Installationsanleitung

CombiSteamer with fixed water connection
Bauform 60-450

1063723-03

11/02/2021

1063723-03

1

The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.

If used at an altitude of over 2,000 metres, a reduced performance must be expected.

The unpacked appliance has sharp edges.

It is advisable to wear gloves to reduce the risk of injury.

Lift the appliance carefully out of the box. Only lift the appliance using the handles at the side, otherwise there is a risk that the indi-
vidual parts of the appliance will be crushed. The appliance must never be transported upside down.

Validity

These installation instructions apply to:

Model designation

Type

Type of construction

CombiSteamer V6000 45F

CS6T-23033, CS6T-23045

60-450

General information

If installing into a combustible material, the guidelines and standards for low-voltage installations and fire protection
must be strictly observed.
To ensure good ventilation, the niche in which the appliance stands must have a supply air opening of at least
25 cm

2

.

Identification plate

Open the appliance door. The identification plate is located on the left trim panel
(see illustration).

Connection plate

The connection plate is located on the connection cable.

Electrical connections

Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards
for low-voltage installations and the specifications of the local electricity supply companies.

A plug-in appliance may only be connected to a socket outlet with earthing contact, installed according to specifications. An
all-pole mains isolating device with 3 mm contact opening should be provided in the house wiring system. Switches, plug and
socket devices, circuit breakers and fusible cut-outs which are accessible after installation and which have all-poles switching
are permissible as isolating devices. Effective earthing and separately installed neutral and earth conductors ensure safe and
fault-free operation. After installation, live parts and cables with basic insulation must not be accessible. Check old installa-
tions.

Refer to the identification plate for information on the required mains voltage, current type and fuse protection.

Connection cable (applies to Switzerland only)

brown + black

blue

yellow/green

black

blue

yellow/green

brown

L2

L1

N

N

L1

PE/

PE/

400 V 2N~

230 V~

10A

16A

 

 

  

Connection cable (applies to all other countries)