background image

Programmable Thermostat WA-XSTAT

I N S T R U C T I O N S

English

The electronic comfort controller is a clock
thermostat that can be programmed to function
as a floor temperature controller and room
temperature controller with a limitation function.
The thermostat is intended for mounting in a 
55 mm standard wall socket. The operating area
ranges from +0° to +30°C. The thermostat
incorporates a clock enabling the programming
of several setback functions.

Controller setting WA-XSTAT

Program choice:

Floor temperature control
Floor temperature control with 2 sensors
Air temperature control
Air temperature control with floor 
temperature limit
Regulator control
External control

The controller is designed in accordance
with current product standard EN 60730-
2-9, and fulfill hereby the requirements to both
LVD and EMC directives.

The controller must not be put into operation
until it has been ascertained that the entire
installation complies with current general safety
requirements for electrical installations. 

The warranty is only valid if the controller has
been put into operation in accordance with the
operating instructions supplied with the
controller and these installation instructions. 

Technical data
Supply voltage  . . . . . . . . . . .230V ±15%, 50 Hz
Output relay SPST . . . . . . . . . . . . . .16A, 3600W
Temperature range  . . . . . . . . . . . . . . . .+0/+30˚C
Temperature limitation   . . . .min./max. +5/+55˚C
Clock function  . . . .1 pre-installed programmes

28 optional setback programmes

Ambient temperature  . . . . . . . . . . . . . . .0/+30˚C
On/off differential  . . . . . . . . . . . . . . . . . . . .0,4˚C
Housing  . . . . . . . . . . . . . . . . . . . . . . . . . . .IP 21
Sensor type  . . . . . . . . . . . . . . . . . . . . . . . . .NTC
- heating is switched off in case of sensor failure
Dimensions (HxWxD) (fig. 6)  . . . . .86/86/48 mm
The controller is maintenance-free.

Control pollution degree: 2
Pollution degree 2 is representative of normal
household air circulation.

Overvoltage category: III

Classification
The product is a class II device (reinforced
insulation) and the product must be connected
to the following conductors:
1) Phase (L)
2) Neutral (N)

The thermostat is constructed to store the clock
up to 4 hours at an occasional voltage
interruption. It is not suitable for use by regular
voltage interruptions. (Example: Power term
applications). At such conditions a constant
power supply for the thermostat must be
ensured.

WARNING – Important Safety Instructions
Isolate supply before carrying out any
installation or maintenance work on this control
unit and associated components. This control
unit and associated components should only be
installed by a competent person (i, e qualified
electrician). Electrical installation to be in
accordance with latest IEE Wiring Regulations
and appropriate Statutory Regulations. 

Mounting of sensor
Floor sensor: Placed in an approved non
conductive installation pipe in accordance with
EN 61386-1, which is embedded in the floor.
(fig. 3). The pipe is closed in the end and placed
as high as possible in the concrete layer. The
installation pipe must be centered in between
the heating cable.

The enclosed 3 meter sensor cable can be
extended up to 100 m by means of a separate
cable. If the extension cable is lighter than
H05VV-F, it shall equally be installed in an
unbroken installation pipe between the sensor
cable and the extension cable. Two remaining
cores of a multi-core cable which, for example,
supplies current to the heating wires of a floor
heating system, must not be used. The
switching peaks of such current supply lines
may create interfering signals that prevent
optimum controller function. The two-corecable
must be placed in a separate pipe.

Controller installation site
The controller must be mounted on the wall so
that air can circulate freely around it (fig. 4). An
installation site must be selected where the
controller is not exposed to foreign energy
sources, e.g. solar radiation. The controller must
not be exposed to draughts coming from, for
example, windows, doors or cold outer walls. 

The controller has a built-in fault interrupter
circuit which interrupts the heating in case of
disconnected or short-circuited sensor.

Mounting of controller 
The  single gang mounting box must have a
debt of no less than 25 mm.
1. Use a screwdriver in both sides to open the

lock.
The cover must be dismounted (fig. 1).

2. Connect cables according to the diagram

(fig. 2a-2b).

All electrical connections must be performed by
a fully qualified and Part P certified electrician.

3. The thermostat is mounted in the wall 

socket. The cover is remounted.

Programming
(See user manual)
The controllers are delivered with a pre-installed
setback programme.

If the pre-installed setback programme is not
used, there are different programmes which can
be selected and used on the required days.

The controllers calculate when the heating is to
be switched on to make sure that the comfort
temperature is obtained to the required time.

Fault location
If the sensor is disconnected or short-
circuited, the heating system is switched off.
The sensor can be checked according to the 
resistance table fig. 5.

Environment and recycling
Please help us to protect the environment by
disposing of the packaging in accordance with
the national regulations for waste processing. 

Recycling of obsolete appliances

Appliances with this label must not
be disposed off with the general
waste. They must be collected
separately and disposed off
according to local regulations.

Warmup Plc
702 Tudor Estate · Abbey Road
London NW10 7UW
T. +44 845 345 2288
F. +44 845 345 2299
warmup.com

Español

El controlador electrónico de confort es un
termostato cronometrado que se puede
programar para funcionar como controlador de
temperatura del piso y como controlador de
temperatura ambiente con una función
limitadora.
El termostato está diseñado para montaje en un
receptáculo de pared estándar de 55 mm. Los
límites de funcionamiento son de 0° a +30 °C.
El termostato incorpora un reloj que permite la
programación de varias funciones de reducción
de temperatura.

Ajuste de controlador WA-XSTAT

Opción de programa:

Control de temperatura de piso
Control de temperatura de piso con 2 
sensores
Control de temperatura del aire
Control de temperatura del aire con límites 
de temperatura de piso
Control regulador
Control externo

El controlador está diseñado de acuerdo
con las normativas de producto vigentes
EN 60730-2-9, y por lo tanto cumple los
requisitos de las directivas LVD y EMC.
No se debe accionar el controlador antes de
verificar que toda la instalación cumpla con los
requisitos vigentes de seguridad general para
instalaciones eléctricas.

La garantía es válida solamente si el controlador
se ha puesto en servicio de acuerdo con las
instrucciones de operación suministradas con
el controlador y estas instrucciones de
instalación.

Datos técnicos
Tensión de alimentación   . . .230 V ±15%, 50 Hz
Relé de salida SPST  . . . . . . . . . . .16 A, 3600 W
Rango de temperatura  . . . . . . . . . . . .+0/+30 °C
Limitación de temperatura mín./máx. +5/+55 °C

Type WA-XSTAT

57627B 11/06 (BJ)

NW107UW-A

Reviews: