background image

Operating Instructions

Vitotrol 300

Remote control for one heating circuit

Part No. 7133 382

Vitotrol 300

Certified as a component part

of Viessmann boilers only

Pl

ease

fi

le

in

Ser

v

ic

e

B

inder

5167 505 01/01

Summary of Contents for Vitotrol 300

Page 1: ...erating Instructions Vitotrol 300 Remote control for one heating circuit Part No 7133 382 Vitotrol 300 Certified as a component part of Viessmann boilers only Please file in Service Binder 5167 505 01 01 ...

Page 2: ...portant Regulatory and Installation Requirements H Advice to owner Once the installation work is complete the heating contractor must familiarize the system operator ultimate owner with all equipment as well as safety precautions requirements shut down procedure and the need for professional service annually before the heating season begins Warranty Information contained in this and related produc...

Page 3: ...de 11 Activating the energy saving mode 11 Operating Instructions Space Heating Adjustments Accessing Altering the time program for space heating 12 Domestic Hot Water Production Adjustments Accessing Altering the time program for domestic hot water production 14 Altering domestic hot water temperature 17 Altering the time program for the DHW recirc pump 18 When you go on holidays Setting the ener...

Page 4: ... in minor injury or product property damage Helpful hints for installation operation or maintenance which pertain to the product This symbol indicates that additional pertinent information is to be found in column three This symbol indicates that other instructions must be referenced 5 1 6 7 5 0 5 Warnings draw your attention to the presence of potential hazards or important product information WA...

Page 5: ...nvironment e g 68 ºF 20 ºC 2 Reduced room temperature at nighttime or for the times you spend away from home To save energy this room temperature is set lower than the normal room temperature At the time of delivery frost protection is set to 37 ºF 3 ºC You can select the time and duration of the room temperature on your programming unit The desired room temperature can be selected for both normal...

Page 6: ...ntrol and press at the same time press or to adjust the contrast Illumination of the display window If the supplied batteries have been inserted illumination is activated after pressing any given button and deactivated approx 30 seconds after your last operation Factory default setting When altered values must be reset to the factory default setting Take note that all values are reset to the facto...

Page 7: ...g mode is set to Heating and Domestic Hot Water i e space heating and domestic hot water heating takes place according to the heating cycle Heating cycles Space heating with normal room temperature takes place between 06 00 and 22 00 hrs domestic hot water heating if DHW tank installed takes place between 05 30 and 22 00 hrs Frost protection takes place between 22 00 and 06 00 hrs 37 ºF 3 ºC 5 1 6...

Page 8: ... entering the date 6 to confirm 7 Close flip down cover of remote control Language Selection English is factory preset as the operating language You may choose the language of your preference Outside Temp i ºC English i 1 Open flip down cover of remote control 2 to scan outside temperature is displayed 3 until desired language appears 4 to confirm display now indicates the time 5 Close flip down c...

Page 9: ...lled and DHW recirculation pump if installed according to set DHW cycle H Frost protection of the heating circuit Domestic hot water production only H no space heating H domestic hot water heating if DHW tank installed and DHW recirculation pump if installed according to set DHW cycle H Frost protection of the heating circuit Shut off operation H no space heating H no DHW production H Frost protec...

Page 10: ... 10 and 30 ºC Adjust the desired temperature at dial The temperature appears in the display window Example For a comfortably warm living environment Altering reduced room temperature Frost Protection ºC Reduced Room Temp ºC Factory default setting Frost protection 37 ºF 3 ºC from 22 00 to 06 00 hrs Reduced room temperature is adjustable between 37 and 99 ºF 3 and 37 ºC 1 Open flip down cover of re...

Page 11: ...cover of remote control 2 Press the temperature preset at dial will flash 3 Select desired temperature by pressing or 4 To confirm press the temperature shown stops flashing and is saved 5 Close cover of remote control End party mode H The party mode will end with the next automatic switching to space heating with normal room temperature H If you would like to end the party mode prematurely press ...

Page 12: ...me heating cycles for each day of the week Time Prog Heating 1 7 1 1 7 11 Open flip down cover of the remote control 12 for Time Prog Heating wait until display on the left appears 13 for Heating Cycle 1 14 for Heating Cycle 1 On 15 for setting the start of Cycle 1 16 to confirm the display switches to Heating Cycle 1 Off 17 for setting the end of Cycle 1 18 to confirm the display changes to Heati...

Page 13: ...he heating cycle 19 to confirm the display changes to Heating Cycle 2 On 10 For setting starting and ending times for Cycles 2 to 4 proceed as described in steps 6 to 10 11 Close flip down cover of remote control Accessing heating cycles Proceed as described above with the exception of pressing buttons and Overview of heating cycles 1 Open flip down cover of remote control 2 Press and simultaneous...

Page 14: ... domestic hot water production on a one time basis and outside of the programmed heating cycles e g after 22 00 hrs press see section Setting the Party Mode twice with approx 2 to 3 seconds in between Setting the same heating cycles for each day of the week Automatic Time Prog DHWTime 1 7 1 Open flip down cover of remote control 2 for time program Time Prog DHW wait until display shown on the left...

Page 15: ...ting Cycles Proceed as described on previous page with the exception of pressing buttons and Overview of heating cycles 1 Open flip down cover of remote control 2 Press and simultaneously the selected cycles are shown on a time line 3 Close flip down cover of remote control 5 1 6 7 5 0 5 ...

Page 16: ... Cycle 1 7 for DHW Heating Cycle 1 On 8 for entering the start of Cycle 1 9 to confirm the display will switch to DHW Heating Cycle 1 Off 10 for entering the end of Cycle 1 11 to confirm the display switches to DHW Heating Cycle 2 On 12 For setting starting and ending times for Cycles 2 to 4 proceed as described in steps 6 to 10 13 Close flip down cover of remote control If you would like to termi...

Page 17: ... the week are shown on the time line 3 Close flip down cover of remote control Altering Domestic Hot Water Temperature Select the domestic hot water temperature according to your personal preference Be sure to reference information in section entitled Basic Heating Technology Know How DHW Temp Setpoint ºC 1 Open flip down cover of remote control 2 for DHW temperature temperature flashes 3 for ente...

Page 18: ...ach day of the week Automatic Time Prog DHW Recirc Pump1 1 7 1 1 7 1 Open flip down cover of remote control 2 for Time Program DHW Recirculation Pump wait until display shown on the left appears 3 for Individual 4 to confirm 5 for DHW Recirculation Pump Cycle 1 6 for DHW Recirculation Pump Cycle 1 On 7 for entering the start of Cycle 1 8 to confirm display switches to DHW Recirculation Pump Cycle ...

Page 19: ...lation Pump Cycle 1 Off 10 for entering the end of Cycle 1 11 to confirm the display switches to DHW Recirculation Pump Cycle 2 On 12 For setting starting and ending times for Cycles 2 to 4 proceed as described in steps 6 to 10 13 Close flip down cover of remote control Accessing heating cycles Proceed as describe above with the exception of pressing buttons and Overview of heating cycles 1 Open f...

Page 20: ...lected operating mode or only frost protection of the boiler and DHW tank is active during the holiday mode E g for indoor plant protection during your winter getaway and for a heated living environment upon your return Departure Date Sa Return Date Su 1 Open flip down cover of remote control 2 for Holiday Program 3 to confirm or automatic confirmation after four seconds display shown on the left ...

Page 21: ...ing circuit pump On Off H DHW recirculation pump On Off H Circulation Pump On Off H Language 1Only if appropriate sensor is installed Outside Temperature i ºC 1 Open flip down cover of remote control 2 to scan outside temperature is displayed 3 for further scanning 4 to end scanning display now indicates the time 5 Close flip down cover of remote control Altering Factory Default Setting Proceed as...

Page 22: ... for operation with DHW tank Priority of DHW production in display Wait until DHW tank is heated Operating modes or are selected corresponding button is lit Select operating mode the room temperature is not satis factory at a low outside temperature Heating curve adjustment at the con trol unit is incorrect Check heating curves and if necessary call your heating contractor for correction Remote co...

Page 23: ... small screw driver 2 Remove batteries from rear of remote control 3 Change batteries Use four AAA batteries Insert batteries as illustrated below 4 Mount control onto wall mount base and snap into place Recycling Batteries Rechargeable batteries should not be part of your domestic waste Please ensure that your batteries rechargeable batteries are discarded in the appropriate manner IMPORTANT 5 1 ...

Page 24: ...it H Adjust DHW temperature of the DHW tank at the control unit H Controlled use of domestic hot water Open window for a short period completely with all thermostatic valves closed Aim for a room temperature of 68 ºF 20 ºC each degree saves up to 6 heating costs E g alternating normal room temperature with reduced room temperature A shower typically requires less energy than a tub bath by performi...

Reviews: