background image

 

HT580 User Reference Guide 

 Unitech Electronic CO. LTD 

Unitech Part Number: 400412 

 

 

Unitech 

 
 

 
 
 
 
 
 

 

 
 
 
 
 
 

 

HT580 User Reference Guide 
 
Version 1.0 
 

 

                                         

Summary of Contents for HT580

Page 1: ...HT580 User Reference Guide Unitech Electronic CO LTD Unitech Part Number 400412 1 Unitech HT580 User Reference Guide Version 1 0...

Page 2: ...n battery pack Due to storage your HT580 s battery may not be fully charged when you first receive it As a precaution please ensure the battery is at full capacity when first starting to use the termi...

Page 3: ...5 Product Illustration 6 1 6 Battery Storage Safety Precautions 7 1 7 Communication Cradle 8 1 8 HT580 Communication with the Host 9 1 9 Interface Port 9 1 10 Pin Assignment 9 1 11 Keypad 10 1 12 Bar...

Page 4: ...meter four foot drops to a concrete floor With all this we believe the HT580 will more than satisfy your own unique retail requirements The HT580 standard package includes the HT580 terminal communic...

Page 5: ...or 12 x 4 characters Battery One 3 7V 600mAH Li ion battery Environmental Sealing IP42 Operation Temperature 0 50 C 32 122 F Storage Temperature 20 70 C 4 158 F Humidity 20 to 85 RH not condensed Ele...

Page 6: ...ailed explanations on some of the functions please refer to subsequent chapters Figure 0 1 HT580 Front View Figure 0 2 HT580 Back View Figure 0 3 HT580 Top View Figure 0 4 HT580 Bottom View Figure 0 5...

Page 7: ...o remove the main battery press down on the release button while pushing out the cover on the unit We suggest that the battery not be removed if possible Charging When starting to operate the HT580 th...

Page 8: ...Position 2 Improper Position The picture to the right shows the proper way to insert your terminal while using the cradle to transmit data or to charge Please note that the connector in the bottom of...

Page 9: ...atus of the cradle itself When the light is on it indicates that data is in transmission 1 8 HT580 Communication with the Host 1 9 Interface Port The HT580 communicates via the RS232 communication por...

Page 10: ...Description To power on the unit press the power key The power key is on top right corner of the cover ESC Returns you back to the previous menu MENU Press MENU to scroll items you require SCAN Press...

Page 11: ...ings To return to the previous menu press ESC 2 1 2 DEVICE When you select device setting you will be able to see three settings as shown below 2 1 2 1 BACKLIGHT Press 1 or scan to enter BACKLIGHT mod...

Page 12: ...ted To execute MODEM INIT press 3 or scan to enter this mode Press ESC to return to the previous menu 2 1 4 SUPERVISOR When entering into SUPERVISOR mode you will be required to input your password Fo...