background image

 

 

                         
www.velocitydetection.com                        Doc:   GLT-311-7-1                      Issue: 001                              Date: 28/10/2020

 

 

VDOT-U5015 Explosion Proof Smoke Detector 

 

WARNING 

 

 

Be  sure  to  read  and  understand  the  entire  instruction  manual 
before  installing  or  operating  the  smoke  detection  system.  Any 
deviation  from  the  recommendations  in  this  manual  may  impair 
system performance and compromise safety. 

 

 

OVERVIEW

 

 

The 

SmokeWatch™ 

VDOT-U5015 Explosion Proof Smoke Detector 

has Division and Zone explosion-proof ratings and is suitable for 
industrial and commercial applications. The detector is designed to 
operate effectively with smoldering and rapidly growing fires and 
contains the ability to annunciate fault ensuring no undisclosed 
failures. The SmokeWatch VDOT-U5015 Smoke Detector outputs 
include 0-20 mA, a localized LED, and relays.  
 
Typical applications that use the U5015 include:  

 

Combustible storage facilities  

 

Munitions manufacturing  

 

Volatile chemical storage  

 

Chemical processing plants  

 

Petroleum refineries  

 

Turbine enclosures  

 

Battery rooms  

 

HVAC applications  

 
The hot-swappable sensor module is intrinsically safe and allows live 
maintenance while under power, without de-classifying the 
hazardous area.  
 
The integrated junction box is available in a variety of port 
configurations for simplified wiring and installation.  
 
See Figure 1 for all the U5015 Smoke Detector components. 
 

FEATURES 

 

 

FM Approved for use in Class I, Division 1 hazardous  
locations  

 

FM Approved for smoke detection performance  

 

IECEx Zone approved  

 

Trouble-free photoelectric operation  

 

0-20 mA output for DCS integration  

 

Self-checking circuitry ensures reliable smoke detection 

  

Alarm, Auxiliary, and Fault relays for controlling           

 

LED provides a visual indication that an alarm has occurred  

 

IP44 ingress protection level suitable for onshore or  
offshore requirements  

 

BENEFITS

 

 

 

Ideally suited for classified areas in the petrochemical, oil,  
and gas industry  

 

DCS, PLC, integration with milliamp or relay outputs  

 

Rugged design for environmental extremes  

 

Visual confirmation of detector alarm  

 

Detects smoldering fires  

 

No undisclosed failures  

 

                  
 
 
 
           

                              

 

 
 
 
 
 
 
 
 
  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for SmokeWatch VDOT-U5015

Page 1: ...essing plants Petroleum refineries Turbine enclosures Battery rooms HVAC applications The hot swappable sensor module is intrinsically safe and allows live maintenance while under power without de cla...

Page 2: ...om 12 17 9 Vdc 500 ohms from 18 to 19 9 Vdc and 600 ohms from 20 30 Vdc TERMINALS UL CSA rated for 14 18 AWG or 2 5 0 75 mm2 wire THREAD OPTIONS 3 4 inch NPT or M25 Multi port models available ENCLOSU...

Page 3: ...status LATCHING A detector configured for latching operation will remain in an alarm state indefinitely after an alarm occurs NON LATCHING A detector configured for non latching operation will check...

Page 4: ...t be installed in areas in which Ammonia Hydrogen Sulfide and Chlorine are normally present INSTALLATION WARNING All entries must contain appropriately rated plugs or fittings It is required that each...

Page 5: ...ected power supply provides sufficient regulated and filtered output power for the entire system If a back up power system is required a float type battery charging system is recommended If an existin...

Page 6: ...2 to 15 for wiring examples WIRING PROCEDURE Ensure that all cables are terminated properly Conductor insulation should be stripped off with a bare conductor length of 0 2 inch 5 mm minimum and 0 7 in...

Page 7: ...g compartment is the only part of the smoke detector that should be opened by the user in the field ROUTINE INSPECTION Regularly scheduled maintenance is not required however the U5015 cover and smoke...

Page 8: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Page 9: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Page 10: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Page 11: ...t the Velocity Detection office so that a Return Material Authorization RMA number can be assigned A written statement describing the malfunction must accompany the returned device or component to ass...

Page 12: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Page 13: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Page 14: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Page 15: ...www velocitydetection com Doc GLT 311 7 1 Issue 001 Date 28 10 2020 VDOT U5015 Explosion Proof Smoke Detector...

Reviews: