background image

 

 

 

 

 

 

 

 

 

 
 

 

 

73 Mall Drive, Commack, NY    11725    •    631-543-2000 (P)    •    631-589-6975 (F) 

www.unitronusa.com   

•    [email protected] 

 

 

Tablet and Camera 

MANUAL 

 

Summary of Contents for TCS Pro 500

Page 1: ...73 Mall Drive Commack NY 11725 631 543 2000 P 631 589 6975 F www unitronusa com info unitronusa com Tablet and Camera MANUAL ...

Page 2: ... SCREEN ROTATION ON OFF BUTTON 8 RESET BUTTON 8 TOUCH SCREEN ONE TOUCH OPERATION 9 CONTINUOUS TOUCH OPERATION 9 GLIDE OPERATION 9 ACCESSORY INSTALLATION ADAPTERS CONNECTION COMPONENTS 10 C MOUNT ADAPTER INSTALLATION 10 EYEPIECE ADAPTER INSTALLATION 11 SOFTWARE APPLICATIONS OPERATION UNLOCKING THE TCS Pro500 12 USING THE CAMERA 12 IMAGE CAPTURE OVERVIEW 13 CHANGING CAMERA SETTINGS 14 16 IMAGE GALLE...

Page 3: ...10 35º C or 50 95º F with humidity 20 80 DO NOT expose to direct sunlight to avoid distortion and fire Keep in a dust free environment to avoid damage to the unit and image quality Keep away from electromagnetic fields and electrical instruments such as radios speakers etc Audio speakers may create a strong magnetic field a magnetic field may cause data loss or damage to the LCD screen Use only th...

Page 4: ... the Styrofoam container should be retained for reshipment of your TCS Pro500 if needed Avoid placing the TCS Pro500 in dusty surroundings or in high temperature or humid areas as mold and mildew will form Carefully remove the TCS Pro 500 from the Styrofoam container and place it on a flat vibration free surface and away from electromagnetic fields Your TCS Pro500 comes with an A C power cord and ...

Page 5: ... View Side Controls Ports Please remove protective plastic cover before using the side ports Side Buttons Screen Rotation On Off Volume Search Button Volume Menu Button Multi point capacitance touch screen Return Button Power On Off SIM Card Slot Micro SD Card Slot HDMI Reset Mini USB Headphone Jack External AC Power Jack ...

Page 6: ...CS Pro500 shuts down for shortage of power low power reminder will appear after you plug in the adapter After charging for a while the TCS Pro500 will get enough power to go into the main interface automatically It takes approximately 12 15 hours to charge the TCS Pro500 The TCS Pro500 was charged initially before shipment however the battery discharges power when not being used Button Operations ...

Page 7: ...n button ONCE To return to the Home Screen PRESS and HOLD the return button Volume Decrease Menu Button PRESS the Volume Decrease Menu button ONCE to bring up the settings menu along the bottom of the screen PRESS and HOLD the Volume Decrease Menu button for 5 seconds to bring up the Volume Menu You can lower the volume by one increment by pressing the button for 0 5 second ...

Page 8: ...ent by pressing the button for 0 5 second Screen Rotation On Off Button The rotation of the screen can be turned on or off depending on user preference by sliding the button to the appropriate position Reset Button If the TCS Pro500 freezes and the system cannot be shut down using normal methods you can use a fine shaped object such as the end of a paper clip to reset the system by pressing the re...

Page 9: ...pplications icon on the right side of the screen to go to the main menu applications screen If the system is running slowly or some processes are always blocked TOUCH the icon to close all currently running programs Continuous TOUCH Operation TOUCH and hold the screen until related menu appears Glide Operation TOUCH and glide your finger on the screen until in the direction you want to get the gli...

Page 10: ...purchased from your UNITRON distributor Eyepiece Adapter Kit sold separately and can be purchased from your UNITRON distributor Kit includes a 0 5x adapter with Ф23mm Ф30mm and Ф30 5mm adapter rings for different diameter eyepieces holders Installation Connection Via C mount Adapter Screw the TCS Pro500 onto the C mount adapter first then insert the C mount adapter bottom into the trinocular tube ...

Page 11: ...of the ocular tube is too large an optional adapter ring needs to be added onto the ocular tube There are two sizes of adapter rings with diameters of Ф30mm and Ф30 5mm See B below Insert the eyepiece adapter into the adapter ring and then insert the adapter ring into the ocular tube See C below CAUTION The wide angle view of the TCS Pro500 is adjustable to 0 90º incline DO NOT attempt to rotate t...

Page 12: ...00 TOUCH and drag the lock icon upwards to unlock the TCS Pro500 Note the TCS Pro500 will lock when it goes into timeout sleep mode the default setting is set to 10 minutes Using the Camera TOUCH the Camera icon to go to the Image Capture software NOTE To return to the Home Screen PRESS the Return button on the right side of the TCS Pro500 ...

Page 13: ...ill automatically perform a white balance and SAVE the setting PHOTO VIDEO FUNCTIONS To change between image capturing with the camera and video functions simply slide the setting on the CAMERA VIDEO icon to the appropriate setting CAMERA TOUCH the SHUTTER icon to capture an image The image is automatically saved in the image Gallery of the internal memory automatically VIDEO Drag the round icon S...

Page 14: ...ace a white piece of paper onto the microscope TOUCH the WHITE BALANCE icon to process the white balance automatically The preferred color background after completing the White Balance will be a whitish color with a soft gray background When the setting is finished TOUCH the Set icon that appears the system will save the current White Balance and Set white balance successful will appear on the scr...

Page 15: ...e for Exposure and Manual White Balance should be used in conjunction with each other The exposure data is set as low as possible the longer the exposure time the slower the frame rate speed CONTRAST SATURATION TOUCH and DRAG the rectangles icon on the parameter menu bar to adjust the Contrast and Saturation values a Contrast value of 4 or less is recommended GRID FUNCTION The system default setti...

Page 16: ... Due to different electrical frequencies in different countries you should select the correct electrical frequency for your country s standard The system default is set to 60 Hz which is the frequency in the United States If you select improperly you may see noise waves moving across your screen To change the frequency TOUCH the desired frequency under the Flicker reduction menu PREVIEW TOUCH the ...

Page 17: ...ry IMAGE GALLERY From the Applications screen TOUCH the Gallery icon to go into the Gallery Preview TOUCH any photo for 2 seconds then TOUCH the pane on the top right corner of the photo or video a green check mark will appear which indicates it has been selected You can then share delete and edit ...

Page 18: ...s screen to open ES File Explorer DCIM sdcard DCIM folder corresponds to the local hard drive storage extsd folder corresponds to the micro SD card the micro SD card may need to be installed in the slot for this folder to appear in ES File Explorer udisk folder corresponds to the external USB Flash drive disk The USB Flash drive may need to be connected for this folder to appear in ES File Explore...

Page 19: ...hat reads Windows needs to install driver software for your MX53 SMD Android 3 On the TCS Pro500 s Home Screen TOUCH and SLIDE DOWN the top black pull down menu which is now the USB Connect Menu 4 On the TCS Pro500 TOUCH the USB connected bar then TOUCH the Turn on USB storage button on the bottom right of the screen 5 TOUCH the OK button on the pop up screen that reads If you turn on USB Storage ...

Page 20: ...e PC CLICK Open folder to view files You can now locate files from the PC you want to copy to the TCS Pro500 and vice versa using the drag and drop methods with your mouse 8 When finished on the TCS Pro500 TOUCH the Turn off USB storage button on the bottom right of the screen 9 TOUCH the Home button upper left OR the back button upper right to return to the Home screen and then disconnect the USB...

Reviews: