background image

 

Version 1.0A 

 

UM10 User’s Guide

 

DiGi Microscope 

 

 

 

 

Summary of Contents for DiGi UM10

Page 1: ...Version 1 0A UM10 User s Guide DiGi Microscope...

Page 2: ......

Page 3: ...semble microscope with stand 2 1 3 IR Remote Control 4 1 4 Microscope Menu Functions 11 1 5 Microscope Introduction 24 1 6 Microscope Focus 27 1 7 Microscope Accessory 31 2 Printed Notice 32 2 1 Maint...

Page 4: ...d 1 HDMI Cable 1 IR Remote Control 1 USB C Cable 1 User s Guide 1 Power adaptor 1 Calibrator 1 S107 Stand 1 Object Lens 4x 1 Stand assemble guide 1 Object Lens 10x Option Micro SD Card Option Software...

Page 5: ...3 1 2 2 Start to use microscope Connect the HDMI cable b and adaptor c to HDMI monitor and power Microscope will turn on when Power in a b c...

Page 6: ...put image 1 3 IR Remote Control The microscope operation and functions is controlled by the IR remote control Long press means press and hold the button for 2 seconds 1 Power Turn on off 2 HDMI Pictur...

Page 7: ...n to the situation before turn off 6 Motor Reset Recalibrates entire operation Returns to the lens position If a loss of electricity occurred during operation please reset the operation 7 Manual focus...

Page 8: ...previous item if Crosshair is ON select other color In Playback mode press to enter next 10 files 12 Down Choose the next item if Crosshair is ON select other color In Playback mode press to enter la...

Page 9: ...and Working Distance WD or ON OFF the status The area e tells the operation status and only show 3 seconds 16 1 Area d 16 1 1 FOV Field of View FOV display image on the effective horizontal size of s...

Page 10: ...means search focus in current area 500 means sensor position AFS W500 W means search focus in whole area 16 2 4 AFC Continuous autofocus A and W are same function as AFS 16 2 5 LED LED levels Ex LED...

Page 11: ...ins 16 3 3 12 30 IMG_000012 Picture Playback mode 16 3 4 15 20 VID_000015 Video Playback mode 16 4 Function mode g Show the current operate mode 16 4 1 PC CAM able to connect with PC software and prev...

Page 12: ...To calibrate the white balance place the white balance card under the lens focus until clear and press AWB Sometimes the white balance is influenced by external light sources it is recommended to cal...

Page 13: ...wn to choose item Left and Right to turn on off or adjust parameter Enter means more functions press Menu to enter next function or confirm Return is Return to last page or press Left or Right to choo...

Page 14: ...tain optimum detail in both the shadows and highlights of the image 4 DEFOG De Fog When observing under strong light or special environment use Defog function to see clear image Below fig for De Fog s...

Page 15: ...LC Back Light Compensation To adjust brightness for darker image in back light environment 2 1 BLC Gain To adjust brightness level 2 2 Area Select Choose the back light compensation area and size 2 3...

Page 16: ...o calibrated 3 AWC SET Semi auto white balance Use to track the white color from current image Same as 1 3 17 operation 4 MANUAL Manually adjust blue and red values to find correct white color Refer t...

Page 17: ...15 2 3D NR ON OFF Motion Adaptive 3D NR Set Noise Reduction level 3 RETURN Choose from RETURN EXIT Auto Save Setting or Return Exit without Save setting 1 4 5 SPECIAL Set special functions...

Page 18: ...ff 1 1 Video Freeze ON OFF to freeze image 1 2 Mirror Image rotatory Horizontal or Vertical 1 3 Zoom Digital zoom in the selected area Zoom size from x1 x4 1 3 1 Zoom Select digital zoom 1 3 2 Horizon...

Page 19: ...Image Stabilization function 1 4 1 LEVEL Select Stabilization level 1 4 2 RETURN Choose from RETURN EXIT Auto Save Setting or Return Exit without Save setting 1 5 RETURN Choose from RETURN EXIT Auto S...

Page 20: ...rea 2 2 Sensitivity The sensitivity to detect whenever object moves The lower value gets the higher sensitivity 2 3 DEFAULT Return to factory setting 2 4 RETURN Choose from RETURN EXIT Auto Save Setti...

Page 21: ...Lines on the display Calibrate the line distances by using calibrator The calibrated lines can be reference scale 3 1 Horizontal 3 1 1 ON OFF Display the Horizontal line 3 1 2 Position Set the first h...

Page 22: ...Display the Vertical line 3 2 2 Position Set the first vertical line as origin 3 2 3 Size Line width 3 2 4 Color Black White Yellow Blue Green Pink Red and Blue 3 2 5 Count Show count numbers Maximum...

Page 23: ...e Suggest not to change this setting 4 1 1 LEVEL Set the threshold value to judge if compensation is needed 4 1 2 DEAFULT Return to factory setting 4 1 3 RETURN Return to last page or Save End Menu 4...

Page 24: ...rn Exit without Save setting 6 VERSION Firmware version 7 Format SD Card Format SD Card when using new one or unable to recognize the current one Format in FAT32 format in order to have better file co...

Page 25: ...ration 3 Contrast Adjust image contrast 4 DEFAULT Return to factory setting 5 RETURN Choose from RETURN EXIT Auto Save Setting or Return Exit without Save setting 1 4 7 Video Adjust Reset all paramete...

Page 26: ...transparent protection sheet on the IR receiver area 1 IR remote control aiming area f The indicator will blink whenever buttons are pressed If the indicator did not blink means the signal was not del...

Page 27: ...icroscope and do not disassemble cables forcefully 1 HDMI i The HDMI port is used to connect the microscope to a screen When the device is in HDMI mode connect the microscope to the screen using the H...

Page 28: ...2 Stand gear box Assemble the stand and then screw the microscope onto the universal joint m on the gear box 1 5 3 LED Light socket 1 LED n Provides luminance for object lens 4x total 30 LEDs 2 Light...

Page 29: ...to adjust the microscope height then tuning focus by remote controller until clear On the contrary first to choose the image sensor position then adjusts the microscope height Focus distance distance...

Page 30: ...remote controller or far distance control mode on the application program to focus the image 2 Fixed image sensor position The status bar will show on the screen please refer to Section 1 3 16 Use th...

Page 31: ...have 14 focus sections The sensor position tells the magnification size Mag field of view FOV or working distance WD The below chart is measured on 4 3 ratio on 24 screen it s only a reference data m...

Page 32: ...2 15 1 17 7 21 2 26 5 29 5 33 2 35 4 37 9 Focus section 10 11 12 13 14 15 16 17 18 Sensor position 1280 1240 1190 1130 1095 1055 1015 965 910 WD mm 70 5 65 5 60 0 55 0 52 0 49 5 47 0 44 0 41 5 FOV mm...

Page 33: ...6 FOV mm 2 3 2 2 2 1 2 0 1 9 1 8 1 7 1 6 1 5 Mag X 231 242 253 266 280 295 313 332 354 Focus section 10 11 12 13 14 Sensor position 815 625 400 135 45 WD mm 7 3 7 0 6 7 6 4 6 3 FOV mm 1 4 1 3 1 2 1 1...

Page 34: ...lfunction if it encounters strong collision vibration or distortion 2 1 4 Turn the microscope off before cutting off the power supply do not forced cut off the power supply 2 1 5 Do not face the lens...

Page 35: ...y source White LED 30pcs DC port Adaptor DC Input HDMI port Output 1080P 1920 1080 Pixel image Focus control IR remote control Power supplier Adaptor Output DC 5 0V 2 0A Input AC 100 240V 50 60Hz Powe...

Page 36: ...e the device or the device is dropped or damaged please switch off and remove the power supply to avoid fire and electric shock Do not look steadily into Light sources after switching on the host as i...

Page 37: ...r etc Services caused by any of the following situations in the period of the warranty shall not be provided free of charge 1 Improper use or disassembly repair or refitting 2 Any damages to the devic...

Page 38: ...Confirmation Stamp is necessary for validation of the Warranty Distributor s seal shall include name of the shop telephone and address Please ask the distributor to fill in the name of the shop addres...

Page 39: ......

Page 40: ...HTTP WWW VITINY COM MicroLinks Technology Corp All rights reserved...

Reviews: