SAFETY GUIDELINES

 This manual contains information that is very important 

to know and understand. This information is provided 

for SAFETY and to PREVENT EQUIPMENT PROBLEMS. 

To help recognize this information, observe all safety 

information labelled danger, warning, caution, and notice. 

DESCRIPTIONS

SUMP PUMPS 

Sump pumps are automatic pumps used to remove ground 
water from sump pits. The most common application is for 
basement drainage to prevent fl ooding in residential buildings. 
These sumps are designed to pump clear water only. 

EFFLUENT PUMPS

Effl uent pumps are pumps used to remove gray water from 
septic tanks, sump pits or laundry tray systems. Gray water 
is waste water from baths, sinks, washing machines, and 
other kitchen appliances. The pumps are designed to pass 
solids up to 3/4 in.

SEWAGE PUMPS 

Sewage pumps are pumps used to remove waste water 
that contains solids up to 2 inches in diameter. The most 
common application is for draining bathroom waste water to 
a sewer or septic line. 

UNPACKING

 Inspect your pump. Occasionally, products are damaged during 
shipment. If the unit is damaged, return the unit to the place of 
purchase for replacement. 

READ & FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS — DO NOT DISCARD 

200000-015    6/10

© 2010

Sump, Effl uent and Sewage pumps

INSTALLATION MANUAL

IMPORTANT SAFETY INFORMATION

WARNING INDICATES A POTENTIALLY HAZARDOUS 
SITUATION WHICH, IF NOT AVOIDED, COULD RESULT 
IN DEATH OR SERIOUS INJURY.

RISK OF ELECTRIC SHOCK. TO REDUCE THIS 

RISK, OBSERVE THE FOLLOWING WARNINGS: 

MAKE SURE THERE IS A PROPERLY GROUNDED 
RECEPTACLE AVAILABLE. 

 This pump is supplied with a 

grounding conductor and grounding-type attachment plug. To 
reduce the risk of electric shock, be certain that it is connected 
only to a properly grounded, grounding-type receptacle.

NEVER REMOVE THE GROUND PRONG 

from the plug or 

bypass the grounding wires.

FOR ADDED SAFETY 

the receptacle should be protected with a 

ground fault circuit interrupter (GFCI).  All wiring must be performed 
by a qualifi ed licensed electrician and comply with the National 
Electric Code and all applicable local codes and ordinances.

DO NOT REMOVE POWER SUPPLY CORD 

and strain relief or 

connect conduit directly to the pump.

MAKE SURE THE POWER SUPPLY HAS A FUSE OR 
CIRCUIT BREAKER 

rated to handle the current (amps) noted 

on the nameplate of the pump.

DO NOT USE AN EXTENSION CORD.  

Extension cords could 

present a safety hazard if not sized properly, become damaged 
or the connection falls into the sump.  If receptacle is not within 
reach of the pump’s power cord, contact a qualifi ed  licensed 
electrician to install a new receptacle.

ALWAYS DISCONNECT THE PUMP 

from power supply before 

installing, servicing or making any adjustments.

DO NOT SUBMERGE PEDESTAL MOTOR 

or allow motor to 

be exposed to water. 

DO NOT WALK 

on the fl oor when water is present until all 

power is turned off.  If the electric panel is in the basement, call 
an electrician.

NEVER HANDLE A PUMP 

or motor with wet hands or when 

standing on a wet or damp fl oor while the pump is plugged into 
the power supply.

WASH HANDS AFTER HANDLING.  

According to the state of 

California (Prop 65), this product may contain chemicals known to 
the state of California to cause cancer and birth defects or other 
reproductive harm.

 

RISK OF ELECTRIC SHOCK.  

This pump has not been 

investigated for use in swimming pool and marine areas.

DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS 

such as gasoline, fuel oil, kerosene, etc. Do not use in a fl ammable 
and/or explosive atmosphere. Pump should only be used to pump 
clear water. Personal injury and/or property damage could result.

Read and save these instructions. This manual contains very important Safety Warnings and Operating Instructions. You will need to refer to 
it before attempting any installation or maintenance. Always keep this manual with the unit so that it will be easily accessible. Failure to read 
and follow these warnings and instructions could result in property damage, serious injury or death.

Printed on 100% Recycled Paper

Summary of Contents for 200000-015

Page 1: ...ected with a ground fault circuit interrupter GFCI All wiring must be performed by a qualified licensed electrician and comply with the National Electric Code and all applicable local codes and ordina...

Page 2: ...debris that could interfere with the operation of the switch IT IS RECOMMENDED TO USE A CHECK VALVE with this pump to prevent the back flow of fluid after each pump cycle DO NOT INSTALL OR OPERATE TH...

Page 3: ...undation so any remaining water will drain away and not freeze 3 TYPICAL SUMP INSTALLATION 1 This installation must be in accordance with the National Electric Code and all applicable local codes and...

Page 4: ...discharge Water stream will be visible from the hole when the pump is running The hole must be cleaned periodically 9 Install a union to allow easy removal of the pump for cleaning and service 10 Ins...

Page 5: ...ng instruction supplied with device or float 9 Install a sealed basin cover to prevent debris from falling into the basin personal injury and contain gases and odors 10 A union should be installed abo...

Page 6: ...protector and may restart unexpectedly Protector tripping is an indication of motor overloading as a result of operating the pump at low heads excessively high or low voltage inadequate wiring incorre...

Page 7: ...g available at local hardware stores to isolate pump vibration from discharge plumbing Pump will not shut off 1 Switch 2 Switch obstructions 3 Restricted discharge obstruction in piping 4 Excessive in...

Page 8: ...8 NOTES INSTALLATION MANUAL Printed on 100 Recycled Paper...

Page 9: ...S CURIT la prise de courant doit tre prot g e avec un disjoncteur de fuite la terre DDFT Tout le c blage doit tre effectu par un lectricien qualifi et se conformer au code national de l lectricit des...

Page 10: ...UTILISER UN CLAPET DE NON RETOUR avec cette pompe pour pr venir le retour d eau de liquide apr s chaque cycle de pompe NE PAS INSTALLER NI FAIRE FONCTIONNER LA POMPE SI ELLE A T ENDOMMAG E DE TOUTE F...

Page 11: ...plac sur une pente vers le bas loin de la fondation pour que l eau restante se draine au lieu de geler 11 INSTALLATION TYPIQUE DE PUISARD 1 Cette installation doit tre conforme au Code national d lect...

Page 12: ...ent 9 Installer un raccord union pour permettre d enlever facilement la pompe pour le nettoyage et l entretien 10 Installer un clapet de non retour requis pour viter tout retour d eau Il doit tre inst...

Page 13: ...cuvette scell e pour emp cher les d bris d y tomber pr venir les blessures et contenir le gaz et les odeurs 10 Un raccord union doit tre install au dessus de la cuvette pour permettre d enlever facil...

Page 14: ...pourrait red marrer de mani re impr vue Le d clenchement du protecteur est une indication de surcharge du moteur suite l op ration de la pompe faible hauteur de chute tension excessivement haute ou ba...

Page 15: ...pas 1 Interrupteur d fectueux 2 Obstruction d interrupteur 3 D charge obstru e obstruction dans la tuyauterie 4 Entr e excessive ou pompe non pas de la taille appropri e pour l application 1 Remplacer...

Page 16: ...16 NOTES MANUEL D INSTALLATION Printed on 100 Recycled Paper...

Page 17: ...URIDAD el tomacorriente debe ser protegido con un interruptor de descarga a tierra GFCI Todo el alambrado debe ser realizado por un electricista autorizado y calificado y debe cumplir con los C digos...

Page 18: ...A EL USO DE UNA V LVULA DE RETENCI N con esta bomba para prevenir el reflujo de l quido despu s de cada ciclo de la bomba NO INSTALE NI HAGA FUNCIONAR LA BOMBA SI HA SIDO DA ADA DE CUALQUIER MANERA NO...

Page 19: ...ientos para que toda agua restante escurra y no se congele 19 INSTALACI N T PICA DE SUMIDERO 1 Esta instalaci n debe realizarse de acuerdo con los C digos el ctricos nacionales y todos los c digos y o...

Page 20: ...jero El agujero debe limpiarse peri dicamente 9 Instale una uni n para facilitar el retiro de la bomba para limpieza y servicio 10 Instale una v lvula de retenci n requerida para prevenir el reflujo D...

Page 21: ...n el dispositivo o flotador 9 Instalan una tapa de pileta con sello para impedir la ca da de residuos en la pileta lesiones personales y para contener gases y olores 10 Debe instalarse una uni n arrib...

Page 22: ...ndica una sobrecarga del motor debido a que la bomba est funcionando con cargas bajas baja restricci n de descarga voltajes excesivamente altos o bajos un cableado inadecuado condiciones incorrectas d...

Page 23: ...l espiral limpie y o reemplace el impulsor La bomba no se apaga 1 Interruptor defectuoso 2 Obstrucci n del interruptor 3 Descarga restringida obstrucci n en la tuber a 4 Demasiado flujo de entrada o l...

Page 24: ...24 NOTAS MANUAL DE INSTALACI N Printed on 100 Recycled Paper...

Reviews: