background image

 1 

Varde Aura 1 

Varde Aura 2 

Varde Aura 3 

Varde Aura 11 

Varde Aura 3 Stone 

Installation  

and User Manual 

Revision 8 

 

 

8th

 v

ers

io

n 1

4/0

5

/20

18

 U

K

 

Pottemagervej 1, 7100 Vejle, Denmark. www.vardeovne.dk 

Summary of Contents for Aura 1

Page 1: ...1 Varde Aura 1 Varde Aura 2 Varde Aura 3 Varde Aura 11 Varde Aura 3 Stone Installation and User Manual Revision 8 8th version 14 05 2018 UK Pottemagervej 1 7100 Vejle Denmark www vardeovne dk...

Page 2: ...ldgaard CEO Varde Ovne A S 23 Warranty All Varde stoves undergo substantial quality control and we take pride in supplying the same high quality at all times We do however offer a 5 year warranty for...

Page 3: ...7 cm Installation height rear 83 cm Distance to non flammable material 5 10 cm recommended Distance to flammable material Rear 12 5 cm Side 30 cm Front 80 cm Height cm 100 Width cm 51 Depth cm 45 Weig...

Page 4: ...not heating the room The wood is too wet all the energy is being used up in drying the wood or the wood is poor quality Check that the smoke guide plate is positioned correctly free passage for smoke...

Page 5: ...uding smoke guide plate Aura 1 and 11 100309 5703505042814 Aura 2 and 3 100318 5703505038831 Gasket for glass and ash pan product number and EAN number 100443 5703505045457 Gasket for door incl glue p...

Page 6: ...ve contact the dealer who sold you the unit or contact your chimney inspector In particular following a long period of time where you have not used the stove before using it again you must make sure t...

Page 7: ...What can you make a fire with This Varde stove has been approved and tested for the combustion of wood Only dry wood may be used with a max water content of 21 and a size that is suitable for the com...

Page 8: ...me Varde Ovne A S Address Pottermagervej 1 7100 Vejle Denmark Fireplace Inspection Name RRF Address Im Lopperfeld 34b 46047 Oberhausen Germany Product Varde Product type Aura 1 11 2 3 and 3 Stone Type...

Page 9: ...tioned next to it However we recommend that you keep a gap of 5 10 cm which will mean that you will be able to clean behind the stove If the chimney cleanout access door is behind the stove make sure...

Page 10: ...door for the combustion air must be drawn to the right so that it is completely open for the combustion air When the fire is burning well remember to close the kindling air again since the stove and...

Page 11: ...note that the damper must never be completely closed There must always be at least 20 cm of free passage through the chimney In some cases it can be an advantage on days when the wind is blowing stron...

Page 12: ...onnect the stove using the rear outlet 13 How it works Fuel air damper or secondary air Turn the damper to the right to open the air Kindling air On ash pan closed Kindling air On ash pan Open Remembe...

Reviews: