manualshive.com logo in svg
background image

 

1

UPIC-5 ZBS Infrared Universal Remote Control 

 

Introduction 

UPIC5-ZBS is a ZigBee Infrared Remote Control. It is designed to operate your home appliances by transmitting 
IR signal. The IR Remote Control is capable of learning IR signal transmitted from the appliance’s remote control. 
After learning the signal, you can remotely control the IR Remote Control via ZigBee network to send signal to 
appliance without using the remote control manually.   
The IR Remote Control utilizes ZigBee technology for wireless signal transmission. ZigBee is a wireless 
communication protocol that is reliable and has low power consumption and high transmission efficiency.  
Based on the IEEE802.15.4 standard, ZigBee allows a large amount of devices to be included in a network and 
coordinated for data exchange and signal transmission. 
The IR Remote Control serves as an end device in the ZigBee network. It can be included in the ZigBee network 
to transmit signal upon activation, but cannot permit any other ZigBee device to join the network through the 
device itself.   

 

Parts Identification 

1. IR Eye 

Transmits IR signal to appliances

.   

2. ZigBee Button 

3. IR Button 
4. ZigBee LED 

Flashes twice – 

IR Remote Control 

successfully joins ZigBee network 

Flashes every 20 minutes – 

IR Remote Control

 has lost connection to 

its current ZigBee network. 

5. IR Indicator LED 

Slow Flash – IR Remote Control under IR learning mode. 
Quick Flash – IR Remote Control receives IR signal under learning 
mode or is transmitting IR signal 
Flash every half second – IR data cleared 
Off – IR Remote Control is storing received IR signal under learning 

mode. 

  – IR Remote Control is in idle mode. 

6. IR Signal Receiver 

7. Low IR Transmission Power Jumper (JP1) 
 
 

 

Jumper ON – IR Transmission power set to Low. 

(Factory Default) 

Jumper OFF – Deselected. 

8. High IR Transmission Power Jumper (JP2) 
 
 

 

Jumper ON – IR Transmission power set to High. 
Jumper OFF – Deselected. 

IMPORTANT NOTE: JP1 and JP2 jumper CANNOT be set to ON at the same time 

9. Dip Switch Set 1 

For setting appliance type 

10. Dip Switch Set 2 

For learning and testing IR signal 

11. Battery Compartment 
12. Wall Mounting Rotational Bracket (Optional) 
 
 

Jumper On 

The jumper link is inserted 
connecting the two pins

 

Jumper Off

if the jumper link is removed or “

parked

” 

on one pin.

 

Jumper On 

The jumper link is inserted 
connecting the two pins

 

Jumper Off

if the jumper link is removed or “

parked

” 

on one pin.

 

Содержание UPIC-5 ZBS

Страница 1: ...smits IR signal to appliances 2 ZigBee Button 3 IR Button 4 ZigBee LED Flashes twice IR Remote Control successfully joins ZigBee network Flashes every 20 minutes IR Remote Control has lost connection to its current ZigBee network 5 IR Indicator LED Slow Flash IR Remote Control under IR learning mode Quick Flash IR Remote Control receives IR signal under learning mode or is transmitting IR signal F...

Страница 2: ... Remote Control can only join ZigBee network within 3 minutes after power on 1 Insert batteries to power on the IR Remote Control 2 Within 3 minutes press and hold the ZigBee button for 10 seconds then release it to join the network Please make sure the permit join feature on the router or coordinator of your ZigBee network is enabled 3 After joining the ZigBee network the IR Remote Control will b...

Страница 3: ...thers Fan X means the location of this switch has no effect on appliance selection Example a To select Air Conditioner slide Switch 1 to ON and Switch 2 6 to OFF b To select Television slide Switch 2 to ON and Switch 3 6 to OFF ignore Switch 1 position Step 3 Learn IR Data Each appliance type can learn up to 8 IR signals selected with Dip Switch Set 2 Switch 1 Switch 2 Switch 3 Switch 4 Switch 5 S...

Страница 4: ...Switch 3 Switch 4 Switch 5 Switch 6 Appliance Selection ON OFF OFF OFF OFF OFF Type 1 Air Conditioner OFF ON OFF OFF OFF OFF Type 2 Television OFF OFF ON OFF OFF OFF Type 3 Home Audio OFF OFF OFF ON OFF OFF Type 4 Set Top Box OFF OFF OFF OFF ON OFF Type 5 Others Fan Slide more than one switch to ON will select multiple appliance type Example a Slide Switch 1 2 3 4 5 to ON will select all 5 applian...

Страница 5: ... Remote Control to send IR signal 1 learnt in Air Conditioner appliance type IR Signal Coverage IR LED Selection The IR Eye of the IR Remote Control includes 6 LEDs which are used to transmit IR signals with 1 central LED and 5 surrounding LEDs The 5 surrounding LEDs are positioned at 45 angle to the PCB board LED Signal Coverage Each LED transmits IR signal in cone coverage in front of the LED Th...

Страница 6: ...on Power Use the jumper switches JP2 and JP3 to adjust the IR signal transmission power Factory default is set to Low transmission power JP1 ON Setting the jumper to JP2 will increase the IR signal transmission range ...

Страница 7: ...ng 0 32 bytes Read Write O 0x0011 PhysicalEnvironment 8 bit 0x00 0xff Read Write 0x00 O 0x0012 DeviceEnabled Boolean 0x00 0x01 Read Write 0x01 M Attribute of Power CFG Cluster Information Identifier Name Type Range Access Default Mandatory Optional 0x0035 BatteryAlarmMask map8 0b0000 000x Read Write 0x00 0 Attribute of Identify Cluster Information Identifier Name Type Range Access Default Mandator...

Страница 8: ...isable For example 20 100000 in Bit number meaning that only LED 6 The central LED will be activated when UPIC transmit IR signal in this appliance type If you want to set the IR signal to be transmitted with both LED 2 and LED 6 the value in bit number will be 0010 0010 0x22 0 0 1 0 0 0 1 0 Reserved Reserved LED 6 Enable LED 5 Disable LED 4 Disable LED 3 Disable LED 2 Enable LED 1 Disable 0010 00...

Отзывы: