background image

. The basic parameters :

Model

Dimensions

(mm)

Power

Kw

Voltage

V

Switching few

LD-610

665*470*220

3.2

110

Group 2

LD-450

460*400*220

1.6

110

Group 1

LD-821

540*400*220

1.6

110

Group 1

LD-820

730*480*230

3

110

Group 2

LD-818A

540*400*220

1.6

110

Group1

LD-818B

360*390*220

1.5

110

Group 1

LD-822

730*480*230

3

110

Group 2

.Transportation and custody:

During the process, the products should be mistreated, to prevent severe

shock, packaging products generally not a good long-term outdoor storage,

take a well-ventilated, non-corrosive gases within the warehouse, not

inverted, the need for temporary storage, resistant measures should be

adopted.

.Installation location and attention

1.The products should be on smooth, Unbarring left side about 10cm above

objects, should back away from Unbarring - 20cm above.

2.Cut hasty inflammable goods (such as towels, etc.) on the lining, this may

cause a fire burning incidents.

3.The equipment used in power supply voltage must be the product

nameplate supply voltage line.

4.Users need in the vicinity of the fixed equipment supply road and opened

with a contact from the entire ≥ 3m very disconnected devices and leakage

protection switch is not allowed in front of owning.

5.The use of the equipment must be safe before the grounding.

6.Replacement power line should use the same cable, and requested the

replacement of professionals.

7.Before use of the product should check the electrical components

connected whether solid, reliable safety grounding.

.The use of methods:

1.Temperature control device installed in front of products, used to control

the heating plate heat temperature, thereby ensuring serving plate

temperature

2.Power Up, Green-light, rotating clockwise direction respectively

temperature control device, the temperature of the temperature required for

alignment position, this bright orange light, power has for the rest of the

furnace, heat pipe to start work, when the temperature of the required

temperature, temperature control device can automatically cut off the power

supply, while orange color light exterminated, heating stop. When the

temperature dropped slightly, temperature control device can automatically

connected power, orange indicator light, heat pipe heat recovery, an increase

in temperature, so repeated cycle to ensure that the set temperature within

constant. If necessary, adjust to the required temperature, the food will be

produced the desired results.

3.Use oil to a timely liquidation of oil to prevent overflow.

4.Use process, anomalies should immediately stop using the inspection

troubleshooting, before use.

.Cleaning and maintenance:

1.In a clean maintenance, the power supply should be cut off to prevent

accidents.

2.Every day after work, the available non-corrosive cleaning agent

towels,

cleaning furnace surface to prevent damage to the surface lining.

.Electrical schematics:

EH- Electric tube

HL1- Power indicator

S- Temperature Controller

Reviews: