WESTLAB

EXTREME MONOCULAR

MICROSCOPE,

RECHARGEABLE, LED

CODE 663-540 & 664-089

USER MANUAL

INSTRUCTION

MANUAL

Before Use

1

1.Nomenclature

2

2.Operation

3

2-1 Set the Specimen Slide

3

2-2 Set Illumination

3

2-3 Adjust Focus

3

2-4 Adjust Diaphragm

3

2-5 Choose the Objective

3

2-6 Change the Lamp

3

3.General Specification

4

4.Parameter/Technical Terms

5

5.Troubleshooting

7

*Please read these instructions

carefully before use.

Summary of Contents for 663-540

Page 1: ...ER MANUAL INSTRUCTION MANUAL Before Use 1 1 Nomenclature 2 2 Operation 3 2 1 Set the Specimen Slide 3 2 2 Set Illumination 3 2 3 Adjust Focus 3 2 4 Adjust Diaphragm 3 2 5 Choose the Objective 3 2 6 Ch...

Page 2: ...cially the plastic parts should be cleaned with a neutral detergent 3 Do not take down or assemble it yourself 4 After use cover the microscope with the dustcover provided and keep it in a dry and cle...

Page 3: ...2 1 NOMENCLATURE Iris WESTLAB EXTREME MONOCULAR MICROSCOPE RECHARGEABLE LED USER MANUAL CODE 663 540 664 089...

Page 4: ...s Then lock the limit stop screw to avoid impact between the objective and slide Adjust the fine focusing knob to get the image sharper and clearer 2 4 Adjust diaphragm Turn the disc diaphragm to sele...

Page 5: ...d Monocular head 360 rotating Binocular head 360 rotating Metal base and stand Binocular head 360 rotating Metal base and stand 110mmX120mm Built in movable stage 125mmX130mm Triple nosepiece Quadrupl...

Page 6: ...options 4 4 PARAMETER 1 Total magnification 20X 1600X 2 Field of view 0 08 4 5mm 3 Mechanical tube length 160mm 4 Object to primary image distance 195mm 220V 240V power supply 220V 240V 10 50 60Hz Lam...

Page 7: ...he n is the refractive index of the medium air or immersion oil between the cover glass of the objective and the specimen The is the half of the aperture angle The N A is bigger the resolution of the...

Page 8: ...men faces down The immersion oil has accumulated on the dry objective The immersion oil is not used for oil objective 100XR Air bubble in the immersion Use wrong immersion oil The aperture is not open...

Page 9: ...es the cover glass when turning the nosepiece The cover glass faces down Put the cover glass to face up Use a standard cover glass with thickness of 0 17mm The cover glass is not standard 3 Cannot mov...