background image

90 DAY LIMITED WARRANTY

 

 Winegard Company warrants this Winegard product against any defects in materials or workmanship 

within 90 (ninety) days from date of purchase. No warranty claim will be honored unless at the time 

the claim is made, you present proof of purchase to an authorized Winegard dealer (if unknown, 

please contact Winegard Company, 3000 Kirkwood Street, Burlington, IA 52601-2000, Telephone 

800-288-8094).
  Winegard Company (at its option) will either repair or replace the defective product at no charge to you. 

This warranty covers parts, but does not cover any costs incurred in removal, shipping or reinstallation 

of the product. This limited warranty does not apply if the product is damaged, deteriorates, malfunctions 

or fails from: misuse, improper installation, abuse, neglect, accident, tampering, modification of the 

product as originally manufactured by Winegard, usage not in accordance with product instructions 

or acts of nature such as damage caused by wind, lightning, ice or corrosive environments such as 

salt spray and acid rain.
  The 90 Day Warranty is provided on the condition that the equipment is properly delivered with all 

handling and freight charges prepaid to your Winegard dealer for return to our factory for repair or 

replacement. Winegard dealers will arrange for the replacement or repair and return to you without 

charge the product which failed due to defective material or workmanship.
  WINEGARD COMPANY WILL NOT ASSUME ANY LIABILITIES FOR ANY OTHER WARRANTIES, 

EXPRESS OR IMPLIED, MADE BY ANY OTHER PERSON.
  ALL OTHER WARRANTIES WHETHER EXPRESS, IMPLIED OR STATUTORY INCLUDING 

WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY ARE 

LIMITED TO THE 90-DAY PERIOD OF THIS WARRANTY.
  The foregoing shall be the sole and exclusive remedy of any person, whether in contract, tort or 

otherwise, and Winegard shall not be liable for incidental or consequential damage or commercial 

loss, or from any other loss or damage except as set forth above.
  Some states do not allow limitations on how long an implied warranty lasts, or the exclusion of 

limitation of incidental or consequential damages, so the above limitations or exclusions may not 

apply to you.

  This warranty gives you specific legal rights and you may also have other rights which vary from 

state to state.

Printed in U.S.A.  © 2004, 2006 Winegard Company    Rev6 10-16  2451966

SENSAR

® 

TV ANTENNA

Amplified Model GS-2200

Non-amplified Model GS-1100

Made in U.S.A.

U.S. Patent No. D500,496

Rev. 2/08

HOW TO PROVIDE 
LIGHTNING PROTECTION 
FOR TV ANTENNA  AND SET

Step 1. 

Mount the lightning arrestor or 

75 ohm coaxial grounding block as close 
as possible to where the 75 ohm coaxial 
cable downlead enters the house. 

Step 2. 

The ground wires for both the 

mast and the downlead should be copper 
or aluminum wire, number eight (8) or 
larger. 

Step 3. 

The downlead wire from the 

antenna to the lightning arrestor and the 
mast ground wire should be secured to 
the house, spaced from four (4) to six (6) 
feet apart. 

NOTE:

 In the case of a “ground up” an-

tenna installation, it may not be necessary 
to ground the mast if the mast extends 
four or more feet into the earth. Consult 
a TV serviceman for the proper depth in 
your location. 

Point the front of the antenna (with Winegard logo)  

at broadcast towers of stations you want to receive.

Register your product at winegard.com/myantenna

         NOTE:

 

 

THE AMPLIFIED GS-2200 ANTENNA NOW IS POWERED BY A 5 VDC POWER 
ADAPTER (INCLUDED). PREVIOUS MODELS MAY HAVE RUN ON 12 VDC, 
IF REPLACING A PREVIOUS MODEL THE POWER ADAPTER AND INSERTER 
WILL ALSO NEED REPLACED.

         

WARNING:

 

INSTALLATION OF ANTENNAS NEAR POWER LINES IS DANGEROUS. 
FOR YOUR SAFETY, FOLLOW THE INSTALLATION INSTRUCTIONS. 
TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE POWER 
SUPPLY TO RAIN OR MOISTURE.

Antenna Lead

In Wire

Ground

Clamp

Electric

Service

Equipment

Antenna

Discharge Unit

(NEC Section 810-20)

Power Service Grounding

Electrode System

(NEC Art 250, Part H)

Ground 

Clamps

Grounding Conductors

(NEC Section 810-21)

NEC - National Electrical Code

Example of antenna grounding as per

National Electrical Code, ANSI/NFPA 70

(May substitute a 75 ohm 

Coax Grounding Block)

LIGHTNING PROTECTION

 - 

Example of 

Antenna Grounding (as per National Electrical  

Code, ANSI/NFPA 70)

NEC – Nation Electrical Code

Antenna  

Downlead Wire

Ground  

Clamp

Electric 

Service 

Equipment

Antenna Discharge Unit 

(NEC Section 810-20). 

May substitute a 75 ohm 

coax grounding block

Grounding 

Conductors (NEC 

Section 810-21)

Ground Clamp

Power Service Grounding Electrode System 

(NEC Art 250, Part H)

2451966 

Rev6 10-16  