SSL 4000 E-Channel                SSL 4000 G-Channel 

                    

                         

 

 

Summary of Contents for SSL 4000 E

Page 1: ...SSL E Channel G Channel User Manual 1 SSL 4000 Collection SSL 4000 E Channel SSL 4000 G Channel...

Page 2: ...9 Expander Gate 9 Dyn To 9 E CHANNEL EQ SECTION CONTROLS 10 Low and High Pass Filters 10 High Frequency EQ Section 10 High Medium Frequency EQ Section 10 Low Medium Frequency EQ Section 10 Low Freque...

Page 3: ...ernal sub mix allowed sound engineers to discover unique history making applications of this console technology Whether used to record instruments such as piano and drums or for final mixing these inn...

Page 4: ...of one sample Dynamics Section The dynamics section consists of a soft knee compressor limiter and an expander gate Dynamics can be switched to pre equalizer default or post equalizer CH OUT Although...

Page 5: ...r when Split is selected the low pass and high pass filters are placed before the dynamics processors in the chain The equalizer can be switched into the dynamics sidechain to afford simple de essing...

Page 6: ...SSL E Channel G Channel User Manual 6 SSL Channel Routing Diagram...

Page 7: ...SSL E Channel G Channel User Manual 7...

Page 8: ...SSL E Channel G Channel User Manual 8 3 Controls and Interface...

Page 9: ...The expander s Threshold is variable from 30 dB to 10 dB Range is variable from 0 40 dB When the Attack time switch is set to Slow F ATK off attack time is auto sensing and program dependent Fast set...

Page 10: ...obs Range 1 5 kHz 16 kHz Gain range is 18 dB for bell shape 16 5 dB for shelving Selecting Bell changes the HF EQ from shelf to bell shape High Medium Frequency EQ Section green knobs Range 600 Hz 7 k...

Page 11: ...Section Magenta knobs Range 1 5 kHz 16 kHz Gain range is 17 dB shelving High Medium Frequency EQ Section green knobs Range 600 Hz 7 kHz Q is continuously adjustable from 0 1 to 3 5 Gain varies from 2...

Page 12: ...switches the filters into the dynamics sidechain Master Section Level Indicator expresses levels in dBFS although all parameters are expressed as dBu Input and Output switches above the meter allow y...

Page 13: ...Setup A B toggles between two sets of parameters within the same processor useful when comparing different parameter settings in order to achieve optimal results Copy A B copies the current settings...