background image

 

Document: 1864en03.doc 

 

WESTERSTRAND 

Author: TAn 

 

Date: 2012-01-18 

 

 

Page: 1 of 15 

 
 
 
 
 

 
WESTERSTRAND URFABRIK AB 

 

 

 

P.O. Box 133 

Tel. +46 506 48000 

 

Internet::  http://www.westerstrand.se 

SE-545 23  TÖREBODA 

Fax. +46 506 48051 

 

E-mail: 

 [email protected]

 

 

 
 
 
 
 
 
 
 
 
 

 
 

 

 

 

 

 

Instructions 

Digital clock, Lumex 5 

 

DATEX 

 

Summary of Contents for Lumex 5

Page 1: ...D Author TAn Date 2012 01 18 Page 1 of 15 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Instructions Digital clock Lumex 5 DATEX ...

Page 2: ...l as time reference as a slave clock to a master clock transmitting 24 V polarised 1 1 minute impulses or synchronised by TC DCF The clock can be set for different language and nation see programming The clock is changing summer and winter time the last Sunday in March and the last Sunday in October automatically The clock has adjustable light intensity If power failure occurs the display is turne...

Page 3: ...n you have R F P buttons to the right Remove the front Mount the 2 holder at the digital clock and mount it If operated by synchronisation check the strapping according to the drawing page 6 Connect the cables according the schema page 4 and page 5 Connect the power 230VAC 50Hz according the schema page 4 When the clock is permanently installed a readily accessible disconnect device shall be incor...

Page 4: ...n Date 2012 01 18 Page 4 of 15 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Connection The connections are made at the back plate see below ...

Page 5: ...f 15 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Connection Synchronisation wire TC MIN imp 3 4 DCF 2 line 3 V 5 GND DCF 3 line 3 V 4 DCF 5 GND Sync input 1 2 3 4 5 ...

Page 6: ...5 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Strapping DIP switch setting for TC MIN impulse default Strapping DIP switch setting for DCF radio 2 wire computer board ...

Page 7: ... Date 2012 01 18 Page 7 of 15 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Strapping DIP switch setting for DCF radio 3 wire computer board ...

Page 8: ...t minute impulse The clock will be synchronised Slave mode Set the clock for slave mode InSL See programming page 9 Set time and wait for next minute impulse The clock operates as a slave clock TC Check the strapping according to the drawing for strapping page 5 Connect the TC wire according to the schema page 4 Set the clock for synchronisation function DCF See programming page 9 When a correct t...

Page 9: ... of 15 WESTERSTRAND URFABRIK AB P O Box 133 Tel 46 506 48000 Internet http www westerstrand se SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Connection temperature sensor this is an option Temperature sensor connection 1 red 2 black 5 Screen 1 2 3 4 5 ...

Page 10: ...ramming The programming is made by push buttons see below R Return Enter the base mode display time F Function Next function Accept displayed value P Program Enter the displayed function Increase displayed value programming time Push F until display shows Push P display shows year Push P until desired year 00 99 Accept with F Display shows month Push P until desired month 1 12 Accept with F Displa...

Page 11: ... SE 545 23 TÖREBODA Fax 46 506 48051 E mail info westerstrand se Push P until desired date 1 31 Accept with F Display shows hour Push P until desired hour 0 23 Accept with F Display shows minutes Push P until desired minute 00 59 Push F for synchronisation and the clock starts Display shows Push R The Programming is finished Display shows hh 12 nn 07 ti ne 12 07 ...

Page 12: ...ight intensity Push F until display shows Push P Display shows Light intensity 1 weakest 8 strongest Push P for desired light intensity Accept with F Display shows Push R for entering base mode or push F for next function Setting synchronisation Synchronisation for this model are minute impulse TC DCF or stand alone Push F until display shows Push P until desired synchronisation No synchronisation...

Page 13: ...seconds Push P for desired alternating time 0 25 Accept with F Display shows Alternating time for display temperature is 0 seconds Push P for desired alternating temperature 0 25 Accept with F Push R for entering base mode or push F for next function Setting Correction value for the temperature sensors With this function the temperature sensors can be adjusted 9 C Push F until display shows Push P...

Page 14: ...til display shows Push P Display shows FL Flemish Fr frensch de german FI Finish S Swedish n Norwegian d Danish En English Push P for desired language Push R for entering base mode or push F for next function Setting nation function for the dls rules With this function the nation can be choosed Push F until display shows Push P Display shows b Belgien Fr France de Germany FI Finland S Sweden n Nor...

Page 15: ... for desired format Push R for entering base mode or push F for next function Technical specification Mains 100 240V AC Connection Current 0 35A Temperature range 0 40 C Size of digits HH MM 50 mm red green yellow SMD LED s Size of digits SS 37 mm red green yellow SMD LED s Synchronisation Polarised 24V impulse 1 1 TC DCF Accuracy 0 1 sec 24 hour Dimension for LUMEX 5 Datex 425x175x50 mm Running r...