Page 2: ...subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him Document nr A 100410 ...

Page 3: ...nd mode 15 6 Closing the reader 17 7 Disassembling the reader 18 8 Default settings 20 8 1 3CT Tool 21 8 2 Setting burst mode using the keypad 22 9 Connecting the card reader to SiPass integrated 23 9 1 Connecting the card reader to SiPass integrated in OSDP mode 23 9 2 Setting OSDP address for the card reader 24 9 3 Connecting the card reader to SiPass integrated in Wiegand mode 24 10 Connecting ...

Page 4: ...om the reader or the controller they are connected to cannot be compromised The readers are made of hard wearing materials and will endure most weather conditions The readers are easy to mount and can be mounted on a flat surface The readers can be cleaned with most kinds of domestic detergents All readers have a multicolour light frame The VR50M MF has a keypad for pin code Vanderbilt 2018 4 A 10...

Page 5: ...Classic up to 6 cm Mifare Plus up to 6 cm Mifare DESfire EV1 EV2 the card must be held to the reader Mifare Classic up to 6 cm Mifare Plus up to 6 cm Mifare DESfire EV1 EV2 the card must be held to the reader Indicators 3 x LED red yellow green 1 x Buzzer Multicolour light frame 3 x LED red yellow green 1 x Buzzer Multicolour light frame Keypad No Yes Operating temperature 40 C to 70 C 40 C to 70 ...

Page 6: ...Cable length guide OSDP Max 8 readers Max 1 km Belden cable Wiegand Max 4 readers Max 30m copper cable 0 5 mm Mullion Reader User Manual Technical data Vanderbilt 2018 6 A 100410 21 06 2018 ...

Page 7: ...vice l Use only spare parts and accessories that have been approved by the manufacturer 3 1 Standards and guidelines European directives Vanderbilt hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 2004 108 EC on Electromagnetic Compatibility EMC The EC Declaration of Conformity is available from your Vanderbilt sales offi...

Page 8: ...ontents that come packaged with the reader 4 1 Reader components 1 Front 6 Location where cables can come through the back 2 Hook 7 Tamper base 3 Base 8 Screw for tamper protection 4 Gasket 9 Mounting holes 5 Knock outs x 2 10 Upper and lower terminal block locations Vanderbilt 2018 8 A 100410 21 06 2018 ...

Page 9: ...OSDP and Wiegand lower terminal block 2 R Y T G H terminal block for Wiegand upper terminal block 3 Mounting screws 4 Cover screw 5 Opening tool Mullion Reader User Manual Reader components and package contents Vanderbilt 2018 9 A 100410 21 06 2018 ...

Page 10: ...all 1 Make a small hole in the base gasket Use this hole to feed the cable through the gasket and into the reader base 2 Attach the base to the wall with three screws one in the middle at the top of the base and one in each of the corners at the bottom of the base 1 Tamper base 2 Tamper screw 3 If tamper protection is required fix the screw into the hole on the tamper base Do not over tighten the ...

Page 11: ...les should be fed through 3 Use a pliers to pull the knock out away from the base 4 Remove the corresponding knockout on the cover 5 Attach the base to the wall with three screws one in the middle at the top of the base and one in each of the corners at the bottom of the base Mullion Reader User Manual Mounting and connecting Vanderbilt 2018 11 A 100410 21 06 2018 ...

Page 12: ...rough the opening and reinsert the gasket Proceed to the instructions for Connecting the cables on the next page Vanderbilt recommends sealing the gap that the knock out creates with a sillicone sealant Do this after you have closed the reader Please note that a reader with a removed knock out is not IP 55 Vanderbilt 2018 12 A 100410 21 06 2018 Mullion Reader User Manual Mounting and connecting ...

Page 13: ...r 1 Set reader to OSDP or Wiegand mode 2 Set OSDP addressing or Wiegand formats 3 Set End Of Line EOL status for the reader This indicates the bottom of the reader 5 3 1 1 OSDP The diagrams below show how to position the jumpers to get the desired functions from the terminal blocks Note that the EOL is ON for a sole reader or for the last reader on the RS485 bus Mullion Reader User Manual Mounting...

Page 14: ...able to connect the cables in OSDP mode 1 Attach the cables according to the respective indicators on the second BA terminal block lower terminal block and the base Reader Controller 0V 12V B B A A 2 Insert the ridge on the end of the terminal block marked B A into the slot marked B A 3 Gently push the terminal block towards the base until it clicks 4 Push the cables back 5 On the reverse of the f...

Page 15: ...en 9502 to connect the cables in Wiegand mode 1 Attach the cables according to the respective indicators on the communication and power terminal block BA terminal block lower terminal block Reader Controller 0V 12V B Wiegand D1 A Wiegand D0 2 Attach the cables on the LED tamper and horn terminal block R Y T G H terminal block upper terminal block Reader Controller R Red LED Y T Tamper input G Gree...

Page 16: ...mper see number 3 in section 6 1 in Connecting the cables on page 13 The EOL jumper is used for RS485 bus termination By default the reader has the termination ON EOL is always off in Wiegand mode Vanderbilt 2018 16 A 100410 21 06 2018 Mullion Reader User Manual Mounting and connecting ...

Page 17: ...of the base into the corresponding slot in the front of the reader and slide down 2 Gently press in the bottom of the reader front until the snap lock confirms a secure attachment 3 Screw the cover screw see number 4 in Package contents on page 9 into the bottom of the reader Vanderbilt 2018 17 A 100410 21 06 2018 ...

Page 18: ...l in the slot between the base and the front and push gently upwards 3 Use the opening tool to pull the reader outwards and upwards 4 When the front of the reader is disconnected from the snap lock lift the front and slide upwards to disengage from the hook at the top Vanderbilt 2018 18 A 100410 21 06 2018 ...

Page 19: ...ock 1 Push down gently on the end of the terminal block marked with either B A or R Y T G H 2 Tilt the terminal block away from the base Mullion Reader User Manual Disassembling the reader Vanderbilt 2018 19 A 100410 21 06 2018 ...

Page 20: ... Yellow Connection Tamper output change to yellow LED with 3CT tool Wiegand heart beat mode OFF Time out for configuration card keypad backlight turns off when this timeout expires subsequent to last keypress 3 seconds Activation time out 30 seconds Hold off time for card read 100 milliseconds Reception for card time before the same card will be detected in the field again Inactive Min background ...

Page 21: ...d by the card reader The 3CT tool supports configuration of the following options Tamper Output Yellow Input and Heart beat Mode Option Default setting Information Yellow input Disabled Selects Tamper Output when disabled Heart beat mode Disabled Ensures a comms message is sent every 10 seconds to controller when enabled For more information on 3CT please see the User manual for Configuration Card...

Page 22: ...1 and Jumper 3 are removed 2 Power up the reader while holding the X key The red and green indicators alternately turn on 3 Press the key sequence 1414 to specify that 4 bit burst is required 4 Hold down the key until you hear the affirmative beep 5 To change back to 8 bit burst from 4 bit burst follow the steps above pressing the key sequence 1818 instead of 1414 Vanderbilt 2018 22 A 100410 21 06...

Page 23: ...DP C Reader 1 Mullion reader with keypad D Reader 2 Mullion reader E Reader 3 VR40S MF Mifare Reader with keypad and display The connection between a card reader and a Reader Interface Module RIM is as follows RIM DRI ERI VRxx MF 12 V 0V Tx A Rx B SiPass integrated can support both the VR and NGCR readers on the same OSDP bus Vanderbilt 2018 23 A 100410 21 06 2018 ...

Page 24: ... configured to SiPass integrated This can be tested by holding a card next to the reader A correctly configured card reader acknowledges the card according to the SiPass integrated settings Please note that a new card reader will always get the next free bus address For example if a card reader with bus address 5 is removed and a new card reader is installed the new card reader gets address 5 9 3 ...

Page 25: ...er with keypad D Reader 2 Mullion reader E Reader 3 VR40S MF Mifare Reader with keypad and display ACTpro 1520e can support both the VR and NGCR readers on the same OSDP bus The connection between a card reader and an ACTpro 1520e is as follows ACTpro 1520e VRxx MF 12 24 V OSDP NET 0V OSDP NET A A OSDP NET B B Vanderbilt 2018 25 A 100410 21 06 2018 ...

Page 26: ...ller automatically assigns an address to each reader Therefore jumper 2 should be removed for OSDP operation The serial number of the reader is used to identify and enrol a reader on the system This can be found on a sticker on the reverse of the front cover of the reader bordered in red in the image below Mullion Reader User Manual Connecting the card reader to ACT Vanderbilt 2018 26 A 100410 21 ...

Page 27: ...e card reader to ACT in Wiegand mode For more detail on connecting the card reader to ACT via Wiegand see section 5 3 3 in Connecting the cables on page 13 Please note that if you are connecting an exit reader in Wiegand mode you should wire the D0 from the reader to SENSE on the ACTpro 1520e bordered in red on the image on the next page Vanderbilt 2018 27 A 100410 21 06 2018 Mullion Reader User M...

Page 28: ...g the card reader to SPC The SPC connection to a Mullion reader is via Wiegand For more detail on connecting via Wiegand see section 5 3 3 in Connecting the cables on page 13 Vanderbilt 2018 28 A 100410 21 06 2018 ...

Page 29: ...d by the European Directive 2002 96 EC The correct disposal and separate collection of your old appliance will help prevent potential negative consequences for the environment and human health It is a precondition for reuse and recycling of used electrical and electronic equipment For more detailed information about disposal of your old appliance please contact your city office waste disposal serv...

Page 30: ...derbilt International Ltd Clonshaugh Business and Technology Park Clonshaugh Dublin D17 KV 84 Ireland vanderbiltindustries com contact Vanderbilt 2018 Data and design subject to change without notice Supply subject to availability Document ID A 100410 Edition date 21 06 2018 ...

Reviews: