background image

 

 

 
 

VIDAR NDT

PRO 

Industrial Film Digitizer

 

 
 
 
 
 

Installation Guide 

For Use with Windows 7, 8, & 10 

 

(Serial Numbers 370,000 to 379,999) 

 
 
 

 
 
 
 

 

 

Summary of Contents for NDT PRO

Page 1: ...VIDAR NDTPRO Industrial Film Digitizer Installation Guide For Use with Windows 7 8 10 Serial Numbers 370 000 to 379 999 ...

Page 2: ...ed 365 Herndon Parkway Herndon VA 20170 U S A Sales 1 800 471 7070 or 1 800 471 7226 Email order 3dsystems com Phone 1 703 471 7070 Fax 1 703 471 7665 Internet www vidar com Technical Support 1 800 471 7070 or 1 703 471 7070 E mail medtech 3dsystems com Emergo Europe Prinsessegracht 20 2514 AP The Hague The Netherlands E mail EmergoEurope ul com ...

Page 3: ...This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area can cause harmful interference in which case the user will be required to correct the interference at his or her own expense Product compliance testing wa...

Page 4: ...plied Parts This product provides Class I medical device protection against electrical shock WARNING To avoid the risk of electric shock this equipment must only be connected to a supply mains with protective earth Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked HOSPITAL ONLY or HOSPITAL GRADE WARNING Do not modify this equipment withou...

Page 5: ...ify the Components 11 6 If Anything Is Missing 12 7 Activate Your Product Warranty 12 Setting Up 13 1 Identify Important Features 14 2 Assemble the Digitizer 15 3 Connect the Power Cord 20 Device Driver Installation 21 Install Device Drivers for Windows 7 8 and 10 21 1 Apply Power to the Digitizer 21 2 About the VIDAR Drivers 22 3 Install the VIDAR Drivers 22 Appendix Electromagnetic Guidance 29 A...

Page 6: ...dustrial Film Digitizer Installation Guide 6 Intended Use The NDTPRO Industrial Film Digitizer is intended for making digital copies of x ray films for non destructive testing applications This device is not intended for medical use ...

Page 7: ...he digitizer s parts Identify the digitizer s parts 1 Look for Damage Before unpacking the Digitizer examine the shipping carton for damage If the carton is damaged Notify the shipper immediately Take photographs of the damage Send pictures and description of damage to medtech 3dsystems com Notify VIDAR Support at 1 703 471 7070 ...

Page 8: ...the procedure described here Failure to properly pack or failure to use VIDAR authorized shipping materials will void the product s warranty and will likely result in costly repairs Remove items from the shipping carton in the order shown below 1 Upper foam support Feeder Digitizer base Accessory box Shipping carton Leave in box lower foam support 2 3 4 Note For clarity this illustration does not ...

Page 9: ... materials by reversing the procedure described here Failure to properly pack or failure to use VIDAR authorized shipping materials will void the product s warranty and will likely result in costly repairs 3 Unpack the Accessory Box a Remove these items from the accessory box 4 Documentation in padded bag bag not shown Accessory box USB cable 1 3 Power cord Film support bar in padded bag bag not s...

Page 10: ...Then remove these items from the accessory box 5 Cardboard retainer Accessory box 7 Stand 6 Exit tray 4 Unwrap a Unwrap all items b Remove the foam block from the rear of the digitizer base Note For clarity this illustration does not show the plastic bag surrounding the exit tray ...

Page 11: ...bags foam supports and cartons Instructions for repacking are provided in the Packing the film digitizer for shipment section of this manual 5 Identify the Components Item Digitizer base Exit tray Film feeder Film support bar Stand Power cord 115V p n 4043 001 or 230V p n 2104 006 Quick setup card USB cable 6 foot p n 4618 VIDAR NDTPRO Industrial Film Digitizer CD Digitizer Base Film Feeder Exit T...

Page 12: ...rranty information card c In the Product information section record this information Digitizer serial number d Complete the form e Mail or fax the form to VIDAR Systems Corp If your digitizer needs service this information should be on file at VIDAR Contact VIDAR Technical Support if you have any questions about installing or using your VIDAR film digitizer Phone 1 800 471 SCAN 1 800 471 7226 1 70...

Page 13: ...19440 001 Rev E VIDAR NDTPRO Industrial Film Digitizer Installation Guide 13 Setting Up The digitizer must be placed on a counter or tabletop SAFETY WARNING Never place the digitizer on the floor ...

Page 14: ...es shown in this section You will need to know where these features are when you assemble the digitizer Film Feeder Screw holes Film Feeder Connector ON OFF switch a rocker switch Press I to turn power ON Press 0 to turn power OFF Digitizer base rear view Power switch and power entry module Kernel Switch Factory use USB Port ON OFF Switch Power Entry module ...

Page 15: ...ce the stand on a solid flat surface such as a table 2 Place the digitizer base on the stand as shown below Tighten the thumbscrews on the bottom of the stand to secure it to the digitizer Front view Side view Thumbscrews 2 Longer portion toward front Vent in bottom of base must be over cutout in stand Front ...

Page 16: ...the bottom of the feeder These mate to holes in the digitizer base Two of the screws are very long their tops ends are near the top of the feeder Also note the connector on the bottom of the feeder It mates to the connector on top of the digitizer base Long screw Short screw Long screw Connector Feeder rear view Feeder bottom view Top ends of long screws ...

Page 17: ...izer and slide the feeder connector into the digitizer connector c On the rear of the feeder tighten the three screws to secure the feeder to the digitizer base You may need to move the feeder slightly to get the screws started in the holes Tighten each screw a few turns then repeat until all are finger tight Screws ...

Page 18: ...izer Installation Guide 18 4 Install the exit tray by hooking it over the notched plastic edge just below the rollers When the exit tray is properly positioned it will be parallel to the roller shaft Properly installed exit tray Roller shaft Exit tray ...

Page 19: ...e film support bar Warning Before you begin the installation procedure turn off all power to the computer and peripherals Précaution Avant de commencer la connexion assurez vous que votre ordinateur soit bien éteint Advertencia Antes de continuar con la instalación favor de apagar su computadora y periférico Warnung Vor dem Installieren den Computer und angeschlossene Geräte ausschalten Front of f...

Page 20: ...o the digitizer s Power Entry Module PEM located on the rear of the digitizer 2 Connect the other end of the power cord to a grounded power outlet Note The film digitizer has an auto sensing power supply When you apply power the digitizer will detect the voltage and set itself for proper operation NEXT Device Driver Installation ...

Page 21: ...igitizer a Ensure the PC is turned off Note Always turn on the digitizer before turning on the computer This enables the computer to recognize the digitizer b Turn on the digitizer The on off switch is located on the back of the digitizer c Wait for all three LEDs on the front of the digitizer to turn green ON OFF switch a rocker switch Press I to turn power ON Press 0 to turn power OFF Digitizer ...

Page 22: ...sted on a wide range of Windows 7 8 10 systems In rare instances you may have difficulty installing the VIDAR driver If that happens try again after logging on as Administrator or as a user with Administrator rights You will need the VIDAR NDTPRO Industrial Film Digitizer CD a Be sure the digitizer is turned ON and all three LEDs are green but that it is NOT connected to the PC Wait until you are ...

Page 23: ... 001 Rev E VIDAR NDTPRO Industrial Film Digitizer Installation Guide 23 d In the first screen click Next e In the License Agreement screen activate I accept the terms of the license agreement then click Next ...

Page 24: ...40 001 Rev E VIDAR NDTPRO Industrial Film Digitizer Installation Guide 24 f In the Ready to Install the Program screen click Install g The Setup Status screen will appear Wait while the files are installed ...

Page 25: ... like to install this device software Click Install When installing on Windows 7 8 10 64 bit the name will appear as Jungo i When installing on Windows 7 8 10 32 bit the name will appear as VIDAR j InstallShield will indicate that installation is complete However the driver installation is not complete ...

Page 26: ...ait 30 seconds after you connect the digitizer before you launch the VIDARInfo program This ensures the computer has recognized the new hardware and has installed the driver properly l When using Windows 7 8 10 64 bit On the desktop double click the VIDARINFO icon m The window shown below will appear This indicates that the digitizer is communicating with the computer n Click OK if the Digitizer I...

Page 27: ...ill report as VXR 12 for backward compatibility You may not see the same firmware and hardware version as shown in the window above The serial number will not report if the digitizer was just powered on The digitizer is now ready to operate Please refer to the User s Guide for VIDAR NDTPRO Digitizers found on the VIDAR NDTPRO Industrial Film Digitizer CD for operating instructions You may need to ...

Page 28: ...de 28 In the Computer Management window the digitizer is listed under different name depending on the Bit of the OS When using Window 7 8 10 64 Bit OS the Digitizer is listed under Jungo When using Window 7 8 10 32 Bit OS the Digitizer will be listed under Imaging Devices ...

Page 29: ...nt in the actual configuration in which it will operate Caution Connecting the Digitizer to equipment that is not rated CISPR 11 class A or class B may alter the electromagnetic characteristics Caution In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Guidance and manufacturer s declaration electromagnetic equipment...

Page 30: ...s Declaration Electromagnetic Immunity Input a c power The VIDAR NDTPRO Industrial Film Digitizer is intended for use in the electromagnetic environment specified below The customer or end user of the Digitizer should assure that it is used in such an environment Immunity test Test method Immunity Test Levels Professional healthcare facility environment Electrical fast transient bursts a l o IEC 6...

Page 31: ...verter g Applicable only to ME EQUIPMENT and ME SYSTEMS connected to single phase a c mains h E g 10 12 means 10 periods at 50 Hz or 12 periods at 60 Hz i ME EQUIPMENT and ME SYSTEMS with RATED input current greater than 16 A phase shall be interrupted one for 250 300 cycles at any angle and at all phases at the same time if applicable ME EQUIPMENT and ME SYSTEMS with battery backup shall resume l...

Page 32: ...TE If necessary to achieve the Immunity Test Level the distance between the transmitting antenna and the ME Equipment or ME System may be reduced to 1 m The 1 m test distance is permitted by IEC 61000 4 3 a The carrier shall be modulated using a 50 duty cycle square wave signal b As an alternate to FM modulation 50 pulse modulation at 18 Hz may be used because while it does not represent actual mo...

Page 33: ...cation symbol Compliance to EU Directives Authorized Representative in the European Community Indicates the Device Manufacturer This symbol on the product indicates that this product must not be disposed of as unsorted municipal waste Instead it is your responsibility to dispose of your waste equipment by handing it over to a designated collection point for recycling of waste electrical and electr...

Page 34: ...365 Herndon Parkway Phone Fax Web Herndon VA 20170 1 703 471 7070 1 703 471 7665 www vidar com Technical Support Phone Email 1 703 471 7070 1 800 471 7226 1 703 471 7665 medtech 3dsystems com ...