background image

 
 
 
 
 
 
 
 
 
 

 

Service & Installation manual 

 

Light programmable oven with 

boiler 

 

Summary of Contents for Light programmable oven

Page 1: ...Service Installation manual Light programmable oven with boiler ...

Page 2: ...ven set up 15 17 Set up mode U1 to U9 16 Set up mode U10 to U15 17 Test functions 18 23 Test mode D0 to D6 19 Test mode D7 to D15 20 Test mode D16 to D20 22 Test mode D21 to D28 23 Test mode D29 to D47 24 User menu 25 29 User menu B1 to B6 26 User menu B7 to B12 27 User menu B13 to B20 28 User menu B21 to B24 29 Error codes 30 Survey of error codes 31 Appendices 32 34 Appendix 1 WHIRLPOOL installa...

Page 3: ... registered on the WHIRLPOOL website your new WHIRLPOOL oven is covered by a 48 month factory warranty The warranty covers the oven cabinet and spare parts Furthermore there is a 10 year warranty on the exterior door glass The period of warranty takes effect from the date of production For further information on the warranty terms please visit www houno com warranty The warranty does not include W...

Page 4: ... communicating with WHIRLPOOL we kindly ask you inform us of the serial number of the oven that is stated on the approval plate The approval plate is located on the right hand corner post of the oven cabinet as shown below ...

Page 5: ...e oven or from the motor side Note that the oven can be lifted off the stand Remove the original packaging from the oven Do not remove the foil that covers the surfaces until the oven has been installed as once the foil has been removed the surfaces are vulnerable to sharp objects such as tools Remove all packaging material that secures the racks in the oven chamber The packaging should be destroy...

Page 6: ...from the rear wall and the distance between the right side of the oven and the nearest wall or piece of furniture etc should be at least 7 cm 2 75 inch This is to ensure the necessary flow of cooling air to the oven Strong sources of heat such as hotplates tilting frying pans deep fat fryers etc should not be placed near the oven otherwise the warranty may cease to apply NSF On an oven with stand ...

Page 7: ...rd to ClimaOptima calibration and cooling of the oven may occur Ovens with a steam generator must not be connected to a reversed osmosis plant as this may cause problems with the reading of the water level in the steam generator The water connection must be carried out by an authorised plumber in accordance with existing rules and regulations Clogged up water filters and dirt in the solenoid valve...

Page 8: ...ed down with cold water or when the oven chamber is cleaned Connection must be carried out by an authorised plumber to an open or to a closed drain It is recommended that a water outlet is available established in the floor of the room where the oven is located The drain must never end directly beneath the oven The drain must be of stainless steel or an equally temperature resistant material have ...

Page 9: ...sections in mm 382 395 382 395 AFO Æ 375 388 375 388 376 377 378 389 390 391 376 377 378 389 390 391 379 392 379 392 380 393 380 393 383 396 383 396 384 397 384 397 9 kW Fuse 18 kW Fuse 24 kW Fuse 36 kW Fuse 27 kW Fuse 60 kW Fuse 400V 3N 50 60 Hz 5x2 5 16A 5x4 35A 5x10 50A 5x10 63A 5x10 50A 5x25 100A 400V 3 50 60 Hz 4x2 5 16A 4x4 35A 4x10 50A 4x10 63A 4x10 50A 415V 3N 50 60 Hz 5x2 5 16A 5x4 25A 5x...

Page 10: ...raction funnel can be ordered from WHIRLPOOL The scope of supply also includes a specially designed extraction hood see illus below If an extraction hood is installed in the ceiling above the oven it should project 50 cm over the front of the oven The suction effect should be 400 800 m3 h The ventilation motor can be controlled directly from the oven This means that the ventilation starts when a p...

Page 11: ...and shower Check for correct electrical connection Check connection to drip tray Check for correct mounting of drip tray Check for correct fall of hose from drip tray and check for leaks Check for correct exhaust and drain connection Clean oven Apply steel oil Oven chamber Check that filter housing is mounted correctly Check interior light Clean oven Operation panel Check and adjust if necessary e...

Page 12: ...ng Calibrate door sensor 3 Inside Interior light Jets may need cleaning Fan should rotate freely and be tightly fitted Heating element may need tightening 4 Under oven Drain system check for leaks and blocks Condensation jet and drain sensor Drip tray clean hose for discharge connection piece Drip slide on oven door 5 Motor room Connection to heating elements Load distribution on phases Wire conne...

Page 13: ...e intervals 12 month inspection Follow the annual service check see above Change Door seal Light bulbs Gasket for lamp glass Nozzles Bearing for nozzle arm Update software 24 month inspection Follow the annual service check see above Change Door seal Light bulbs Gasket for lamp glass Nozzles Main contactor Spring for handle Bearing for nozzle arm Update software 36 month inspection Follow the annu...

Page 14: ...ime flashes set injection time with turn switch B model only Change oven temperature with turn switch Change time with turn switch Core temperature on C and K models Injection time on B model Program key Step key HOT AIR selected if control lamp on COMBI STEAMING selected if upper or middle control lamp is on REHEATING is selected if lower control lamp is on Steaming on C and K preheating on B Exh...

Page 15: ...f the computer control of the oven model in question The program display shows a description of the U function in question Display shows setting Not active Display shows U No Display shows description of U function Display shows setting Press HOT AIR and STEAMING for 2 sec Possible to change to d test mode with combi steam key Press STEAMING PREHEATING and HOT AIR for 2 sec Not active Not active C...

Page 16: ...current temperature by pressing the temperature key 0 OFF 1 ON When you have chosen the temperature scale confirm by pressing the alarm key if the control lamp flashes After that the controller initialises NOTE ALL settings and programs are reset U5 Not in use U6 Low temperature steaming You activate and deactivate low temperature steaming by pressing the step key 0 OFF steaming only possible at 1...

Page 17: ...vate and deactivate drain cooling by pressing the step key 0 OFF 1 ON U13 Timer start You activate or deactivate timer start by pressing the step key 0 OFF 1 ON U14 Demo You activate or deactivate the demo mode by pressing the step key 0 OFF 1 ON NOTE If the demo mode is on 1 ON the oven will run without heating elements and steam generator being switched on When the oven starts it will let you kn...

Page 18: ...G Not active Not active Possible to choose a d function with turn switch Main switch Not active Test Mode To enter test mode press hot air key and combi steam key for 2 sec To exit test mode turn switch left Change between set up mode and test mode by pressing steaming preheating key How to operate the selected component You turn the component on 1 and off 2 by pressing the step key Or you press t...

Page 19: ...on by pressing the step key However this function can only be activated when there is water in the steam generator To pulse press the alarm key 0 OFF 1 ON D3 Fan right hand high low This function activates the frequency exchanger You can test the speed of the motor by pressing the step key 0 OFF 2 ON By pressing the time key it is possible to adjust the speed of the motor from 0 to 100 The RPM app...

Page 20: ...off OFON outlet 4 is off and outlet 5 is active ONON both outlets are active You activate or deactivate the function by pressing the step key 0 OFOF 1 OFON 2 ONOF 3 ONON D12 Cooling fan This function activates motors M7 and M7A You activate or deactivate the function by pressing the step key To pulse press the alarm key 0 OFF 1 ON D13 Buzzer This function activates buzzer H2 You activate and deact...

Page 21: ... the temperature press the time key until the digit in the display flashes Then adjust upwards or downwards until the correct temperature is shown Finally press the time key again to save the setting The temperature can be adjusted by 10 C D18 Drain temperature Here it is possible to read the current steam generator temperature P4 In the field next to Temperature the current temperature is shown I...

Page 22: ...ch is why there is only one input signal D23 Thermo switch fan Here it is possible to read the status of S2 and S2A In the display next to Time it is shown whether the circuit is connected or disconnected OF disconnected ON connected In the event of defects wait for 10 20 minutes then try again Note Q2 is only found in ovens with 2 fan motors 1 16 and 1 20 S1 and S1A each have their own input on t...

Page 23: ...le to reset thermo switch Q3 which is located at the bottom of the oven below the operation panel D37 Motor RPM 1 Here it is possible to read the number of revolutions for fan motor 1 The number of revolutions is shown in the display next to the temperature key D38 Motor RPM 2 Available on 1 16 and 1 20 models only Here it is possible to read the number of revolutions for fan motor 2 The number of...

Page 24: ...setting Not active Not active Not active Not active Not active Press key for 5 sec to access user menu Turn switch Main switch Start Stop User Menu To enter user menu press alarm key for 5 sec To exit user menu turn the switch to the left The user menu can be operated by the end customer as well as by the service engineer ...

Page 25: ...und level high In this function you adjust the sound that comes from the alarm The sound level can be adjusted from 1 to 9 1 is very low You adjust the sound by pressing the step key B5 Sound frequency In this function you adjust the sound frequency The sound frequency can be adjusted from 1 to 9 You adjust the sound by pressing the step key You test the sound by pressing the alarm key B6 Interior...

Page 26: ...temperature display digit flashes 2 Turn the switch to the desired setting of hours 3 Press the key next to the temperature display digit stops flashing You can set the hours from 0 to 23 The oven s clock may appear as screen saver B12 Day weekday In this function you set the day of the month and of the week 1 Press the key next to the temperature display digit flashes 2 Turn the switch to the des...

Page 27: ...ext to the temperature display digit flashes 2 Turn the switch to the desired time 3 Press the key next to the temperature display digit stops flashing You set the time from 2 to 50 sec B18 Pulsing interval Combi Steam 2 In this function you adjust the pulsing time for Combi Steam 2 1 Press the key next to the temperature display digit flashes 2 Turn the switch to the desired time 3 Press the key ...

Page 28: ... variants A B see below A B 1 DANISH ENGLISH 2 ENGLISH CROATIAN 3 SWEDISH SLOVENE 4 FINNISH ESTONIAN 5 GERMAN HUNGARIAN 6 SPANISH RUSSIAN 7 FRENCH CZECH 8 ITALIAN 9 DUTCH To change the language you need to update again see B24 B24 Software update In this function you update the computer software by means of a special memory key not a USB key 1 Insert memory key 2 Press alarm key to view software v...

Page 29: ... 29 Error codes All keys can be used to acknowledge an error message Display shows error Er No Display shows description of error Turn switch Main switch Start Stop ...

Page 30: ...o hot Temperature in steam generator higher than 130 C If fault recurs descale generator Error code 14 FAN SPEED Fan running too slow Error code 15 CPU HOT CPU board too hot 60 C Error code 16 IO BRD HOT IO board too hot 60 C Error code 18 DATA ERROR Error in set up data Error code 19 WRONG LANG Wrong language Error code 20 NO COM IO Internal defect Failure in communication between computer and IO...

Page 31: ...e of installation ________________ _____ __________ The installation was carried out not carried out on the basis of the requirements specified in the service and installation manual please tick If the measurements do not correspond with the values stated in the service and installation manual your WHIRLPOOL distributor should be notified We confirm that the installation has been carried out on th...

Page 32: ...or 5 CombiPlus fitted with open drain for both ovens The drain must never end directly under the oven Voltage and water supply Please insert the measured value Voltage measured at Water pressure measured at min 2 bar 28 5 psi max 6 bar 88 psi Does the voltage on site comply with the voltage stated on the approval plate Dirt filter fitted Function test All electrical connections are tight All water...

Page 33: ...____________________________________ Fax _____________________________________ E mail address ____________________________ Serial no _________________________________ Instruction carried out by __________________________________________ Date of instruction _________________ _____ __________ Please tick the appropriate box The customer has been instructed in the manual use and programming of the ov...

Page 34: ..._______________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ ________________________________________________________________________...

Page 35: ..._______________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ _________________________________________________________________________ ________________________________________________________________________...

Reviews: