background image

Installation and use manual  models  FAST 02 e FAST 03           rev  1.0.0  October 2013         Page 1 di 19  

 

INSTALLATION AND USE 

MANUAL 

 

 

 

 

 

 

 

 

mod. 

FAST 02

  e  

FAST 03 

ENGLISH MANUAL 

Summary of Contents for FAST 02

Page 1: ...Installation and use manual models FAST 02 e FAST 03 rev 1 0 0 October 2013 Page 1 di 19 INSTALLATION AND USE MANUAL mod FAST 02 e FAST 03 ENGLISH MANUAL ...

Page 2: ...age 7 10 Connection examples page 8 11 Meaning of front LEDs page 11 12 Setting shooting time and fog flow direction page 12 13 Installation exchange and cylinders reset page 13 14 Maintenance page 14 15 Defects and possible solutions page 16 16 WARRANTY page 17 The conditions of use will be accepted automatically breaking the security labels on the product 1 PACKAGE CONTENTS Inside the package yo...

Page 3: ...untry The documents related to certifications can be requested by mail to support urfog com It is not guaranteed by the manufacturer the use of UR Fog system in the presence of objects that may be damaged anyway in contact with substances based on glycol water and alcohol Any employee or worker that may be exposed to fog must be advised in advance and must be verified if there can be any allergy t...

Page 4: ...conds from the point where the machine is installed 12 Setting the shooting time interval between the minimum and maximum shown in the time table avoid doing overshooting even if the produced fog is dry and generally doesn t leave residue A shot that goes far beyond the recommended seconds can create residue problems in the room 13 UR Fog continues to be effective for up to 2 hours without main po...

Page 5: ...m the package unscrew the two screws that stop the right side panel and revome it Inside it is possible to see the front part of the electronic circuit later called as PCB On the side you can see two cylinders one for Fast 03 1C placed on the cylinder plate It is necessary to take away the cylinders to remove the blocks placed in the upper part of the cylinders they are only used to avoid the risk...

Page 6: ...PPLY Power 220V supplies energy only to the heating system Electronic card and the motors of the cylinders are supllied from the alarm system and batteries The heating element is of 1KW at the very beginning power consumption is about 500W and in some minutes it goes down reaching average consumption which is about 40W 60W Do not use inverter or UPS unless you have the certainty that they generate...

Page 7: ...erting the batteries it is important to check they are in a good contact with the battery case to guarantee the proper functioning Describtion of how make tests is in paragraph 14 9 DESCRIPTION OF INPUT AND OUTPUT CONNECTIONS INPUTS 1 12V Power input 2 GND Power input In these inputs is necessary to provide a stable supply between 11V and 14V DC from the alarm control panel or from an external 12V...

Page 8: ...rm central or an electronic panel that can see all those information in real time and take proper action In order to avoid accidental activation with subsequent fog emission the inputs are in negative security for this reason the disconnection of a wire does not cause activation So it is necessary to check carefully the reliability of connections and protect the cables to the control panel to avoi...

Page 9: ...bove Ur Fog is powered by an external power supply When Fast 02 or 03 is used with an external power supply in case of power failure the machine will not be able to shoot For this reason when the anti robbery function must be guaranteed in the absence of power it is needed to add a rechargeable battery with a capacity of 1 2 Ah 12V in parallel to the output of power supply The arming key is import...

Page 10: ...ers door in addition to DL TAMPER the relay switch power max applicable on the outputs 100mA D Example of connection of UR Fog outputs with opened inputs of an alarm system The UR Fog outputs are normally opened and connected with input zones of the alarm control panel normally opened According to the diagram above when there is an empty cylinder the entrance area L3 will detect an alarm if a fail...

Page 11: ... means something is wrong See paragraph 15 DEFECTS AND POSSIBLE SOLUTIONS LED RED It is lightened when at least one cylinder is empty or it is in reserve only FAST 03 1C See paragraph 13 INSTALLATION EXCHANGE AND CYLINDERS RESET LED GREEN Flash lights means the heating process is in progress riscaldamento Fast 02 or Fast 03 in this step is heating but is not ready to shoot Lightened steady green l...

Page 12: ...16 390 550 26 105 190 7 255 390 17 405 565 27 120 210 8 270 410 18 420 590 28 135 230 9 285 430 19 435 605 29 150 250 10 300 450 20 450 620 30 TABLE OF SHOOTING FAST 03 m of fog Seconds of emission m of fog Seconds of emission m of fog Seconds of emission 20 30 1 102 158 6 168 245 11 30 60 2 116 178 7 180 260 12 60 90 3 130 190 8 190 275 13 72 114 4 144 210 9 200 290 14 88 138 5 156 230 10 210 305...

Page 13: ...ing of reserve occurs when the machine has shooted at least 50 of the expected duration of the cylinder calculated in seconds and not in quantity of fluid shooten For this reason it is recommended to use only new cylinders and reset only when you actually inserts a new cylinder After removing the screws from the door take away the cylinders and reset the warning light for empty cylinder After this...

Page 14: ...ower a cylinder plate after an activation without the cylinder use the following instructions from step 6 The scrolling check of the cylinder plates is performed by activating the motors without cylinders with the following sequence 1 Close the jumper W3 putting the card in service mode 2 Close the jumper P3 in the RESET position 3 Hold down the button S1 the buzzer beeps and then Motor 1 down Mot...

Page 15: ... run down it starts a sequence of acoustic signals 2bips minute battery is low 3bips minutes machine is out of use battery too low 10bip minutes batteries missing or bad contact on battery case plug or cable interrupted The anomaly of the batteries also causes the activation of the output fault useful to signal a possible anomaly When the empty batteries are removed from the battery case the buzze...

Page 16: ...ng standard time of heating 60 min The machine does not shoot immediately after arming For security reasons and to avoid false fog emissions in power when the machine is armed it becomes operative only after 20 After this time the emission is instantaneous Wiring error Verify that the alarm once activated has a tension on connectors of at least 12V the buzzer sounds continuously and the LED flashe...

Page 17: ...d in the warranty moving parts and or damages depending on the incorrect use unless it is found a manufacturing defect in origin Liquid and cylinders are not covered by warranty BREAKING THE SECURITY LABELS AND THE OPENING OF THE MACHINE YOU WILL ACCEPT WHAT IS WRITTEN ON THIS MANUAL AND ON THE WEB SITE UR Fog srl legal office Via Giacinto Collegno 11 10143 Torino Italy Tel 011 01 33 037 Fax 011 0...

Page 18: ... MAINTENANCE DATE BATTERY EXCHANGE CYLINDER EXCHANGE SIGNATURE YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO YES NO n NO ...

Page 19: ... OF CE MARK 2013 Con la presente dichiariamo che il prodotto sopraindicato è conforme alle prescrizioni di sistema EN 50131 1 e EN 50131 8 With this document we declare that the specified product is constructed respecting the prescriptions described in EN 50131 1 and EN 50131 8 Il prodotto è conforme alle seguenti norme The product conforms to the following norms CEI EN 50131 1 2012 CEI EN 50131 8...

Reviews: