background image

ENGLISH

w w w . p r o l i g h t . c o . u k

USER MANUAL

D

P

 3

0

6

 D

IG

IT

A

L

 S

P

E

A

K

E

R

 P

R

O

C

E

S

S

O

R

S

P

R

O

F

E

S

S

I

O

N

A

L

 

D

I

G

I

T

A

L

 

P

R

O

C

E

S

S

O

R

Order code: PROC02

Summary of Contents for DP 306

Page 1: ...ENGLISH w w w p r o l i g h t c o u k USER MANUAL DP 306 DIGITAL SPEAKER PROCESSORS P R O F E S S I O N A L D I G I T A L P R O C E S S O R Order code PROC02 ...

Page 2: ...UTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning not...

Page 3: ...the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperatur...

Page 4: ...Easy parameter copying Signal test with selectable pink or white noise with 20kHz 20kHz adjustable sine wave and signal range 2 x 20 character LCD display screen with push buttons for easy and quick selection 32 user presets every preset can be saved and adjusted separately with code protection Can be controlled with PC via a USB and RS 232 connector Front Panel 1 Input level indicators 5 precisio...

Page 5: ...enter an ID for the first time press the UTIL button and choose from 1 254 If there is more than 16 units to be linked or if there is a long distance between each link a parallel connection is needed with a 120Ω resister on the end of the RS 485 cable 2 Now press the UTIL button to enter a protection code the code can either be a word or a set of numbers Please note that the protection code is pre...

Page 6: ...the high low pass filter BUTTERWORTH BESSEL and LINKWITZ the slanting rate is DP24 36 is 6dB 48dB DP48 is 6dB 24dB 6 Press the PHASE button to edit the phase settings The phase settings range from 0 180 1 The tolerant preferred is GAIN this ranges from 60dB 12dB 2 Now press the PEQ button to edit the parameter settings The Current filter location DP24 36 is 1 8 DP48 is 1 6 The scale of F is 20Hz 2...

Page 7: ...rocess 2 Once the driver has been installed double click on the PC software on the CD and click NEXT STEP to continue This will now carry on until the instruction finishing setup appears When it has finished installing the software you can then exit 3 Now connect the unit to the PC using the supplied USB cable After turning on the unit your PC will automatically update the hardware During setting ...

Page 8: ...ANAGER in the HARDWARE section as shown in the image below 5 When the device manager window is open check the COM number in the USB SERIAL PORT should be below COM COM and LPT as shown in the image below If you find that the COM is above COM8 please amend it below 8 on the menu COM set up ...

Page 9: ...k on the COM SETUP in the TOOLS drop down window as shown in the image below 7 A new small window should now appear on your screen as shown below Make sure that the COM number is the same as you have previously done at step 5 of this guide and click OK ...

Page 10: ...device and click OK Note All of the device s ID s are 1 9 The software will now do an auto search for the connected device When prompted click OK 10 It will now show a RED status bar at the bottom of the window when the software has connected successfully To exit the software you need to click on the ONLINE tab first before you disconnect the USB cable or shut down the device ...

Page 11: ...e menu for different operations 2 Function Panel Area Selects the menu for different operations 3 Parameter Adjustment Area General parameter setting for the selected function 4 Preset Operation Area Save transfer or change the preset name ...

Page 12: ...et document prs Uploads the users preset data of the current connected device and saves to the computer unt Downloads the users preset data saved in the current device and deletes all of the users preset data unt Resumes the initial setting of the connected device and deletes all of the users preset data Exits the software Shows the online status Shows the tool bar Shows the input and output level...

Page 13: ...THD Cross talk 20Hz 20kHz 0 5dB 115dBu 0 01 at 1 kHz 10dBv 100d Below full scale Type Max input level Impedance Balanced XLR 20dBu 1MΩ stereo 500kΩ mono Type Max output level Cross talk Balanced XLR 20dBu 500Ω 24 bit sigma delta converters 48kHz sampling rates 2 x 20 character LCD display for parameter settings and function selections AC 90 255V Fuse 250V AC 2A Fast 480 x 205 x 45mm 2 88Kgs ...

Page 14: ...l the unit from a long distance Several units can be linked for long distance control via the RS 485 The RS 485 can control the operation of several units at long distance via the central control system Achievable long distance control functions by RS 485 1 Input channel gain 2 Input channel mute on off 3 Output channel gain 4 Output channel mute on off 5 Transfer appointed scene ...

Page 15: ......

Page 16: ......

Reviews: