Summary of Contents for Rapport mini HD

Page 1: ...P N 388087345 PRINTED IN KOREA Rapport mini HD Multi Functional CCTV Tester FAR OPEN TELE OSD NEAR CLOSE WIDE COM V 300V 300V MAX V MODE SET ...

Page 2: ...er ON OFF Mode setup Video Tester Switch CVBS HD SDI and HD TVI Digital Multimeter Measuring AC DC Voltage Measuring Resistance Continuity Testing PTZ Controller SPD SPEED GPST GO TO PRESET SPST SET PRESET FUNC MENU 4 5 6 6 8 12 14 15 16 16 17 18 20 22 24 25 25 26 28 29 29 29 30 DATA SETUP USER NAME SLEEP TIME BEEP SYMBOLS 31 33 34 34 34 35 02 MULTI FUNCTIONAL CCTV TESTER 03 MULTI FUNCTIONAL CCTV ...

Page 3: ...dity 30 90 DC input voltage 12V 10 1A Rapport mini HD Safety Precautions Use only specified replacement fuses Do not use damaged test leads with the DMM When using the DMM function set the proper mode before connecting to the circuit under est When measuring resistance make certain that the circuit is de energized before connecting the test leads to the circuit Do not measure resistance on powered...

Page 4: ...attery Therefore when the Rapport mini HD is not being used for a period of time make sure the Main Switch is turned off PRODUCT INTRODUCTION PRODUCT INTRODUCTION Summary Standard Items Check the contents of your Rapport mini HD package against the standard checklist below Designed with portability and serious CCTV engineers in mind the Rapport mini HD is an advanced piece of video test equipment ...

Page 5: ...ration Mode Select Video MultiMeter PTZ Control Used to confirm selection in menu screens Press for 2 seconds to power on Adjusts PTZ Focus Far Operation IRIS OPEN Part Name Function Part Name Function PTZ mode PTZ mode PTZ mode PTZ mode Test Lead Connection Ports for Digital MultiMeter V COM Adjusts PTZ Focus Near Operation IRIS Close Adjusts PTZ Focus Zoom in Operation Clear OSD of PTZ mode Adju...

Page 6: ...ut of PTZ communications signals RS 422 RS485 Rx Rx Tx Tx PRODUCT INTRODUCTION PRODUCT INTRODUCTION Video IN Select function in video selection mode Video IN The input video signal of CVBS NTSC PAL HD SDI and HD TVI display to the LCD Press button for 3 sec to switch video mode 10 MULTI FUNCTIONAL CCTV TESTER 11 MULTI FUNCTIONAL CCTV TESTER ...

Page 7: ... 4V 3 7x2 Li Poly 2000mAh Charging Time 6 hour Operation Time 8 hour 2 4 TFT LCD Digital RGB666 320 x 240 10 50 L159 3 x W79 1 x T32 2 mm Video Mode Video IN LCD Adjustment CVBS Signal Mode HD SDI Format Communication PTZ Protocol Baud rate Rx Data Analyzer CVBS BNC IN 1 0 Vpp HD SDI HD TVI Brightness contrast NTSC PAL Auto adapt 720p 50fps 59 94fps 60fps 1080i 50fps 59 94fps 60fps 1080p 23 98fps ...

Page 8: ...umable item with 6 months warranty after purchase Use the manufacture provided adaptor only DC12V 1A When Red LED flicker reload battery or recharge battery L159 3 x W79 1 x T32 2 mm Tx Rx PWR CHG 159 3 66 5 63 8 79 1 32 2 FAR OPEN TELE OSD NEAR CLOSE WIDE COM V 300V 300V MAX V MODE SET 14 MULTI FUNCTIONAL CCTV TESTER 15 MULTI FUNCTIONAL CCTV TESTER After Operating with Power on On charging RED LE...

Page 9: ...in over 5 hours to fully charge The charged battery can operate for about 8 hours When the battery indicator shows below recharge it for use Full charge FUNCTIONS FUNCTIONS After the power is applied the above on screen message is displayed Approximately 2 seconds later the screen switches to the last OSD before power was turned off The Rapport mini HD stores the last accessed OSD The initial OSD ...

Page 10: ...he TELE key is pressed and decreases by 1 when the WIDE key is pressed Indicates SET Indicates OSD clear button Indicates Mode and changable by MODE button Indicates Current Video OSD clear FUNCTIONS FUNCTIONS Video Tester DC Adaptor connected Operated by Battery If there is no video signal at the VIDEO IN port of the Rapport mini HD LOSS will be displayed VIDEO NTSC BRI 3 CON 7 MODE CLR CVBS You ...

Page 11: ...witch video mode Press button to zoom in the HD SDI and HD TVI image VIDEO HD 1080p30 BRI 3 CON 7 MODE CLR HDTVI HD TVI VIDEO HD 1080i60 BRI 3 CON 7 MODE CLR HDSDI HD SDI image VIDEO HD 1080i60 BRI 3 CON 7 MODE CLR HDSDI Zoom in HD SDI image VIDEO HD 1080p30 BRI 3 CON 7 MODE CLR HDTVI HD TVI image VIDEO HD 1080p30 BRI 3 CON 7 MODE CLR HDTVI Zoom in HD TVI image Press button for 3 sec to select vid...

Page 12: ...tes type of test set up Resistance Voltage Continuity Buzzer Indicates test mode DCV DC Voltage ACV AC Voltage OHM Resistance BUZZ Continuity Indicates test value displayed Resistance Ω kΩ MΩ voltage V mV continuity BUZZ Indicates measured value on hold The measure value is stored and displayed here when the SET key is pressed Indicates Store button by using SET button Indicates measured graph val...

Page 13: ...esistance can be measured This current runs along all paths between the two test leads and enables the total resistance to be calculated Continuity Testing Continuity means the presence of a complete path for current to flow The continuity test features a beep that sounds when a circuit is complete The beep allows users to quickly test continuity without having to watch the display METER AC Ω DC V...

Page 14: ...Z Controller Connecting Camera and Monitor PTZ Operation Test Up Down Left Right Zoom and Manual focus control are possible The tester can also be set to various protocols and transmission speeds baud rates The PTZ SELECT menu is displayed when the PTZ key is pressed PTZ NTSC PTZ ADDR 001 PROTOCOL 01 PELCO D BAUDRATE 2 4Kbps PARITY NONE SPD 15 GPST 001 SPST 001 FUNC 01 MENU METER PTZ SETUP VIDEO D...

Page 15: ...complete press the key once more and the camera will move to the PRESET location SPST SET PRESET Sets and stores PRESET information in the range from 000 to 255 First move the camera to the required view and press the key and use the keys to place the cursor at the location of the chosen preset Then set up the address where the preset is to be stored by using the keys and press the key once more T...

Page 16: ...reen menu system that allows Rapport mini HD to program various functions of the camera including day night mode focus settings and tours When a tour is programmed into the camera it can be activated with Rapport mini HD using the TOUR function in the menu OSD Clear When you press ENTER button in the PTZ mode the PTZ OSD clear button is activated and press the button the PTZ OSD is cleard When you...

Page 17: ...V Indicates Current Mode Indicates remained battery Indicates received data CLEAR Clear the received data on the screen SET button operation DC Adaptor connected Operated by Battery SETUP Indicates Current Mode Indicates remained battery Indicates setup items DC Adaptor connected Operated by Battery Select a menu item by pressing the keys Each setup value can be changed by pressing the keys Mode S...

Page 18: ...ys Each setup value can be changed by pressing the keys ON OFF Number 1 2 3 4 5 6 7 8 9 10 11 12 13 Direct current Alternating current 3 Symbol Description Both direct and alternating current Three phase alternating current Earth ground TERMINAL PROTECTIVE CONDUCTOR TERMINAL Frame or chassis TERMINAL Equipotentiality On Supply Off Supply Equipment protected throughout by DOUBLE INSULATION or REINF...

Page 19: ...MEMO MEMO ...