class 2 semiconductor laser N A Power System Battery Type AA rechargeable battery field replaceable AA Alkaline battery also usable Charging System In camera or in battery charger Battery Operat...

Page 9: ...owerful analysis software support image information read in powerful further analysis live trend analysis multipage generation by over 9 IR images real time video recording report generation analyzes...

Page 10: ...2 to protect optics 3 for outdoor inspections USB 2 0 Realtime image video data transfer to PC and real time control of the camera on PC realizes video transfer and operation control User can record o...

Page 11: ...User Manual Parts Described 1 LCD Display 2 Charging Indicator 3 Function Softkeys 4 Microphone 5 Battery Cover 6 Speaker 7 Visual Camera 8 Laser 9 IR Lens 8...

Page 12: ...indicator will be constant red for both powering on and off y Do not use the adapter when there are non rechargeable batteries in the battery compartment How to use the batteries y Insert the batterie...

Page 13: ...ies together to operate the camera y Do not mix batteries of different types together to operate the camera y AA Alkaline batteries are not chargeable y Please take out all the batteries when the came...

Page 14: ...nalysis mode Left Right Up Down Press button to switch between the X or Y coordinate of the spot Press button or button to adjust the value of X or Y s coordinate Press button T to exit the spot analy...

Page 15: ...s no menu on the screen press button T to freeze the image the following info will be displayed on the screen Save Voice Visual IR y Press button T again to exit frozen mode and return to the real tim...

Page 16: ...ode press button to enter sub menu parameter setting Emiss Tamb Distance Palette RelHum Laser OK y In the sub menu Parameter press button to confirm the highlighted option and enter the next sub menu...

Page 17: ...e To automatically focus y Aim the lens at the target y Press to activate the menu y Make sure the target is in the middle of the LCD and then press the softkey labeled Auto until the image on the LCD...

Page 18: ...anual mode and to adjust Tmin and Tmax manually Tmin Tmax y Press button to increase the Tmax value press button to decrease the value press button to switch between Tmin and Tmax adjustment mode y Pr...

Page 19: ...notation can only be added before saving an image When freeze an image the Image Capture menu appears To add a voice annotation to the image y Press the softkey labeled Voice y Press the softkey label...

Page 20: ...r setting then choose Tamb and select Set option to set the value manually by pressing button and button The new measurement will be based on the saved tamb value until re enter Tamb option and exit w...

Page 21: ...USB2 0 for further analysis by Guide IR software The Infrared video function is displayed in the computer and controlled by the Guide IR Analyser Before the communication please install the USB drive...

Page 22: ...ox as following Select and press ok to confirm the infrared video is open as following z Open Film Use this command to open the saved Video file in the directory path of PC The software will play this...

Page 23: ...ry when opening infrared video and perform the track circle Menu Bar Menu bar consists of seven sub menu options including File Video Measure Tools View Window and Help Keeping left button of the mous...

Page 24: ...ightness of each image file This command utilizes this mapping function to adjust brightness of the current opening image file Dialog box of Temp Range will appear after choosing this command Moving t...

Page 25: ...aying video Record command Use this command or press to record the video capture and save it in appointed directory The default saving directory is in the sub directory of capture under installation d...

Page 26: ...camera you have to install the camera USB Driver to PC and use the Guide IrAnalyser software to transfer images to PC Install USB driver to PC When there is no menu in the live thermal image properly...

Page 27: ...User Manual y Installation starts When getting to the step as shown below choose Continue anyway to proceed further y Installation continues and finishes quickly Click button Finish 24...

Page 28: ...Controller it indicates the driver has been properly installed and you can transfer data from the camera to PC now y The procedures to go to Device Manager is as follows Clicking My Computer Clicking...

Page 29: ...User Manual 26...

Reviews: