background image

 

 

 
 

 

 

 
 
 

 
 

 

P.P.H. WObit E.K.J. Ober s.c. 
62-045 Pniewy, Dęborzyce 16 
tel. 61 22 27 422, fax. 61 22 27 439 
e-mail: [email protected] 
www.wobit.com.pl

 

 

User manual 

SDC107

 

DC motor driver up to 6A 

With speed, current and direction of rotation control

 

Summary of Contents for SDC107

Page 1: ...K J Ober s c 62 045 Pniewy D borzyce 16 tel 61 22 27 422 fax 61 22 27 439 e mail wobit wobit com pl www wobit com pl User manual SDC107 DC motor driver up to 6A With speed current and direction of rot...

Page 2: ...and solutions 10 5 Technical parameters 10 Thank you for selecting our product This instruction will help you at correct service and accurate exploitation of described device Information included in t...

Page 3: ...les of protection against the threats mentioned above provided that the device is used in a manner consistent with its purpose and that it is properly maintained The device can cause interference of s...

Page 4: ...tion using 6 switches on the front panel of the driver 5 V output for supplying an external potentiometer Optoisolated inputs for the activation ENABLE the direction DIR signals and the limit LIM N LI...

Page 5: ...driver it is recommended to use a power supply with an output voltage equal to the rated voltage of the motor used in the range of 12 36 V and current capacity appropriate to the motor power In the c...

Page 6: ...Activation of speed control from the internal potentiometer S2 POT MODE Current limit mode S3 SOFT START Soft start function S4 BRAKE STOP Braking function in the absence of ENABLE signal and limit si...

Page 7: ...soft start of the motor the delay in reaching the maximum speed is about 2 seconds Activation of the function may be necessary when controlling motors with more power or driving mechanisms with greate...

Page 8: ...used When S5 OFF it is for NO Normal Open sensors when S5 ON it is NC Normal Close sensors For 3 wire applications e g inductive use sensors with PNP output When using sensors with NPN output the LIM...

Page 9: ...signal input to ENABLE The motor moves in the direction depending on the signal at the DIR input After reaching the extreme position and activating the LIMIT N or P sensor the motor stops for about 3...

Page 10: ...OFT START function switch S3 ON The driver signals an error during braking For the active BRAKE STOP S4 ON mode braking returns energy from the motor to the power supply which may increase the power s...

Page 11: ...5 V 5 V max current consumption 100 mA Max Motor constant current 6 A Analog input 0 5 V IN 0 5 V input resistance 4 4k ohm Control inputs ENABLE DIR LIMIT N LIMIT P Optoinsulated low level 2 V high...

Reviews: