background image

 

WESTERSTRAND URFABRIK AB Sweden 

P.O. Box 133, SE-545 23 TÖREBODA 

Tel. +46 506-48000  Fax +46 506-48051 

E-mail: [email protected] 

Internet: www.westerstrand.se 

 

 

                            Instructions 
 
                              AUREA II 

Art. no. 119405-00, 119405-01, 119415-00, 119415-01

 

 

 
 

                      

 

 
 
 
 
 
 
 
 

Summary of Contents for 119405-00

Page 1: ...D URFABRIK AB Sweden P O Box 133 SE 545 23 T REBODA Tel 46 506 48000 Fax 46 506 48051 E mail info westerstrand se Internet www westerstrand se Instructions AUREA II Art no 119405 00 119405 01 119415 0...

Page 2: ...any kind expressed or implied including but not limited to its particular purpose Westerstrand Urfabrik AB reserves the right to make improvements and or changes to this manual or to the products and...

Page 3: ...personnel Except as explained elsewhere in the operating manual do not attempt to service this product yourself Removing covers may expose you to dangerous voltage points or other risks Refer all ser...

Page 4: ......

Page 5: ...E 545 23 T REBODA Fax 46 506 48 051 E mail info westerstrand se GENERAL 2 Options 2 INSTALLATION 3 SETTINGS OF DIP SWITCHES 5 6 MOUNTING 6 MANUAL PROGRAMMING 7 Time 7 Date 8 Spec 8 DCF Radio synchroni...

Page 6: ...that surrounds the clock decreases below a certain level This function can be turned off if wanted Important The clock has a lithium backup battery used as backup power when the main power is off Thi...

Page 7: ...nce of 160 mm are used for mounting the back plate to a wall The back plate can also be mounted to a wall by the two holes B Fig Back plate with 60 mm distance and can be fitted directly to a coupling...

Page 8: ...nd 1 1 minute impulse sync or slave Signal source Sync terminal Fig back plate IMP 4 IMP 3 In this configuration the 3 wire jumper Fig Clock backside must be left open not connected Radio signal 2 wir...

Page 9: ...Off On Off Radio synchronisation DCF MSF RDS IRIG B LON LTC Off Off On Impulse clock 1 2 minute sync Off On On Impulse clock 1 1 minute sync On Off On Impulse clock 1 2 minute slave On On On Impulse c...

Page 10: ...d se Fig Clock backside Mounting After all connections has been made and the back plate has been mounted to a wall mount the clock to the back plate according to First unlock the locking screw Fig Bac...

Page 11: ...ase mode Press R 2 Select function by pressing the F button until desired function is displayed One of the following texts Time TinE Programming of time Date dAtE Programming of date Spec SPEC Program...

Page 12: ...display shows Press P until desired year is displayed Accept with F The display shows Press P until desired month is displayed Accept with F The display shows Press P until desired day is displayed A...

Page 13: ...d dcf message has been received this month the display shows which is the day number when the last allowed dcf was received Press F The display shows which is the hour when the last allowed dcf was re...

Page 14: ...10 VA Size of digits 58 mm 58 45 mm Diode colour green red green red Diode light intensity 300mcd 300 mcd 300mcd 300 mcd Power consumption impulse 5 mA at 24V Synchronisation Polarised 24V impulse 1 1...

Page 15: ...Sidan har avsiktligt l mnats tom This page intentionally left blank...

Page 16: ...Sidan har avsiktligt l mnats tom This page intentionally left blank...

Page 17: ...Sidan har avsiktligt l mnats tom This page intentionally left blank...

Page 18: ......

Page 19: ......

Page 20: ......

Reviews: