background image

 
 

MA-SE-HE00-01-11 Manual HEMA eng rev11 

 

Page 

1

 of 

8

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 

 

 
 
 
 

L – LS – LSP 

 
GENERAL DESCRIPTION 

HEMA  L  is  a  low-consumption  sounder  with  high-brightness  LED  flashing  unit  –  anti-opening  and  anti-removal  tamper  –  sound  and  timing 
programming  –  alarm  counting  –  microprocessor  self-test  of:  battery,  speaker  and  drivers  with  dedicated  anomaly  negative  output  – 
programming  of  sounder  trigger  polarity  –  input  for  speaker  block  -  permanent  or  momentary  optical  indication  of  alarm  system  ON/FF 
(arming/disarming) – electronic board protected against polarity inversion and tropicalized 

through a special resin tropicalization process 

against bad weather conditions and moisture

. External cover and sounder base are in ABS while the internal cover is made of zinc-plated 

steel. 
The tamper devices detecting removal, sounder opening, foam and shock are to be connected in series. In case of tamper attempt, they 

open 

the contact between the two TAMPER terminals thus triggering off the alarm. 

HEMA LS: technical features as HEMA L with double micro switch anti-foam circuit provided of anti-shock technology against hard hits. 
HEMA LSP: technical features as HEMA L with double micro switch anti-foam circuit provided of anti-shock technology against hard hits and 
anti-drilling device. 
 

Summary of Contents for HEMA L

Page 1: ...ty inversion and tropicalized through a special resin tropicalization process against bad weather conditions and moisture External cover and sounder base are in ABS while the internal cover is made of...

Page 2: ...from 20 to 100 of RH Size 330x210x110 H x L x W Weight 1 957 gr Standards compliance T031 2014 EN50131 4 2009 Security L and LS models Grade 3 LSP model Grade 4 MOUNTING 1 Use the 6mm plugs to fix the...

Page 3: ...positive missing trigger RES negative trigger for flash reset Note by default DIPSWITCH N 2 is set in OFF position POSITIVE MISSING TRIGGER LEFT FLASH RIGHT FLASH ANTI DRILLING ANTI DRILLING TAMPER T...

Page 4: ...ered to terminal M10 TAMPER A P 4 OPTICAL INDICATION OF SYSTEM STATUS MOMENTARY OR PERMANENT ON OFF If a positive is given to terminal STI System status all LEDs of the flashing light make 3 flashes O...

Page 5: ...lts too At the first sounder supplying 13 8 Vdc or battery anomalies automatically reset once the cause disappears this makes the installation easier After the first activation of the sounder anomalie...

Page 6: ...Vdc C 3 Sounder control chart 5 STI 4 ON OFF indication of alarm system status 5 Input for sound block OUT ANM 6 Fault output Open collector 0 Vdc no anomaly RES 7 Flash reset TAMPER 8 Self protection...

Page 7: ...on for 4 seconds then switch off ON 12 Vdc All LEDs flash 3 times and 1 LED keeps on flashing Not connected or 0 Vdc All LEDs remain steady on for 4 seconds then switch off Chart 8 flash reset mode D...

Page 8: ...01 11 Manual HEMA eng rev11 Page 8 of 8 Product manufactured in Italy Venitem s r l via del Lavoro 10 30030 Salzano VE ITALY Tel 39 0415740374 Fax 39 0415740388 E mail info venitem com website www ve...