background image

WMS(N)

 

AUTOMATIC

 

WMX(N)

 

MANUAL

STORAGE HEATER RANGE

 

MODELS: 

WMX706N - 6kWh   

 

WMS/X712N - 12kWh

    WMS/X718N 

18kWh 

 WMS/X724N 

24kWh

INSTALLATION 

 

AND 

 

OPERATING

INSTRUCTIONS

IMPORTANT

PLEASE READ THIS LEAFLET CAREFULLY AND RETAIN FOR FURTHER USE

 NOTE ALSO THE INFORMATION GIVEN ON THE HEATER

 

The Installation must be carried out by trained personnel.

 

A means for disconnection must be incorporated in the 

fi

 xed wiring by a double pole switch with a 

contact separation of a minimum of 3mm and in accordance with the current IEE Wiring Regulations.

 

The heater must not be installed immediately below a 

fi

 xed socket outlet.

 

The heater is not suitable for connection to a 30A ring circuit.

 

Do not position the heater under windows where curtains can contact the heater casing.

 

WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.

 

This heater meets EN60335 safety requirements.  However, any heater type becomes hot in normal 
operation.  Care must be taken to ensure that prolonged skin contact with the heater does not occur.

 

WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE 
MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 
mental capabilities, or lack of experience and knowledge, unless they have been given supervision for 
instruction concerning use of the appliance by a person responsible for their safety.  Children should be 
supervised to ensure that they do not play with the appliance.

 

This appliance is very heavy and must be securely 

fi

 xed to a wall.  DO NOT UNDER ANY CIRCUMSTANCES 

ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.

 

To maintain stability, it is essential that the heater is placed on a level surface and care should be taken 
to avoid irregular surfaces, such as may result from carpets or tiled surrounds partially protruding under 
the heater.

 

This heater must be installed where it is impossible for switches and other controls to be touched by a 
person using a bath or shower.

 

IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the 

fi

 rst few 

days of operation.  ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, 
OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO 
THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.

 

IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS 
DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN 
IDENTICAL PART.