background image

 

 

 

AC CHARGER USER MANUAL

 

 

 

 

 

 

 

 

VER-EVC-7

 

 

Summary of Contents for VER-EVC-7

Page 1: ...AC CHARGER USER MANUAL VER EVC 7 ...

Page 2: ...Environment 5 1 6 Product Naming 6 1 7 Product Structure 6 1 7 1 External Structure 6 1 7 2 Internal Structure 7 2 Operation Instruction 8 2 1 Product Installation 8 2 1 1 Package Verification 8 2 1 2 Installation Preparation 8 2 1 3 Installation Process 9 2 2 Power on Checking 10 2 3 Charging Operation 11 2 3 1 Connect Charger to EV 11 2 3 2 Start Charging Stop Charging 11 3 Troubleshooting 11 4 ...

Page 3: ... attempt to dissemble repair refit the charger If necessary please contact the Verde for assistance Improper operation will result in device damage electric leakage etc 5 Please take caution while charging in the rain or where lightning is present 6 Avoid children using or getting close to the charging unit 7 Whilst charging the EV should not be driven Only charge the EV when the vehicle has come ...

Page 4: ... panel helps you understand what is happening with the charger by indicating different colors The protection grade of the charger is IP65 water and rust proof assuring the safe outdoor operation and maintenance The floor stand installation is optional by ordering an additional pillar Designed according to Electric Vehicle Charging System Standard EN 61851 1 2011 and EN 61851 22 2002 the charger is...

Page 5: ...ge AC230V 20 Input Frequency 50 60Hz Max Power 7kW Output Voltage AC230V 20 Max Output Current 32A RCD 6mA DC Standby Power 1W Environment al Index Application Place Indoor Outdoor Working Temp 30 55 Working Humidity 5 95 without condensation Working Altitude 2000m Protection Grade IP65 Cooling Method Natural air cooling Safety Standard EN 61851 1 2011 EN 61851 22 2002 MTBF 100 000 hours Special P...

Page 6: ...n The device is equipped with a type 2 charging gun Easy Wall Mount Installation simply fix charger to wall with an anti theft screw All Direction Protection Protections from over voltage under voltage over load current leakage ground fault over temperature under temperature to ensure the device is working safely Safety Design The charger is designed with over current and ground fault protection c...

Page 7: ... 6 1 6 Product Naming VER EVC 7 Charger version Electric Vehicle Charger Product Code of AC charger Verde 1 7 Product Structure 1 7 1 External Structure ...

Page 8: ... 7 1 7 2 Internal Structure ...

Page 9: ...ou have received an incorrect type or quantity contact the seller at once 2 1 2 Installation Preparation 1 Tools Tool Name Photo Function Multimeter Check electrical connection and electrical parameter Cross Screwdriver PH2x150mm PH3x250mm Tight the screws Insulated Torque Wrench Tight the bolts Electric drill Hole on the wall Diagonal Pliers Cut cables 2 Cables Materials Name Specification Quanti...

Page 10: ...to recognize and avoid the hazards involved b All applicable local regional and national regulations must be respected when installing repairing and maintaining this device 2 Installation Procedure 1 According to the cases of the attached installation board drill 3 Φ 6 35 mm holes on the wall and insert the expansion pipe 2 Lock the 2 M4 32mm self tapping screw into the expansion pipe and reserve ...

Page 11: ...r 2 Power on Charger 1 Make sure all checking is done according to the above items 2 Turn on the current leakage protection switch of AC input 3 Power on the charger and observe the LED indicator which should be standby status State Description LED Status Standby Power on but no gun plugged in Flashing green 1S on 3S off Ready to charge Gun plugged in but not start charging yet Flashing yellow 15 ...

Page 12: ...ption LED Status In the standby Normal Flashing green 1S on 3S off Charging status Normal Breathing green 1S on 1S off Plugged gun state Normal Green light normally on Software upgrade Normal Green light flash Ground warning Normal Flashing yellow 2S on 2S off Relay adhesion Fault Red light normally on Input polarity reverse Fault Flashing red 500ms on 500ms off 1 time 3S off Cycle CP fault Fault ...

Page 13: ...age is under 184Vac for a short time wait till the power grid recovers to normal voltage range Input over current AC input current may be too large 1 Shut off the leakage current protection switch of power distribution cabinet immediately 2 Check whether there is low resistance connection between AC output cables of the charger Input over frequency AC input frequency may be too high 1 Check the in...

Page 14: ...t output cables or inverse connection of L N input cables 1 Shut off the leakage current protection switch of power distribution cabinet immediately 2 Check if AC input output cables are normal and if inverse connection of L N input cables Charging cable connection abnormal Poor connection of charging cable with EV Charger 1 Check if charging cable connection is correct and firm Note If the above ...

Page 15: ... 14 please contact your local city office your household waste disposal service or the shop where you purchased the device ...

Page 16: ...e Little Island Cork Ireland T45 R778 www verdeenergygroup com Due to the Verde s policy of continual product development specifications colours and details of our products and those mentioned in this manual are subject to change without notice Version Jul 2021 ...