background image

Surge Protection

This product features built-in surge protection circuitry in compliance with 

applicable standards.

For comprehensive protection of a luminaire installation against lightning and  

electrical surges, it is essential to cover mains supply and data input lines at  

the distribution board level, by using respective primary (Type 1) and secondary  

(Type 2) surge arrestors in compliance with EN61643-11/IEC61643-1.

Warning

Ensure that all required surge protection measures are in place and activated  

prior to luminaire installation. Also, disconnect luminaires before operating 

high-power devices such as, for example, electrical arc welders.

Installation tools

Mounting hardware used on this product 

includes fasteners with hexalobular socket 

heads (ISO 10664). Installation requires the 

use of matching tools.

WE-EF LEUCHTEN

 

Installation and Maintenance

Instructions 

Projector 

FLC210 LED 

FLC220 LED

FLC230 LED

FLC240 LED

FLC260 LED

FLC210-CC LED 

FLC220-CC LED

FLC230-CC LED

FLC240-CC LED

FLC260-CC LED 

FLC210-TW LED

FLC220-TW LED

FLC230-TW LED

FLC240-TW LED

FLC260-TW LED

Summary of Contents for FLC210-CC LED

Page 1: ...at all required surge protection measures are in place and activated prior to luminaire installation Also disconnect luminaires before operating high power devices such as for example electrical arc w...

Page 2: ...240 FLC240 EES Version FLC260 FLC260 EES Version FLC230 EES Version 196 FLC240 CC FLC240 TW 385 60 214 175 FLC260 CC FLC260 TW 18 14 44 FLC230 260 65 185 145 FLC230 CC FLC230 TW 138 61 190 18 14 44 FL...

Page 3: ...18 0 18 5 Windage area m for FLC220 0 030 for FLC230 0 054 for FLC240 0 090 for FLC260 0 116 Tools required Screwdriver T 25 T 30 provided by WE EF Screwdriver with blade 3 x 1 Accessories Wireless v...

Page 4: ...pply is switched on RU RSHUDWLRQ DV FRORXU FKDQJHU WKH RRGOLJKWV RI WKH VHULHV UHTXLUH D 0 FRQWURO VLJQDO DALI on request The operation without control signal may lead to error For operation with Tuna...

Page 5: ...temperature of 4000K in combination with light beam EE EES The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 2 8 m 3 4 m is not expected Notice...

Page 6: ...cessory or directly to a suitable surface Aim luminaire in the desired direction Warning Ensure not to damage any electric cable water pipe or other devices while drilling holes 3 Remove gear box cove...

Page 7: ...y cable through cable gland 6 Connect leads of mains supply cable D and second cable I for through wiring if required to respective terminals in terminal block F a ON OFF or wireless version L Phase N...

Page 8: ...through wiring daisy chain for the DMX signal is required remove resistor R between DMX in and DMX in of terminal K and connect outgoing DMX wires instead Do not remove resistor R if no through wiring...

Page 9: ...ion tighten screws G firmly max 100 Nm In addition tighten screw H max 6 Nm using a Torx T 30 tool provided by WE EF to secure orientation of luminaire not necessary for FLC220 Loosen Tighten Torque S...

Page 10: ...d Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 LQIR DVLDSDFL F ZH HI FRP WE EF LIGHTING Australia Tel 61 3 8587 0444 F...

Reviews: