background image

 

 

                                                                

 

 
 
 
 
 
 

INSTALLATION AND OPERATION MANUAL 

 
 
 
 
 
 
 

WIKA 

WMI

 Series Magnetic Level Indicator 

 

(Please retain for future usage) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Contact: 
 

WIKA Instrument Corporation 
950 Hall Court 
Deer Park, TX 77536 

www.wika.com

 

1-800-570-4454 

Summary of Contents for WMI Series

Page 1: ...NSTALLATION AND OPERATION MANUAL WIKA WMI Series Magnetic Level Indicator Please retain for future usage Contact WIKA Instrument Corporation 950 Hall Court Deer Park TX 77536 www wika com 1 800 570 4454 ...

Page 2: ...e measured As the liquid level increases and decreases in the chamber the float rises and falls with the liquid level This float contains a magnet assembly The force or flux of the magnet assembly contained in the float affects a visual indicator mounted outside of and isolated from the float chamber This same magnetic force can also affect optional switches or transmitters mounted outside of the ...

Page 3: ...he shipping container carefully inspect each instrument to ensure that it has arrived complete and ready for installation Note that the process conditions are listed on the tag mounted at the base of the indicator assembly Make sure that these process conditions match the application for which this gauge is designed Should there be damage to The WMI Series Magnetic Level Indicator try to take digi...

Page 4: ...on valves between the Level Gauge and the process tank This will allow for gradual pressurization of the Level Gauge chamber as well as facilitate any future maintenance necessary The gauge should be mounted level to ensure proper float travel without friction The WIKA WMI Series Magnetic Level Indicator arrives complete with the float installed No further assembly should be required Included with...

Page 5: ...ction entitled Maintenance to learn the proper procedure for removing this instrument from service Functional Test The best way to provide a functional test for this instrument is to raise and lower the level of the material in the tank and therefore the gauge Many times this is not possible If this is the case utilize one of the following options 1 Make sure the chamber is isolated from process c...

Page 6: ...the gauge Caution Take care to not allow the float to drop on the floor This can cause damage to the float and or the magnet assembly 5 Clean out chamber with a brush and wash with water if compatible Make sure there are no remaining solid particles Look for items or debris that will inhibit the movement of the float Further inspect the gauge chamber to ensure that it is free from unexpected corro...

Page 7: ...f its use Seller makes no warranties as to the equipment manufactured by it which extend beyond the description of such equipment on the face hereof WIKA Instruments Corporation s obligation to correct defects in such equipment by repair or replacement in accordance with the foregoing provisions is in lieu of any other warranties expressed or implied as to such equipment WIKA Instruments Corporati...