background image

© 2019 Vectorfog is a trademark of Vectornate USA.

All right reserved

DC20+

ULV FOGGER

User Manual

www

.v

ect
orfog.com

Summary of Contents for DC20P

Page 1: ...2019 Vectorfog is a trademark of Vectornate USA All right reserved DC20 ULV FOGGER User Manual www vectorfog com...

Page 2: ...cold fog generated from the machine The micro droplets produced by this machine can float in the air for a long time and are quickly absorbed by the lungs Depending on the chemical being used this co...

Page 3: ...ry Can be operated anywhere without power cord after the battery has been charged Solution Compatibility Compatible with different types of solutions such as water oil air freshener and others Quiet C...

Page 4: ...andle turns red CHARGING 1 2 3 4 4 1 4 2 Connect the charger to the power cable Connect the charger to the charging port on the handle Plug in the power cord to the main power supply Battery takes 3 h...

Page 5: ...inlet Close the cap of the tank securely to prevent chemical leakage FILLING THE TANK The tank capacity is only 2 Liters Do not fill up the tank with solution while recharging the battery Do not fill...

Page 6: ...e machine by sliding the switch to the ON position Turn off the machine by sliding the swtich to the OFF position Adjust the droplet size by turning the nozzle on the front of the machine Clockwise re...

Page 7: ...ny existing liquid remaining in the fogger s internal tubes STEP A Fill the fogger with some clean water and operate again for one minute Remove any excess water from the tank STEP B CLEANUP OF EMULSI...

Page 8: ...PRODUCT www vectorfog com 07 1 2 3 Air Cap Cap Nozzle Nozzle Assy Body Assy Motor Assy Battery Assy 4 5 6 1 8 17 14 19 2 11 10 12 3 6 7 5 15 18 16 4 9 13...

Page 9: ...orfog com 08 PRODUCT 7 8 9 Battery Invertor Switch Assy 10 11 12 PCB Switch PCB Check Valve 13 14 15 Elbow Hose Tank Assy 16 17 18 Tank Cap Air Nipple Water Nipple 19 20 21 Packing Battery Charger Pow...

Page 10: ...y charged Input Voltage Output Voltage Current I Charging Time 2L 0 5 gal 3 2 kg 7 05 lb 2 0 13 1 500 sq ft 140 m 15 20 L h 4 5 3 gal h 100 L min 26 gal min 5 50 Microns 80 Degrees Cordless Ningbo Dec...

Page 11: ...mixture with air and or dust always involves the risk of fire or explosion if there is a source of ignition Observe the explosion limit of a pesticide and avoid over dosage accordingly Only use non i...

Page 12: ...UK 44 0 20 3808 5797 KOREA 82 0 70 4694 2489 US 1 201 482 9835 UK OFFICE KOREA OFFICE US OFFICE Info vectorfog com www vectorfog com...