manualshive.com logo in svg
background image

Phoenix Smart IP43 Charger

ENGLISH

Содержание Phoenix Smart IP43

Страница 1: ...Phoenix Smart IP43 Charger ENGLISH ...

Страница 2: ... mode less corrosion of the positive plates 4 4 9 Reconditioning 4 4 10 Lithium ion LiFePO batteries 5 4 11 Remote on off 5 4 12 Alarm LED 5 4 13 Automatic voltage compensation 5 4 14 Three 3 output versions 6 5 Charging algorithms 7 5 1 Battery selection 7 5 2 Lithium ion LiFePO batteries 8 5 3 Fully user programmable charging algorithm 8 5 4 If a load is connected to the battery 8 5 5 Starting a...

Страница 3: ...is device is not suitable for use by children Store the charger out of reach of children This device is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction Connection to the mains supply must be in accordance with the national regulations for electrical installat...

Страница 4: ...ct Install close to the battery but never immediately above the battery to prevent damage due to gas formation by the battery Use flexible multi core copper cables for the connections see safety instructions Poor internal temperature compensation e g ambient conditions of battery and charger not within 5 C may shorten the life span of the battery Phoenix Smart IP43 Charger Page 2 Installation ...

Страница 5: ... After selecting reconditioning the RECONDITION LED will light up and start to blink when reconditioning is active The battery charger switches to LOW low power when the MODE button is held down for 3 seconds The LOW LED will then light up and remain lit and the maximum output current will be limited to 50 of the rated output power LOW mode can be deactivated by holding the MODE button down for an...

Страница 6: ...nsated charging The optimum charging voltage of a lead acid battery is inversely proportional to the temperature The Phoenix Smart Charger measures the ambient temperature at the start of the charging phase and compensates for the temperature while charging The temperature is measured again when the battery charger is in low current mode during absorption or storage Special settings for a cold or ...

Страница 7: ...ge Protection Important note NEVER attempt to charge a lithium ion battery if the temperature of the battery is below 0 C 2 Low battery temperature cut off This will stop charging lithium batteries below 5 C default May require VE Smart networking temperature sensor e g Smart Battery Sense or SmartShunt 4 11 Remote on off There are three ways to switch on the device 1 Short the L and H pins factor...

Страница 8: ...calculated with the following formula U I x Rtotal In which U is the voltage drop in volts V and I is the current through the wire in amperes A The voltage drop will then be U 50 x 2 96mΩ 148mV for the full 50A charging current 4 14 Three 3 output versions The three output version chargers have an integrated FET battery isolator and therefore feature three isolated outputs Although all outputs can...

Страница 9: ... button is held down for another 3 seconds When LOW is active the output current is limited to max 50 of the rated output power Intelligent 7 stage charging algorithm for lead acid batteries with optional reconditioning 1 BULK Charges the battery using the maximum current until the absorption voltage is reached At the end of the bulk phase the battery will be about 80 charged and ready for use 2 A...

Страница 10: ...u can also program your own charging algorithm using Bluetooth or the VE Direct interface If a self programmed charging algorithm is selected the NORMAL HIGH and LIION LEDs will not be lit The status LEDs indicate the location of the charging program in the charger If the MODE button is pressed during a self programmed charging algorithm the charger will return to the pre programmed NORMAL chargin...

Страница 11: ...face When used as a power supply only the BULK ABSORPTION FLOAT and STORAGE LEDs will light up and remain lit When the charger is set up as a power supply it will not respond to the remote on off If the MODE button is pressed while using the charger as a power supply it will return to the pre programmed NORMAL charging algorithm Phoenix Smart IP43 Charger Page 9 Charging algorithms ...

Страница 12: ... 25 A Low current mode 15 25 A 15 25 A 8 12 5 A 8 12 5 A Charge current starter battery 3 A 1 1 output models only Charge algorithm 7 stage adaptive 3 stage adaptive for Li ion Battery capacity 150 300 Ah 30A version 250 500 Ah 50A version 80 160 Ah 16A version 125 250 Ah 25A version Number of battery connections 2 3 2 3 Protection Battery reverse polarity fuse not user accessible Output short cir...

Страница 13: ... 3 outputs 24 16 3 24 25 3 Dimensions hxwxd 180 x 249 x 100 mm 7 1 x 9 8 x 4 0 inch STANDARDS Safety EN 60335 1 EN 60335 2 29 Emission EN 55014 1 EN 61000 6 3 EN 61000 3 2 Immunity EN 55014 2 EN 61000 6 1 EN 61000 6 2 EN 61000 3 3 Vibration IEC68 2 6 10 150Hz 1 0G Phoenix Smart IP43 Charger Page 11 Technical specifications ...

Страница 14: ...7 Dimensions Phoenix Smart IP43 Charger Page 12 Dimensions ...