Page 1: ...V290iA User Guide Version 1 0 ...

Page 2: ...anty unless specifically incorporated by reference into such contract or warranty The information herein is merely descriptive in nature and does not constitute a binding offer for the sale of the product described herein Any use of the Vyyo Inc logo or trademarks is forbidden without prior written approval from Vyyo Inc All trademarks mentioned herein are the property of their respective owners V...

Page 3: ...he following measures Reorient or relocate the antenna Increase the distance between the equipment and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver was connected Consult the dealer or an experienced radio TV technician for assistance NOTE This equipment is authorized under FCC ID No LDK102052P and complies with 15C User installation is pr...

Page 4: ......

Page 5: ...k 3 List of Abbreviations 4 Chapter 1 Overview 7 V290iA and the Vyyo BWA System 7 Chapter 2 Physical and Functional Description 9 V290iA Basic Description 9 Interfaces 10 Housing 11 Heating and Cooling 11 Power 12 Modem V290iA Initialization Process 12 Chapter 3 Installing the V290iA 15 Prerequisites to Installation 15 Verifying Package Contents 16 Mounting the V290iA 16 Wall Mounting 17 Pole Moun...

Page 6: ...ations 35 V290iA General Characteristics 35 UHF Radio Characteristics 36 Appendix B Antennas Technical Specifications 37 Shrouded Yagi Antenna 37 Yagi Electrical and Mechanical Specifications 37 Mounting Options 38 Flat Panel Subscriber Antenna 39 Flat Panel Electrical and Mechanical Specifications 39 Flat Panel Environmental Specifications 40 Appendix C Power Cable Specifications 41 Power Connect...

Page 7: ...ndix F Ethernet Cable Specifications 49 Ethernet AUI Port Pinout DB 15 49 Ethernet Version 2 and IEEE 802 3 Physical Characteristics 50 Ethernet Coaxial type Connection Limits for 10 Mbps Transmission 50 Appendix G FCC Declaration of Conformity 51 ...

Page 8: ......

Page 9: ...el required to install configure or maintain the V290iA Document Objectives This guide is designed to be used as a tool in the initial installation and periodic maintenance of the V290iA It contains information on how to perform the following tasks Installing the V290iA Configuring the V290iA Maintaining the V290iA Troubleshooting the V290iA Document Conventions The following icons appear througho...

Page 10: ... operation Chapter 4 Configuring the V290iA This chapter explains how to configure the V290iA components Chapter 5 Maintaining the V290iA This chapter details the normal operation of the V290iA LEDs and describes how to upgrade the V290iA software Chapter 6 Troubleshooting This chapter provides troubleshooting information to help solve common problems Appendix A V290iA Technical Specifications Thi...

Page 11: ...of Conformity Related Documentation For information on other Vyyo wireless system topics see the following guides NMS User Guide Base Station User Guide V290iA Quick Reference Guide Obtaining Documentation To obtain additional documentation please contact info vyyo com Documentation Feedback We welcome your comments about this guide Please send comments to Address 6625 The Corners Parkway Suite 21...

Page 12: ...Dynamic Host Configuration Protocol DOCSIS Data Over Cable Service Interface Specifications DS Downstream DSCP Differentiated Services Code Point FDD Frequency Division Duplexing FEC Forward Error Correction FTP File Transfer Protocol GHz Gigahertz ICMP Internet Control Message Protocol IEEE Institute of Electrical and Electronic Engineers IETF Internet Engineering Task Force IGMP Internet Group M...

Page 13: ...rts Group Ms Millisecond MTU Maximum Transmission Unit NLOS Non Line of Sight NMS Network Management System Ns Nanosecond PHY Physical Layer PPP Point to Point Protocol QAM Quadrature Amplitude Modulation QoS Quality of Service QPSK Quadrature Phase Shift Keying RF Radio Frequency RFC Request For Comments SNAP Subnetwork Access Protocol SNMP Simple Network Management Protocol SNR Signal to Noise R...

Page 14: ......

Page 15: ...y to IP devices located at the CPE site Serial ports provide connectivity to SCADA devices A manageable Power and Control Card The V290iA connects to an external antenna Two optional antennas are available Refer to Appendix B Antennas Technical Specifications for the antennas technical specifications V290iA and the Vyyo BWA System The V290iA is the CPE component of the Vyyo Broadband Wireless Acce...

Page 16: ......

Page 17: ...uting engine includes the host processor and memory It is connected to the V284 A through a Fast Ethernet interface 4 Port Fast Ethernet Switch Mobile Interface Card FESMIC The 4 port FESMIC provides four sets of Fast Ethernet signals One of these is connected to the WMIC 4 Port Serial Mobile Interface Card SMIC The 4 port SMIC provides four sets of serial signals Wireless Mobile Interface Card WM...

Page 18: ...5 Ethernet ports The Ethernet ports are available to connect IP devices such as remote cameras and security devices Refer to Appendix 0 Ethernet Cable Specifications for cable specifications UHF RF antenna connector Use for connecting to the Vyyo wireless network Refer to Appendix D UHF Antenna Cable Specifications for cable specifications Two WiFi antenna connectors the Cisco router has wireless ...

Page 19: ...g screws to maintain a proper seal The Ethernet and Serial interfaces use a rugged design to protect the interface pins The interface panel is located on the bottom of the V290iA when it is mounted in the standard way and the RF antenna connection is on the top A 100 cable is attached to both halves of the housing to permit ease of service for a field technician A console port for the Cisco router...

Page 20: ...tream channels in the sector The upstream information includes symbol rate modulation FEC preamble and scrambling 4 Receives bandwidth allocation MAP The WMTS periodically transmits on the downstream channel a broadcast message to all modems on the sector regarding the upstream bandwidth access opportunities of a coming time interval 5 Performs ranging and adjustments The modem synchronizes with t...

Page 21: ...k and more from the DHCP server Note The description of how the Cisco router establishes IP connectivity applies to the V290iA default Cisco setting The customer may change the Cisco setting to a fixed IP address or any other IP addressing method supported by the Cisco IOS The Cisco addressing is not managed by the Vyyo NMS and should be configured by the system administrator ...

Page 22: ......

Page 23: ...stallation Before installing the V290iA 1 Make sure the antenna is installed and adjusted 2 It is recommended to have a PC available for connecting to one of the Console ports 3 Provision the V290iA in the NMS refer to the NMS User Guide You need the V290iA s MAC address which is displayed on the V290iA label as shown in Figure 5 Figure 5 V290iA MAC Address 4 Check the installation environment to ...

Page 24: ... have the necessary tools Verifying Package Contents Make sure the package contains the following One pole mounting bracket One main mounting bracket Four HEX HD SST 1 4 20 NC x 5 8 screws Four SST FLAT RU 1 4 washers Four HEX HD SST 3 8 16 UNC x 3 5 FULL THREAD screws Four SST LOCK 1 4 washers Four SST LOCK 3 8 washers Mounting the V290iA The V290iA can be mounted on a wall a pole or a shelf In w...

Page 25: ...terface Panel LEDs on page 29 Pole Mounting To mount the V290iA on a pole 1 Orient the device so the main mounting bracket refer to Figure 3 faces the wall and the interface panel faces down 2 Place the provided pole mounting bracket around the pole at the desired height 3 Attach the pole mounting bracket to the main mounting bracket of the device using the enclosed self locking press nuts 4 Verif...

Page 26: ...ttach the power cable to the power outlet on the interface panel The device powers up 7 Monitor the Modem RF LED on the interface panel to verify that the modem is functional For more information on the Modem RF LED refer to Interface Panel LEDs on page 29 Cable Connections The following figure displays the V290iA front panel connectors Figure 6 V290iA Front Panel Connectors Perform the following ...

Page 27: ...ower switch exists turn it OFF c Connect the Power cable Initial Operation The V290iA starts operating as soon as power is connected If you turned off the external power switch prior to connecting the power cable turn it ON The front panel LEDs behave as described in Interface Panel LEDs on page 29 If the behavior of the LEDs deviates from standard refer to Troubleshooting on page 33 ...

Page 28: ......

Page 29: ...es default IP address and Netmask information for the V284 modem and the Cisco router The default IP information is as follows Table 1 Default IP Settings Parameter Value Modem IP Address 192 168 100 1 Modem Netmask 255 255 255 0 Router Ethernet IP Address 192 168 100 10 Router Ethernet Netmask 255 255 255 240 Router VLAN Loopback IP 10 0 0 254 Router VLAN Loopback Netmask 255 255 255 0 The Modem ...

Page 30: ...IP address with the relevant TCP port The default configuration disables all the dynamic routing protocols and the Cisco discovery protocol Default Configuration Parameters MARC IP address via the RF UHF link is acquired by DHCP and is 192 168 100 10 when the UHF modem is not registered to the WMTS MARC IP address via the FESMIC LAN interface is 10 0 0 30 WMIC IP address is 10 0 0 1 Default Config...

Page 31: ...timeout 0 0 session limit 1 modem InOut no exec transport input telnet transport output telnet escape character NONE telnet break on ip stopbits 1 line aux 0 line vty 0 4 password vyyo login end Router SCADA Traffic Configuration The V290iA optionally interfaces with asynchronous SCADA devices via serial ports Ser0 Ser3 This section illustrates how to transmit SCADA traffic using TCP encapsulation...

Page 32: ... keepalives out service timestamps debug datetime msec service timestamps log datetime msec no service password encryption no service config hostname Router boot start marker boot end marker no aaa new model resource policy ip subnet zero ip cef no ip dhcp use vrf connected ip host SER1 4001 10 1 1 2 ip host SER2 4002 10 1 1 2 ip host SER3 4003 10 1 1 2 ip host SER4 4004 10 1 1 2 no ip ips deny ac...

Page 33: ... con 0 stopbits 1 flowcontrol NONE line 1 no motd banner no exec banner exec timeout 0 0 session timeout 0 0 no flush at activation no vacant message no modem inout autocommand telnet SER1 stream no activation character special character bits 8 escape character NONE autohangup stopbits 1 exec no autobaud speed 9600 flowcontrol NONE transport input NONE line 2 no motd banner no exec banner exec tim...

Page 34: ...ort input NONE line aux 0 line vty 0 4 end V290iA Called side Configuration The following displays the called side configuration Current configuration 1719 bytes version 12 4 service tcp keepalives in no banner incoming service timestamps debug datetime msec service timestamps log datetime msec no service password encryption no service config hostname Router boot start marker boot end marker no aa...

Page 35: ...ernet2 3 interface Vlan1 ip address 10 0 0 62 255 255 255 224 no shutdown ip classless ip route 0 0 0 0 0 0 0 0 FastEthernet0 0 no ip http server no ip http secure server no cdp run control plane line con 0 stopbits 1 line 1 4 no exec banner no vacant message modem DTR active special character bits 8 no autobaud speed 9600 no exec flowcontrol NONE transport input telnet escape character NONE dispa...

Page 36: ......

Page 37: ...lowing table describes the LEDs and their functions Table 2 V290iA LEDs LED Function Power Status Amber when power is supplied to both the V284 and the Cisco router Green when power is supplied only to the V284 Red when power is supplied only to the Cisco router Blinks green when a power fault is detected in the V284 Blinks red when a power fault is detected in the Cisco router Blinks amber when a...

Page 38: ...tream link is idle or there is a problem with data reception Flashing when the downstream link is being acquired When Status LED is On Flashing when data is transferring in either in the Upstream or Downstream direction Link Act for each Serial port Green when the serial port is operational Blinks red when packets are transmitted or received Link for each Ethernet port Green when the Ethernet port...

Page 39: ...ptop which is running a TFTF server pumpkin 2 Make sure the TFTP server pumpkin is activated and set to permit access to the directory in which the software package is located 3 Connect a serial cable from the serial port on the laptop to the Modem Console port on the interface panel 4 Open terminal emulation software on the laptop and verify the connection with the V290iA 5 Type cd d to go to the...

Page 40: ......

Page 41: ...V290iA User Guide 33 6 Troubleshooting TBD ...

Page 42: ......

Page 43: ...A General Characteristics Parameter Specification Physical Height 13 4 340 mm Width 12 2 310 mm Depth 7 1 180 mm Max Weight 26 5 lbs 12 Kg Environmental Operating temperature 22 F to 158 F 30 C to 60 C Storage temperature 40 F to 185 F 40 C to 85 C Relative humidity 95 non condensing Vibration IEEE 1613 Class V S 2 Shock IEEE 1613 100 mm Ingress Protection IP40 1 mm objects Regulations IEEE std 16...

Page 44: ...QAM QPSK SNR for BER 10E6 24 dB 19 dB 13 dB Minimum signal level 87 dBm Maximal signal level 49 dBm Frequency tolerance 50 KHz Adjacent channels for BER 10E6 10 dB FEC ITU T J 83 Reed Solomon Trellis Decoder Upstream Frequency 776 777 MHz Channel bandwidth 325 KHz Modulation 16QAM or QPSK Transmit level 17 to 27 dBm PA output power P1dB 32 dBm FEC Reed Solomon with optional training ...

Page 45: ...range 746 777 MHz Input Impedance 50 Ohms Return Loss 15 dB Front to Back Ratio 20 dB Maximum Input Power 250 Watts Polarization Vertical Horizontal Forward Gain 11 5dBd 3 dB Beamwidth E Plane 37º H Plane 41º Connection N socket Radiator ptfe Printed Circuit Elements Aluminium Alloy Radiator Feed Sucoform 141 Antenna Base Sandcast Aluminium Alloy Grade LM25 Radome Fire retardant Polyurethane Mould...

Page 46: ...cal Wind loading 45m s 285N with 1 2 radial ice 306N Survival Wind Speed 300km h with 1 2 radial ice Operational Temperature Range 50ºC to 80ºC Mounting Options Error Not a valid link Figure 9 Mounting for Vertical Polarization of the Yagi Antenna Error Not a valid link Figure 10 Mounting for Horizontal Polarization of the Yagi Antenna ...

Page 47: ...0682 Electrical Frequency range 746 777 MHz Gain 9 5 dBi min VSWR 2 1 max S dB beamwidth AZ 43º typ EL 55º typ Polarization Linear Vertical or Horizontal Cross polarization AZ 26 dB max EL 26 dB max F B ration 25 dB max Input impedance 50 ohm Input power 6 W max Lightning protection DC Grounded Mechanical Dimensions L x W x D 450 x 450 x 30 mm max Weight 3 Kg max Connector N type Female Radome Pla...

Page 48: ...cycling IEC 68 2 14 1 h 45ºC 70ºC 3 Cycles Vibration IEC 60721 3 4 30 min axis Random 4M5 Shock Mechanical IEC 60721 3 4 4M5 Humidity ESTI EN300 2 4 T4 1 E 144 h 95 Water Tightness IEC 529 IP63 Solar Radiation ASTAM G53 1000 h Flammability UL 94 Class HB Salt Spray IEC 68 2 11 Ka 500 h Ice and Snow 25 mm Radial Wind Speed Survival Operation 220 Km h 160 Km h Wind Load Survival Front Thrust Side Th...

Page 49: ...18awg manufactured by Tyco MFG 66101 3 Boot 11 Manufactured by Tyco MFG 207489 1 This connector is same as the one used for the Cisco 3230 External Cables Requirements Use cables suitable for the environmental required specification Do not exceed the allowed cable length according to the common STD Serial and Ethernet Use the pin out description refer to Internal Connectors Description below to pr...

Page 50: ...0i Name Connector Description Pin Number Pin2 TxD Pin3 RxD Pin5 GND 2 PSC console Connector D Type 9pins Female Pin1 4 6 7 8 9 NC Item V290i Name Connector Description Pin Number Pin1 9 NC Pin2 TxD out Pin3 RxD in Pin4 DSR in Pin5 GND Pin6 DTR out Pin7 CTS in 3 MARC console Connector D Type 9pins Female Pin8 RTS out Item V290i Name Connector Description Pin Number Pin1 RxPO Pin2 RxNO Pin3 TxPO Pin...

Page 51: ...m V290i Name Connector Description Pin Number 5 UHF antenna Connector N Type female 50 ohm Standard Item V290i Name Connector Description Pin Number Pin1 Negative Pin2 Positive Pin3 Negative 6 DC Input Circular plastic connector 4 pins male Pin4 Positive ...

Page 52: ......

Page 53: ...V290iA User Guide 45 D UHF Antenna Cable Specifications This appendix lists the technical specifications of the antenna cable TBD ...

Page 54: ......

Page 55: ...TIA 232 Speed and Distance Limitations As with all signaling systems EIA TIA 232 signals can travel a limited distance at any given bit rate generally the slower the data rate the greater the distance The table below gives the EIA TIA 232 speed and distance limitations Data Rate Baud Distance Feet Distance Meters 2400 200 60 4800 100 30 9600 50 15 19200 50 15 38400 50 15 57600 25 7 6 115200 12 3 7...

Page 56: ......

Page 57: ...s Pin1 Ethernet Circuit Signal 3 DO A Data Out Circuit A 10 DO B Data Out Circuit B 11 DO S Data Out Circuit Shield 5 DI A Data In Circuit A 12 DI B Data In Circuit B 4 DI S Data In Circuit Shield 2 CI A Control In Circuit A 9 CI B Control In Circuit B 1 CI S Control In Circuit Shield 6 VC Voltage Common 13 VP Voltage Plus 14 VS Voltage Shield L25 and M25 Shell PG Protective Ground 1 Any pin not r...

Page 58: ...500 500 185 100 Unshielded twisted pair UTP Media 50 ohm coax thick 50 ohm coax thick 50 ohm coax thin UTP Topology Bus Bus Bus Star Ethernet Coaxial type Connection Limits for 10 Mbps Transmission The following table lists the Ethernet coaxial type connection limits for 10 Mbps transmission Parameter 10Base5 10Base2 Cable diameter 1 cm 0 4 in 0 6 cm 0 25in Maximum segment length 500 m 1640ft 152 ...

Page 59: ...onsibility that the following equipment Brand Type Product description VYYO V290iA UHF INDUSTRIAL MODEM WITH WiFi ACCESS POINT Complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Drawn up at VYYO I...

Reviews: