1. INTRODUCTION

1. INTRODUCTION

1. INTRODUCTION

1. INTRODUCTION    

The  TOWER-32AM  PG2  and  TOWER-32AM  K9-90  PG2  (pet-immune)  Dual  Technology  are  2-way, 
microprocessor-controlled,  wireless  digital  mirror  PIR  detectors  interfacing  with  PowerMaster-10  and 
PowerMaster-30 control panels (version 16 and higher) and which include the following features: 

  Adaptive  Active  Infra-Red  Anti-Masking  technology  providing  the  most  advanced  reliable  protection 

against intentional masking attempts (patent pending) 

  Includes a fully supervised PowerG transceiver. 

  24 GHz K-band microwave module. 

  Incorporates patent pending black mirrors for extremely high white light immunity. 

  Advanced elliptical / parabolic mirror technology (patent pending) 

  Provides multiple curtain coverage (patent pending) 

  V-slot® optic technology (patent pending) for improved robustness, anti-vandalism and for very high reliability. 

  Creep zone protection 

  TOWER-32AM K9-90 PG2 can distinguish between human beings and pets weighing up to 

40 kg (90 lb)

  The  advanced  True  Motion  Recognition

™ 

algorithm  (patented)  allows  distinguishing  between  the  true 

motion of an intruder and any other disturbances which may cause false alarms. 

  Built-in auto diagnostic for both PIR and microwave detectors. 

  Built-in  link  quality  indicators;  no  need  for  the  installer  to  physically  approach  the  control  panel  thus 

making installation faster and easier. 

  No vertical adjustment is needed. 

  Motion event counter determines whether 1 or 2 consecutive motion events will trigger an alarm. 

  Automatic termination of walk-test after 15 minutes. 

  Microprocessor controlled, digital TMR signal processing with dual-slope digital temperature compensation. 

  Sealed chamber protects the optical system. 

  Front and back tamper protection. 

  Microwave anti-masking 

  Disguise mode that detects an intruder who cloaks his IR radiation

.

 

C

B

A

 

A.

 Screw cover 

B.

 LED  

C.

 PIR optical window 

Figure 1. General View

 

2

2

2

2. 

. INSTALLATION

INSTALLATION

INSTALLATION

INSTALLATION    

2.1 General Guidance

 (see Fig. 2) 

1. Keep away from heat sources. 

2. Do not expose to air drafts. 

3. Do not install outdoors. 

4. Avoid direct sunshine.

 

5. Keep wiring away from power cables. 

6. Do not install behind partitions. 

7. Mount on solid stable surface.

 

8. Install the detector in an upright position. 

 

WARNING!

 To comply with FCC and IC RF exposure compliance 

requirements, the PIR detector should be located at a distance of 
at least 20 cm from all persons during normal operation. The 
antennas used for this product must not be co-located or operated 
in conjunction with any other antenna or transmitter

 

1

2

3

4

5

6

7

 

Figure 2. General Guidelines 

 

Important! 

The detector is immune to 

40 kg (90 lb)

 

animals  moving  on  the  floor  or  climbing  on 

furniture as long as the activity takes place below 

1 m (3 ft). Above the 1 m (3 ft) height limit, the pet 

immunity  will  decrease  as  the  pet  gets  closer  to 

the detector. It is therefore recommended to select 

a mounting location that minimizes potential close 

proximity of animals. 

 

 

 

Summary of Contents for TOWER-32AMPG2

Page 1: ...ectors Built in link quality indicators no need for the installer to physically approach the control panel thus making installation faster and easier No vertical adjustment is needed Motion event counter determines whether 1 or 2 consecutive motion events will trigger an alarm Automatic termination of walk test after 15 minutes Microprocessor controlled digital TMR signal processing with dual slop...

Page 2: ...table Use adequate mounting means to secure the detector to the mounting surface for example when installed on drywall use the supplied plastic anchors At least 2 screws are required for the installation 6 1 8 7 2 1 8 2 4 9 2 7 10 3 0 ft m b a b b a a b b a a a b b b b b 15 6 30 9 45 12 60 ft 15 m A B a upper surface without downward tilt b lower surface with downward tilt 5 6 D E F Figure 3 Mount...

Page 3: ...ng the detector on the ceiling 1 Remove the front cover as shown in Figure 3 points 2 and 3 2 Punch out the selected knockout in the bracket see Figure 3 point 4 3 Assemble the bracket as shown in Figure 4 4 Rotate the bracket to the desired position but do not yet tighten the screw fully 5 Press the bracket base against the mounting surface and mark the points for drilling Drill out the holes and...

Page 4: ...f an intruder who cloaks his IR radiation to avoid detection Define whether to enable or disable this mode Optional settings disabled default and enabled 3 3 3 3 LOCAL LOCAL LOCAL LOCAL DIAGNOSTICS TEST DIAGNOSTICS TEST DIAGNOSTICS TEST DIAGNOSTICS TEST A Separate the base from the cover see Fig 3 B Put back the cover to return the tamper switch to its normal undisturbed position and then secure t...

Page 5: ...ing measures Re orient or re locate the receiving antenna Increase the distance between the device and the receiver Connect the device to an outlet on a circuit different from the one that supplies power to the receiver Consult the dealer or an experienced radio TV technician WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the...

Page 6: ...rest of world 433 434 868 869 USA 912 919 Communication Protocol PowerG Supervision Signaling at 4 min intervals Tamper Alert Reported when a tamper event occurs and in any subsequent message until the tamper switch is restored MOUNTING Height 1 8 3 0 m 6 10 ft Installation Options Surface or corner ACCESSORIES BR 1 Surface mounted swivel bracket adjustable 30 down and 45 left 45 right BR 2 BR 1 w...

Reviews: