background image

LASS.PS.4A

 051515

The Coolest Thing In Wine Storage

Cold Weather Start Kit:

To be used in conjunction with 

Platinum Split 4000 (Manufactured 

After 01/07/15)

 cooling system. 

COLD WEATHER 

START KIT

Platinum Split 4000

Summary of Contents for Platinum Split 4000

Page 1: ...PS 4A 051515 The Coolest Thing In Wine Storage Cold Weather Start Kit To be used in conjunction with Platinum Split 4000 Manufactured After 01 07 15 cooling system COLD WEATHER START KIT Platinum Split 4000 ...

Page 2: ...OOL is not responsible for printing or clerical errors WhisperKOOL reserves the right to make corrections or improvements to the information provided and to the related hardware at any time without notice Vinothèque and WhisperKOOL are registered trademarks and ECE is a trademark of WhisperKOOL All rights reserved Mention of third party products is for informational purposes only and constitutes n...

Page 3: ... com Page 1 TABLE OF CONTENTS Receiving Inspecting the System 3 Before You Start 4 Condensing Unit Cold Weather Start Kit Installation Instructions 5 Evaporator Unit Cold Weather Start Kit Installation Instructions 21 ...

Page 4: ...Manual carefully and keep it for future reference What is a Cold Weather Start Kit The Cold Weather Start Kit is designed to insure the start of your cooling system despite frigid ambient temperature that may result in failure of unit operation The Cold Weather Start Kit will provide heat to the condensing unit when ambient temperature is too low How Does the Cold Weather Start Kit Work The Cold W...

Page 5: ... license to build your wine cellar 6 Warranty is not active until a Warranty Checklist has been received reviewed and approved RECEIVING INSPECTING THE SYSTEM After verifying that you have received all of the correct components for your specific system please keep the Cold Weather Start Kit in its original box until you are ready for installation This will allow you to move the product safely with...

Page 6: ...Power going to the Evaporator and Condensing Unit WARNING Failure to do so may cause electrical shock which can result in injury or death A 2 wire 18 20 awg thermostat wire will need to be ran from the evaporator unit to the condensing unit prior to installing the Cold Weather Start Kit Review the Tools Needed and Components Provided document prior to starting ...

Page 7: ...backing from the paper jig and stick to the side of the existing electrical box as shown The cross should be slightly offset to the right Using a step bit drill a 5 8 hole through the cross Be sure not to drill into the electrical components Route the 4 wires from the Cold Weather Start Kit box into the existing electrical box as shown 1 2 3 4 ...

Page 8: ...uble sided tape as shown Remove the backing on the double sided tape as shown Line up the back of both boxes and stick the Cold Weather Start Kit box the condensing unit and existing electrical box Cut the 3 zip ties around the hot and neutral wires off as shown 5 6 7 8 ...

Page 9: ...kool com Page 7 Reorganize wires in H lever connector as shown Reorganize wires in N lever connector as shown Secure the 6 wire into the H2 lever connector Secure the 7 wire into the H2 lever connector 9 10 11 12 ...

Page 10: ...re the 5 wire into the N lever connector Secure the 8 wire into the H lever connector Remove the blue flag connector from the 1 terminal on the Delay on Break Timer Cut the blue flag terminal off the black wire from the previous step 13 14 15 16 ...

Page 11: ... 8 Crimp the yellow female disconnect labeled 1 onto the 11 wire and the black wire from the previous step Connect the yellow female disconnect labeled 1 to the 1 terminal on the Delay on Break Timer Disconnect the yellow female disconnect from the 3 terminal on the Delay on Break Timer 17 18 19 20 ...

Page 12: ...es from the previous step Strip the ends of each of the two wires from the previous step to a length of 3 8 Crimp the red female disconnect labeled 3 onto the black wire from the previous step Connect the red female disconnect labeled 3 to the 3 terminal on the Delay on Break Timer 21 22 23 24 ...

Page 13: ... blue wire from 3 steps ago with the 10 wire Crimp the closed end terminal onto the 10 wire and the blue wire from the previous step Locate the silicone heater assembly Loosen the two screws on the cord squeeze on the existing electrical box 25 26 27 28 ...

Page 14: ... white wires from the silicone heaters up into the electrical box Twist the strands of each heater wire together Secure the two heater wires into the N Lever connector Route the 9 wire with the red disconnect labeled T down through the cord squeeze 29 30 31 32 ...

Page 15: ...ine up silicone heater wires with the stud on the back of the fan motor The top of the heater should be 2 5 from the top of the receiver Remove the backing from the other silicone heater Line up the back edge of the second heater with the back edge silicone heater already on the receiver and stick into place 33 34 35 36 2 5 ...

Page 16: ... the silicone heaters as shown Slide the thermal switch assembly over the top of the receiver as shown Secure the blue female disconnect labeled T onto the bottom terminal of the thermal switch Secure the red female disconnect labeled T onto the top terminal of the thermal switch 37 38 39 40 ...

Page 17: ...al switch and heater wires as shown 5x Zip tie wires in locations shown Route the 24v thermostat wires through the cord squeeze into the electrical box 41 42 43 Remove the 4 Phillips head screws on the Cold Weather Start Kit Electrical Box 44 ...

Page 18: ...Kit Electrical Box Route the 24v thermostat wire through the hole in the boxes into the Cold Weather Start Kit Electrical Box Connect one of the 24v thermostat wires to the 13 wire using the wire nut provided Connect the 24v thermostat wire to the 12 wire using the wire nut provided 45 46 47 48 ...

Page 19: ...ided self taping screws secure the 24V coil relay to the Cold Weather Start Kit box through the predrilled holes Failing to use the provided screws and mounting locations may result in a punctured coil Tuck wires in electrical box as shown Make sure that the Bypass Timer is set to 1000 seconds 49 50 51 52 ...

Page 20: ...4A 051515 Make sure that the Delay On Break relay is set to 5 minutes Secure the 2 screws on the cord squeeze Secure both tops back onto the electrical boxes using the removed screws Cut the corner of the bag off as shown 53 54 55 56 ...

Page 21: ... flat surface of the thermal switch Be sure the thermal switch is making good contact with the receiver under the ridge 57 58 The Cold Weather Start Kit has been successfully installed on the condensing unit next proceed to the evaporator unit instructions ...

Page 22: ...Page 20 1 800 343 9463 LASS PS 4A 051515 NOTES ...

Page 23: ...Kit All parts for the Evaporator Unit are located inside of this box Open box and remove the 24v transformer and the zip lock bag The kit will include five zip ties four lever connectors one 6 32 kep nut and one 120v 24v step down transformer Using a Phillips head screw driver loosen the 2 Phillips head screws on the front panel Note The screws do not come out of the panel 1 2 3 4 ...

Page 24: ...a Phillips Head Screw driver loosen the 4 screws on the ducting panel make sure screw comes all the way out of the housing of the unit Note The screws do not come out of the panel Pull ducting panel away from the unit to remove it Remove the panel Remove the thumbscrew by rotating it counter clockwise Set thumbscrew aside for later use 5 6 7 8 ...

Page 25: ...nd side edges of the transformer Place flange of the transformer between the control box and the flange of the electrical panel place the other flange underneath the grommet Press transformer firmly in place Locate one of the white wires coming out of the push connector Cut one white wire and strip both ends to a length of 3 8 9 10 12 13 ...

Page 26: ...ctor Locate the blue wire coming out of the Molex connector Cut the blue wire and strip each end to a length of 3 8 Secure the blue wires from the unit and the black wire from the transformer into a lever connector Secure one of the t stat wires and the blue wire coming from the 24v side of the transformer into a lever connector 14 15 16 17 ...

Page 27: ...ide of the transformer into a lever connector Zip tie wires in locations shown Slide the electrical panel back into place and re install the thumb screw Wall Mounted Units Secure one of the t stat wires and the blue wire coming from the 24v side of the transformer into a lever connector 18 19 20 21 ...

Page 28: ...ly installed on the Evaporator Unit If the installation process is complete on the condensing unit as well plug both the condensing unit and evaporator units back into a power source Ducted Units Push ducting panel back on unit and tighten the 4 screws on the ducting panel to the unit 22 ...

Page 29: ...LASS PS 4A 051515 NOTES ...

Page 30: ...LASS PS 4A 051515 WhisperKOOL 1738 E Alpine Ave Stockton CA 95205 1 800 343 9463 www whisperkool com ...

Reviews: