Page 1: ...600mm 900mm Chimney Cooker Hood Instruction Manual U600SCG U900SCG ...

Page 2: ...d maintenance of your appliance Please take the time to read this User Manual before using your appliance and keep this book for future reference ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE IMPORTANT Keep this Instruction Manual safe for future reference CONTENTS SAFETY WARNINGS 3 INSTALLATION 5 OPERATION 9 CLEANING MAINTENANCE 10 TROUBLE SHOOTING 12 WARRANTY 13 ...

Page 3: ...of air must be adhered to 5 Do not check the status of the filters while the cooker hood is in operation 6 To avoid injury do not touch the light bulb within half an hour after use 7 Do not flambe under the cooker hood 8 Avoid opening the gasometer when there is no pan on the stove as this will damage the filters and is also a fire hazard 9 Hot oil is a fire hazard Constant supervision is required...

Page 4: ...ING The appliance must be switched off before replacing the lamp to avoid the possibility of electric shock 15 WARNING Do not allow anyone other than qualified service personnel to carry out maintenance or repairs as this will void the warranty 16 WARNING Fire Risk if cleaning instructions are not followed as stipulated in the manual 17 WARNING To avoid the risk of electrical hazards install the s...

Page 5: ...talled above it Ducting and ventilation For best performance and lowest noise output we recommend the use of 150mm ducting 125mm ducting may be used but this will reduce performance and increase the noise of the extractor Wherever possible use the rigid circular pipe which has a smooth interior rather than the expanding concertina style ducting The lengths of ducting without affecting performance ...

Page 6: ...irements laid down for this type of product However special care should be taken around the rear of the appliance as these areas are not designed nor intended to be touched and may contain sharp or rough edges that could cause injury Always wear adequate Personal Protective Equipment PPE Note Two people are required to install the chimney hood The fixings supplied are suitable for most installatio...

Page 7: ...type 10mm Fig 8 Secure hood tighten all screws Fig 9 IMPORTANT Only use the screws provided with the extractor to mount the ducting adaptor The use of longer screws may cause damage to the internal wiring which will not be covered by the warranty Mark out wall as required see Fig 4 Fig 6 Tools required 8 Fig 5 7 ...

Page 8: ...g 10 Fix ducting seal joint Fig 11 Mount the chimney Fig 12 Adjust and secure the chimney Fig 13 Note If using the supplied ducting adaptor to reduce the diameter from 150mm to 125mm secure this in before continuing to Fig 11 8 ...

Page 9: ... of cooking Control Panel A Power off Button B Speed level buttons C Light button To switch the extractor light On or Off Press button C To switch on the extractor or to change the speed at any time when the extractor is running Press the relevant B button for the first second or third speed level as required To switch the extractor off Press the A button 9 ...

Page 10: ... can also be washed in a dishwasher ensuring it is placed in an upright position to prevent damage from other items in the dishwasher To remove the grease filter push in the button on the handle and then pull outwards on the filter as shown in Fig 2 When it has been released at the front pull the filter out completely After rinsing and drying reassemble the grease filter to the hood by reversing t...

Page 11: ...ry four to six months depending on the use To attach a new charcoal filter first remove the grease filter as described in Fig 4 To attach the charcoal filter Offer up the charcoal filter as shown in Fig 3 so that the magnetic pins are facing upwards one to the rear and one to either side The filter will be held in place by magnetic force Finally replace the grease filters LED lighting In case of m...

Page 12: ...ower than the recommended height This is normal and the extractor will work again once the motor has cooled sufficiently If your extractor is not working 1 Check that the mains supply has not been switched off 2 Check that the fuse in the spur has not blown DISPOSAL This product must not be disposed with other household waste To prevent possible harm to the environment or human health from uncontr...

Page 13: ... material or in respect of defective workmanship only Univa authorized service agent shall have no liability if in its opinion the defect or fault was caused through faulty installation accidental damage incorrect usage misuse or abuse failure to follow the operating instructions fire flood civil disturbances or any Act of God The company shall not be responsible for damages caused by insect and o...

Page 14: ...ll Park Bekker Road Vorna Valley Midrand Gauteng South Africa P O Box 1482 Halfway House Gauteng 1685 Sales and Marketing Tel 27 11 315 0015 Email sales univa co za Service and Spares Tel 27 11 315 0015 Email support univa co za www univa co za ...