background image

1

MODEL

VEDV900

EXTERIOR

BLOWER

10" ROUND DUCT

TO

DOWNDRAFT

WARNING

READ   AND   SAVE   THESE   INSTRUCTIONS

MODEL VDVE900

 

EXTERIOR MOUNTED

 

BLOWER

FOR USE WITH MODELS VDD5300, CVDD5300, VDD5360, CVDD5360, VDD5450, 
CVDD5450, VDD5480, CVDD5480 DOWNDRAFT VENTILATORS.

TO REDUCE THE RISK OF FIRE, ELECTRIC 

SHOCK, OR INJURY TO PERSONS, OBSERVE 

THE FOLLOWING:

1. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the 

manufacturer or your distributor.

2.  Before servicing or cleaning unit, switch power off

at service panel and lock the service disconnect-

ing means to prevent power from being switched 

on accidentally. When the service disconnecting 

means cannot be locked, securely fasten a prom-

inent warning device, such as a tag, to the service 

panel.

3.  Installation work and electrical wiring must be done

by a qualified person(s) in accordance with all ap-

plicable codes and standards, including fire-rated 

construction codes and standards.

4.  Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of 

fuel burning equipment to prevent backdrafting. Fol-

low the heating equipment manufacturer's guideline 

and safety standards such as those published by 

the National Fire Protection Association (NFPA), 

and the American Society for Heating, Refrigeration 

and Air Conditioning Engineers (ASHRAE), and 

the local code authorities.

WARNING

CAUTION

1. For general ventilating use only. Do not use to ex-

haust hazardous or explosive material and vapors.

2. To avoid motor bearing damage and noisy and/or

unbalanced impellers, keep drywall spray, con-

struction dust, etc. off power unit.

3.  Please read specification label on product for further

information and requirements.

4.  Electrical circuit, including speed control, (if used), 

must be rated 6 AMPS minimum.

Blower Dimensions

28.25 x 24.75 x 7.17

PLAN THE
INSTALLATION

1. Locate the blower so the

length of the duct run and

number of elbows needed

are kept to a minimum.

2. Where possible, blower

should be centered between

wall studs or roof rafters.

3. Avoid pipes, wires, or other

ductwork that may be run-

ning through the wall.

ALL INSTALLATIONS

MODEL  VOLTS  AMPS 

CFM 

DUCT SIZE

VDVE900 

120 

5.7 

900 

10 " DIA.

SPECIFICATIONS

5.  When cutting or drilling into wall, or ceiling, do not

damage electrical wiring or other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.

MODEL VEDV900

EXTERIOR BLOWER

10" ROUND

DUCT

TO

DOWNDRAFT

TYPICAL ROOF MOUNTED INSTALLATION

TYPICAL

WALL MOUNTED INSTALLATION

INSTALLER: Leave This Manual With The Homeowner

HOMEOWNER: Use And Care Information On Page 4

MODEL VDVE900

EXTERIOR BLOWER

MODEL 

VDVE900

EXTERIOR 

BLOWER

Summary of Contents for VDVE900

Page 1: ...A andtheAmericanSocietyforHeating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities WARNING CAUTION 1 For general ventilating use only Do not use to ex haust hazardous or explosive material and vapors 2 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray con struction dust etc off power unit 3 Pleasereadspecificationlabelonproduct...

Page 2: ...inds 20 103 8 8 20 7 1 dia hole 91 8 Roof Rafter REMOVE SHINGLES 11 dia hole Roof Rafter Pilot Hole Pilot Hole OUTSIDE ROOF VIEW From inside the attic space 2 Drill a PILOT HOLE up through the roof 8 from the inside edge of a ROOF RAFTER From outside on the roof 3 Measure and mark the 20 x 20 rectangle Cut and remove only the shingles inside this rectangle 4 Measure and mark the 11 DIAMETER HOLE a...

Page 3: ...manual for instructions to connect wiring to downdraft electrical panel 1 Place a large bead of caulk on the back side of the housing along the outer edge 2 Center the blower ring in the 11 diameter hole making sure that the 1 1 4 diameter electrical wiring hole aligns with the hole in the wiring box 3 Attach blower to the wall with the six screws pro vided All six holes in the back panel must be ...

Page 4: ...reful not to bend or otherwise damage blower wheel MOTOR LUBRICATION The motor is permanently lubricated Do not oil or disassemble motor CONNECT 10 ROUND DUCTWORK 2 Refer to downdraft ventilator manual for instructions on how to Locate and cut holes in cabinet Attach 10 round duct and rough in plate to downdraft 1 Connect 10 round ductwork to blower Run ductwork to downdraft location NOTE Use duct...

Page 5: ...ocales 5 Veillez à ne pas endommager le câblage électrique ou d autres équipements non apparents lors de la découpe ou du perçage du mur ou du plafond AVERTISSEMENT ATTENTION 1 Cet appareil ne doit servir qu à la ventilation générale Ne l utilisez pas pour éliminer des matières ni des vapeurs dangereuses ou explosives 2 Pour éviter d endommager les roulements de moteur de déséquilibrer les pales o...

Page 6: ... et un ORIFICE D UN DIAMÈTRE DE 32 MM 1 PO Découpez ces orifices de part en part du toit 521 mm 20 1 2 po 264 mm 10 3 8 po EXTÉRIEUR VUE DU TOIT 527 mm 20 po 216 mm 8 po 184 mm 7 po Orifice d un diamètre de 32 mm 1 po Orifice d un diamètre de 279 mm 11 po ENLEVEZ LES BARDEAUX Avant trou Chevron Chevron ILLUSTRATION 1 POSES SUR LES MURS PRÉPARATION DU VENTILATEUR TOUS LES TYPES DE POSE 1 Déballez l...

Page 7: ...uez une large bande de produit à calfeutrer à l arrière du boîtier le long du rebord extérieur 2 Centrez l anneau de ventilateur dans le trou de 27 9 cm 11 po de diamètre en s assurant que l orifice pour le câblage électrique de 3 2 cm de diamètre 1 po coïncide avec l orifice dans le boîtier de câblage 3 Fixez le ventilateur au toit à l aide des six fournies Tous les six trous du panneau arrière d...

Page 8: ... moteur est lubrifié en permanence Il ne doit pas être huilé ni démonté RACCORDEMENT DU CONDUIT ROND DE 25 4 CM 10 PO 2 Reportez vous au guide du ventilateur à tirage vers le bas pour Localiser et couper des orifices dans l armoire Raccordez le conduit rond de 25 4 cm 10 po et plaque de première oeuvre au ventilateur à tirage vers le bas 1 Raccordez le conduit rond de 25 4 cm 10 po au ventilateur ...

Page 9: ...nado American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE y las autoridades de los códigos locales ADVERTENCIA PRECAUCIÓN 1 Sólo para usarse como medio de ventilación general No lo useparaextraermaterialesnivaporespeligrososoexplosivos 2 Para evitar daños a los cojinetes del motor y rotores ruidosos odesbalanceados mantengalaunidaddepotenciaprotegida contra rociados de ...

Page 10: ... Viga del techo Orificio piloto Orificio piloto EXTERIOR VISTA DEL TECHO Orificio de 1 pulg 3 2 cm de diám 8 pulg 21 6 cm 10 3 8 pulg 26 4 cm 20 pulg 52 1 cm 20 pulg 52 7 cm 7 pulg 18 4 cm Orificio de 11 pulg 27 9 cm de diám Desde el interior del espacio del ático 2 Haga un ORIFICIO PILOTO a través del techo a una distancia de 8 pulg 21 6 cm del borde interior de una VIGA DEL TECHO Desde el exteri...

Page 11: ...el ventilador de tiro descendente 1 Coloque un reborde grande de material de calafateo en el lado posterior de la cubierta a lo largo del borde externo 2 Centre el anillo del ventilador en el orificio de 11 pulg 27 9 cm asegurándose de que el orificio del cableado eléctrico de 1 pulg 3 2 cm de diámetro quede alineado con el orificio de la caja de conexiones 3 Monte el ventilador en la pared con lo...

Page 12: ...UBRICACIÓN DEL MOTOR El motor está permanentemente lubricado No lubrique ni desarme el motor CONECTE EL CONDUCTO REDONDO DE 10 PULG 25 CM 2 Consulte las instrucciones del manual del ventilador de tiro descendente para Encontrar y cortar los orificios en el gabinete Conectar el conducto redondo de 10 pulg 25 cm y la placa preliminar al tiro descendente 1 Conecte el conducto redondo de 10 pulg 25 cm...

Reviews: