background image

REV 2023-03

USER MANUAL

 

 UG2000DM AND UG2000DMV
AUTOMATIC SPRAY GUN CLEANERS

 

Uni-ram Corporation  

 

 

 

 

 

www.uniram.com

381 Bentley St.  

 

 

 

 

 

 

905-477-5911

Markham On L3R 1P7 

 

 

 

 

 

[email protected]

Summary of Contents for UG2000DMV

Page 1: ...REV 2023 03 USER MANUAL UG2000DM AND UG2000DMV AUTOMATIC SPRAY GUN CLEANERS Uni ram Corporation www uniram com 381 Bentley St 905 477 5911 Markham On L3R 1P7 sales uniram com ...

Page 2: ...ditional feature of venting Raising the lid initiates the venting system and removes fumes from the cleaning tank for the health of the operator CAUTIONS AND WARNINGS Always disconnect this machine from power sources before performing maintenance Do not smoke or use near open flames sparks or heat Make sure all ground wires are connected and that unit itself is grounded properly SAFETY EQUIPMENT W...

Page 3: ...UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 Drain Valve inside Drain Hose Suction hose for Wash pail and suction hose for brush Wash Pail Foot petal for brush Timer UG2000DM FIGURE 1 Cleaning Tank inside ...

Page 4: ...Raising the lid initiates the venting system and removes fumes from the cleaning tank for the health of the operator The vent pipe is to be connected to the venting system in the facility Air Rinse To evacuate the solvent from the spray gun Air Purge Use of Air Purge prevents solvent from reaching the air passage way of the spray gun This unit has 2 air purges Air Rinse ...

Page 5: ...the Diaphragm Pump an internal Air Pressure Regulator has been installed to limit the air pressure to 85 PSI Do not install a second air pressure regulator or use a pressure set below 85 PSI GROUNDING Connect the green ground wire at the back of the unit to a ground in the building Note The pump and metal tube that inserts into each pail are grounded SOLVENT SELECTION The adhesion quality of autom...

Page 6: ...hown in B photo Pull the gun s trigger to flush the solvent through the fluid channel Dispose of solvent in the waste container not supplied Do not mix water and solvent waste Disposable Cup A B CLEANING SPRAY GUNS AND CUPS Remove digital air gauge if so equipped A Loosen the air cap of the spray gun two full turns B Lock the trigger in the open position with the Trigger Lock Spring C A B C ...

Page 7: ...NSTALLING SPRAY GUNS IN TANK Place the spray gun on the nozzle with the cap facing the corner Install Air Purge into the air passage way of the spray gun See photo above Nozzle Extension for disposable cups Location for Push On Nozzle Extension Caps points to the corner jets brush Air Purge ...

Page 8: ...8 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...

Page 9: ... tank Step on the foot pedal A dedicated pump delivers wash solvent through the brush left photo below To control the flow of solvent through the Brush adjust the Flow Control also on the front of the unit right photo The spray gun can be washed with the brush before or after Auto wash Dry the spray gun thoroughly REPLACING SOLVENT Replace the solvent when the solvent has lost its cleaning effectiv...

Page 10: ...e filter in a cup of solvent Wash Pail Remove Suction Pipe and Filter Filter REPLACING SOLVENT Replace the solvent when the solvent has lost cleaning effectiveness or after approximately 100 cleanings Close the drain valve see photo below Remove the drain hose and suction pipe Pour wash solvent from wash pail into waste drum rinse out the pail Replace the pail in the cabinet and replace place the dr...

Page 11: ...11 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 TROUBLE SHOOTING ...

Page 12: ...12 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...

Page 13: ...there is a steady hissing sound and the pump is not cycling the spool valve has stalled due to a blocked air pas sage Follow the procedure below to clear the blockage Connect a blow gun to an 85 PSI source Locate the blue hose that extends from the air exhaust port of the diaphragm pump Use a blow gun to blow air into the open end of this hose Turn timer If the procedure is successful the pump wil...

Page 14: ...14 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 UG2000DM FLOW DIAGRAM Use the diagram to trace the flow of compressed air and solvent ...

Page 15: ...15 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 UG200DMV FLOW DIAGRAM Use the diagram to trace the flow of compressed air and solvent ...

Page 16: ...le Adapter Push On Disposable and Conventional Systems 780 3530 Nozzle Adapter Disposable Cup Systems Only 100 413F Paint Cap Holder 115 200 K Mechanical Timer Assembly 5 minutes 140 230 Air Passage Plug 140 2340 Trigger Clamp Plug Kit 113 800 Flow Through Brush Assembly 100 8335 GROUND WIRE 14G GREEN 36 L 100 835 GROUND WIRE 18AWG GREEN 4 FT UDP4TA DUAL DIAPHRAGM PUMP 4 ...

Page 17: ...17 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...

Page 18: ... KIT PLUG FOR GUN 2 14 110 430PPS2 UNIVERSAL NOZZLE ADAPTER 3 25 1 15 QCF901418 QC FITTING ELBOW 90 1 16 102 3022F BRUSH HOLDER 1 17 144 390S MANUAL BRUSH 1 18 120 471 FITTING SET FOR SOLVENT BRUSH 1 19 100 820 PUSH ROD WITH GUIDE CLIP ASSY 1 20 114 800V2 LID SWITCH WITH BRACKET 4 W 1 IN 2 OUT 1 21 100 835 6 GROUND WIRE ASSY 18GA 1300MM GREEN 1 22 120 020PR AIR PRESSURE REGULATOR SET TO 85 PSI 1 2...

Page 19: ...19 MANUAL UG2000DM SERIES SPRAY GUN CLEANERS REVISED 2023 03 ...

Page 20: ... for the return of your original pump Conditions of Warranty As Uni ram Corporation has no control over the working conditions or circumstances under which the purchaser stores handles or uses the product Uni ram makes no warranty or claim either expressed or implied with respect to this product s fitness for any purpose or the result to be obtained from its use This condition applies to the sale ...

Reviews: