background image

 Professional 

Thern、allmager User 

Manual 

Summary of Contents for UTi165K

Page 1: ...Professional Thern allmager User Manual ...

Page 2: ...lity Uni Trend guarantees that the product is free from any defect in material and workmanship within one year from the purchase da恒 This warranty does not apply to damage caused by accident negligence misuse modification 1恒 nination or improper handling The dealer shall not be entitled togiveany other warranty on behalf of Uni Trend If you need wa ranty service within the warranty period please c...

Page 3: ...e di何erenee什om the measurementenvironment keep it in the measurement environment for 10 to 30 minutes before measuring The product tests the su巾田temperature of the object If temperature compensation is needed please adjust in 1heSettings menu The producthas a self 四libration阳nction If the eading jumpsquickly please l E姐d the temperature after it ge饱steady After m回suring extremely high or low恼mpera...

Page 4: ...ace cover 12 Down button 4 LED light 13 Up bu忧 on 5 Infrared camera lens 14 Replay button 6 Visual light camera lens 15 Right button 7 T igger 16 Back button 8 LCD display 17 SET button 9 Power button 18 Tripod mounting hole Item Desc时ption Item Description 1 Center point temperature 6 High temperature alert sign 2 Maximum temperature 7 Maximum temperature point 3 Self calibration 8 Temperature ba...

Page 5: ...n 3 Press the SET button to enter the Measurement menu 4 Press the up down button to select Center Spot center point measurement or Hilo Spot maximum and minimum temperature measu ement 5 Press the SET button to turn on off Center Spot or Hilo Spot 6 Press the back button to exit 7 5 2 Palette 1 p陪ss the SET button to open伽e main menu 2 Press the left right button to select the圃option 3 Press the ...

Page 6: ...ss the SET button to turn off the point Press the back button to exit 5 4 Image M de 1 Press the SET button to open the main menu 2 Press the left right button to select the固option 3 Press the SET button to enter the Image Mode menu 4 Press the up down button to select the desired mode from Thermal infrared image Digital visual light image and Fusion image blending 5 Press the SET button to apply ...

Page 7: ...Press the up down button to select the Date and Time option in the settings menu 2 Press the SET bu悦 n to enter the Date and Time submenu 3 Press the left right button to select the parameter to be adjusted 4 Press the SET bu悦 n to enter the parameter adjustment state 5 Press the up down button to increase or decrease the value 6 P ess the SET button to save the settings and return to set other pa...

Page 8: ...e or decrease the value 6 Press the SET button to save the cu rent setting 7 Press the back button to exit Note For emissivity values of common materials please refer to伽e Common Emissivity 13 5 5 6 DisplayBrightness 嗣匾翩翩翩 T set display brightness 1 Press the up down button to select the Display Brightness option in the Settings menu 2 Press the SET button to ente the Display Brightness submenu 3 ...

Page 9: ...the back button to exit Note Do not remove or inse同the SD card in saving pictures It is 陪commended to save no more than才000 pictures so as not to a何 ect the response speed of the product When the number ofpictures exceeds 1 000 please clean up the SD card in time 15 5 5 m 监 l L c刮11 司矗 To enter System Settings submenu 1 Press伽e up d口wn button to select伽e Sys怡m Settings option in the Settings menu ...

Page 10: ......

Page 11: ...mals 19 6 5 USB c mmunicati n and Image Projection 1 Download and install the PC software 陪他r to UNI T Documents Download Operation Guide 2 Connect the USBcable to the PC 3 Set the USBmode to USBDisk to browse pictures and analyze data through the PC software set the USBmode to USBCamera to realize real time image projection through the PC software 4 Regarding the usage of the PC software retrieve...

Page 12: ...play resolution 320 240 p民els Field of view FOV ss H x 42 V Battery 3 7V 回OOmAh recha geable Li ion bat阳y Spatial m回lution IFOV 6mrad Thermal sensitivity NETO 50mK Auto power off 5 minutes 10 minutes 30 minutes 仔 default 30 minutes F ame rate 9Hz Ba 忧ery life 二主6 hours Temperature meas1 rement Center point temperature high Charging time 运5 hours display 饱mperature tracking de饱ult Charging voltage ...

Page 13: ...mon Emissivity Material Emissivity Mate ial Emissivity Wood 0 85 Black paper 0 86 Water 0 96 Poly 由rbonate 0 8 Brick 0 75 Concrete 0 97 Stainless s悟el 0 14 Copper oxide 0 78 Tape 0 96 Cast iron 0 81 Aluminum plate 0 09 Rust 0 8 Copperplate 0 06 Gypsum 0 75 Black aluminum 0 95 Paint 0 9 Human skin 0 98 Rubber 0 95 Asphalt 0 96 Soil 0 93 PVC 0 93 23 _ 飞 rC J飞雇主队 Made in China 邑 毡 24 ...

Reviews: