background image

 

1 / 11 

 

 

Note: 

On the cover sheet you can find warning information, and an explanation 
of

and 

symbols

 

the

 

terms used, together with the exclusion of liability. 

 

Contents

 

General ........................................................................................................................... 2

 

Code length / silent alarm ............................................................................................ 2

 

Battery ......................................................................................................................... 2

 

Interfaces .................................................................................................................... 2

 

Du delay time ................................................................................................. 2

 

Penalty time ................................................................................................................. 2

 

Overview of user rights ................................................................................................ 3

 

Open ............................................................................................................................... 3

 

Opening with Dualcode ................................................................................................... 3

 

Opening with active delay time ........................................................................................ 4

 

Triggering a silent alarm .................................................................................................. 4

 

Menu functions ................................................................................................................ 5

 

0 Change code ............................................................................................................ 5

 

1 Create user ............................................................................................................... 5

 

2 Blockade .................................................................................................................. 6

 

3 Delete user ............................................................................................................... 6

 

5 Check system ........................................................................................................... 6

 

6 System setup ............................................................................................................ 7

 

6-1-1 Mode change UART, serial communication .................................................... 7

 

6-1-2 Switch off analog keypad ................................................................................ 7

 

6-1-3 Activating the analog keypad and UART ........................................................ 8

 

6-2 Configuration of silent alarm .............................................................................. 8

 

6-3 Activate / deactivate external system blockade .................................................. 9

 

6-4 (De)Activate Dualcode ....................................................................................... 9

 

6-5 Battery warning threshold .................................................................................. 9

 

7 Overview of users ................................................................................................... 10

 

8 Activate setup mode ............................................................................................... 10

 

9 Set delay ................................................................................................................ 11

 

 

 

Operator

Instructions

 

administrators

 

user

 

and

 

system

 

for

 

 

Manual

 

 

4000

Wittkopp

 

Anchor

 

Summary of Contents for ANCHOR

Page 1: ...gering a silent alarm 4 Menu functions 5 0 Change code 5 1 Create user 5 2 Blockade 6 3 Delete user 6 5 Check system 6 6 System setup 7 6 1 1 Mode change UART serial communication 7 6 1 2 Switch off analog keypad 7 6 1 3 Activating the analog keypad and UART 8 6 2 Configuration of silent alarm 8 6 3 Activate deactivate external system blockade 9 6 4 De Activate Dualcode 9 6 5 Battery warning thres...

Page 2: ...the battery as soon as possible The programmed codes are retained while the battery is changed Interfaces As supplied only the interface for analog input units from the Primor series is active Other interfaces must be set via the Setup menu Dualcode delay time If Dualcode has been activated the opening operation corresponds to the described opening procedure after the end of the delay time Only us...

Page 3: ...ser 3 begins the input of his code with code 030303 If there is an incorrect input or if more than 30 seconds elapse between the two code inputs then the inputting is terminated with a long signal tone The two pairs of eyes principle here user 5 with code 0505050 initiates the opening operation Factory code Open Start delay time Quick opening code Create user Change code Delete user Initiate opera...

Page 4: ...me 2 sec 2 sec 2 sec 1 sec 1 sec 1 sec Input the code for opening Triggering a silent alarm e g opening code 1234567 alarm addend 2 Start through code input The last code digit is amended in each case with active silent alarm The calculation is done on the basis of the last digit alarm addend If a number is carried over then the units are evaluated e g code number 9 alarm addend 2 11 hence the las...

Page 5: ...create user No 3 Menu Create user Input the master code A new user code is only accepted if the code differs at two places by one digit from an existing code If an opening delay has been programmed user 9 for the immediate opening code can only be created in the opening release time This of course only applies if this had not already been created before the activation of the delay time Number of t...

Page 6: ...a user It is not possible to delete the master Number of the user to be deleted 5 Check system Checking the menu system Press the keys in the sequence Press each numeric key once A functional key is indicated by a double signal tone A key that is not recognised is indicated by a long signal tone and the function test is terminated The system must be checked If Dualcode is active the user who made ...

Page 7: ...he master code Warning Once the analog keypad has been switched off it can only be activated again via the serial interface Since switching of the operating mode can under certain circumstances also have a major influence on the function of the input unit the general sequence for the menu function was amended intentionally This should make it more difficult to switch mode accidentally Submenu Mode...

Page 8: ...git 3 Menu System setup Input the master code The silent alarm function is deactivated by inputting the number 0 as the alarm addend The quiescent state of the switching contact is defined by the switching logic high relay switches on briefly if there is an alarm low relay switched to quiescent state If there is an alarm it is switched off briefly Submenu silent alarm Alarm addend Switching logic ...

Page 9: ...vate Dualcode Activate deactivate the Dualcode Menu System setup Input the master code The Dualcode only becomes active once at least a second user has been defined A valid opening code must be input before the menu start to be able to deactivate the function Submenu Dualcode activate 1 deactivate 0 or 6 5 Battery warning threshold Amend the battery warning threshold to for example 5 67 V Menu Sys...

Page 10: ...ady been created User number to be checked free occupied End the query 8 Activate setup mode Menu Activate setup mode Input the master code Setup mode is used to parametrise the functions Create user Delete user or delay times Submenu Setup mode Setup mode is terminated automatically if keypad input is cancelled due to the time being exceeded at the end of a menu sequence without restarting a menu...

Page 11: ...eased at any time A reduction or a deactivation of the opening delay time is only possible during the release time To deactivate the delay set the delay time to 00 and the release time to 01 Range of values Delay time 01 to 99 minutes Release time 01 to 19 minutes Set the delay time Release time Confirm the delay time Confirm the release time ...

Reviews: