Page 1: ...I N S T A L L A T I O N A N D U S E R M A N U A L G S M V O H 1 0 0 1 ...

Page 2: ... S u p p o r t s ar m an d d i s ar m b y A p p S u p p o r t s r e m o t e m o n i t o r b y A p p S u p p o r t s r e m o t e c o n t r o l ar m d i s ar m m o n i t o r b y p h o n e S M S f o r p o w e r p o w e r r e c o v e r y an d l o w S u p p o r t s g l o b a l G S M 85 0 90 0 1 80 0 1 90 0 M H z C o n tro l P an e l F e atu re s F e atu re s 1 S tatu s L o w P o w e r I n d i c ato r B...

Page 3: ...numbers When you pick up the phone control the panel from distance according to the in the table below Method 2 1 Dial the telephone number of the SIM card in your control panel 2 Enter your user code followed by ey you press on your phone you hear one beep 3 Select the to control the panel see in the table below Note The call will end ally if you do not send any command within 30 seconds Voice Co...

Page 4: ...ur home without triggering an alarm Refer to the on page 6 of this manual to learn how to set the entry and exit delay It is recommended to assign the Door Window Contact to the Delay zone Home zone When the system is armed in Home Mode the sensors assigned to the Home zone do not trigger an alarm It is rec armed in Home Mode when you are home and move inside your home without triggering any alarm...

Page 5: ...set up the system Store Phone Numbers Send 5 Phone numbers 1 2 3 4 5 Copy Paste then Edit case e Phone numbers 1 067890033 2 067890022 3 067890011 4 067890000 5 Ok ChangeZoneName Send 91 99 For example for zone 1 send 91 Zones names 1 Copy Paste then Edit case e Zones names 1 Entrance door alarm Ok Note Zones 1 to 9 can be renamed The name of the zone cannot consist of more than 30 characters per ...

Page 6: ...amper alarm Entry and Exit Delay Time Send 11 Entry delay Exit delay Copy Paste then Edit case Entry delay Exit delay Ok Note This can be used if you do not want to bring a remote control or RFID tag with you When the system is armed you hear one beep every second to remind you to leave The beep rhythm speeds up during the last 10 seconds If an intruder is detected the alarm will be delayed accord...

Page 7: ... numbers and connected accessories will also be deleted Only stored numbers can send the SMS to restore factory Accessories Wireless Remote Control Home Mode Arm SOS Disarm LED indicator Arm the system Press the Arm to arm the alarm system The LED indicator lights up the siren rings out once The system is armed If an intruder is detected the siren rings out The siren turns 5 minutes as per default...

Page 8: ...tures 3 1 2 1 LED indicator 2 Detection window 3 Bracket PCB Layout Alarm zone setup Tamper switch Infrared sensor AA 1 5V LR6 Antenna LED working indicator Tamper switch When the alarm system is armed the tamper switch will trigger the alarm if the case is opened Infrared sensor Detects the infrared rays released by human body Do not touch the surface Keep the surface clean LED Blinks self Blinks...

Page 9: ... the bracket on the wall with screws and ach the detector to the bracket Adjust the bracket to change the det distance and angle It is recommended to mount the detector 2m from the ground Top Ground 2 2 m The detector is more sensitive to cross movements than vertical movements Side view Top view A the inst turn the detector on one minute of self t press the test walk in the scope of det and watch...

Page 10: ...gain by opening the door or window on which it is installed If the siren rings out the regis is successful Open the case and remove the ery strip Mount the sensor on the door and the magnet on the door frame Make sure the magnet is placed above the er Mount the magnet max 1 cm away from the and secure the and magnet with double sided tape or screws Avoid the sensor in areas with a large amount of ...

Page 11: ...20 21 This keyboard enables you to arm and disarm your alarm system or arm it in Home Mode 27 ...

Page 12: ...22 23 It ...

Page 13: ...24 25 The MS 10A operates under 4modes ...

Page 14: ...26 27 Maxsmart Maxsmart Maxsmart Maxsmart It ...

Page 15: ...28 29 ...

Page 16: ...30 31 ...

Page 17: ...32 33 Maxsmart ...

Page 18: ...34 35 ...

Page 19: ...36 37 ...

Page 20: ...s are potentially dangerous for the environment and human heath due to the presence of hazardous substances In compliance with European law This product was designed and manufactured in compliance with Directive 2002 95 EC of the European Parliament and of the Council on the restriction of use of certain hazardous substances in electrical and electronic equipment RoHS Directive Rohs and is deemed ...