WARMING DRAWER

Installation Information

2-2

INSTALLATION INFORMATION

The Wolf warming drawer is designed to be set into a built-in wall or cabinet installation.
This section of the manual covers some of the installation issues that a service technician may need to know when
servicing a Wolf warming drawer.  If additional installation information is needed after reviewing this section of the
manual, please refer to the installation guide or contact the Wolf Appliance Customer Service Department.

Electrical Requirements

• 110 to 120 Volts AC, 60Hz, 15 ampere fused electrical supply
• Separate electrical circuit serving only this appliance
• A properly grounded 3-prong receptacle

Line

Voltage

(Power)

Neutral

Ground

• 

TO AVOID SHOCK HAZARD, THE INSTALLATION SITE MUST BE EQUIPPED WITH A PROPERLY
GROUNDED 3-SLOT RECEPTACLE TO MATCH THE 3-PRONG (GROUNDED) POWER SUPPLY CORD
PROVIDED ON THE APPLIANCE.

• 

TO AVOID SHOCK HAZARD, NEVER REMOVE THE GROUND PRONG FROM THE PLUG OF THE POWER
SUPPLY CORD.  

Ground Prong

Figure 2-1.  Electrical Receptacle & Power Cord