background image

RANGE

SEL

MIN/MAX

HOLD

FAST

V

Apo

A

µA

mAµA

A

mA

  10A

MAX

FUSED

  

400mA

MAX

FUSED

MAX

CAT III

600V

CAT II

1000V

DM505

INSTRUCTION MANUAL

ENGLISH

DM505

1000V Digital Multimeter

1000V

CAT II

600V

CAT III

99 Washington Street 
Melrose, MA 02176 

Phone

 781-665-

1400

Toll Free 1-800-517-8431

Visit us at www.T

estEquipmentDepot.com

Summary of Contents for DM505-N

Page 1: ...ED 400mA MAX FUSED MAX CAT III 600V CAT II 1000V DM505 INSTRUCTION MANUAL ENGLISH DM505 1000V Digital Multimeter 1000V CAT II 600V CAT III 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll...

Page 2: ...NINGS 4 OVERVIEW 5 SYMBOLS 6 OPERATING INSTRUCTIONS AC DC Voltage 1000V AC DC 6 Resistance 40M 7 Continuity 7 Diode 8 Capacitance 8 AC DC Microamps 6000 A 9 AC DC Milliamps 400mA 9 AC DC Amps 10A 10 T...

Page 3: ...Backlight Yes Over range OL is displayed Dimensions 6 49 x 3 3 x 2 17 Item Weight 15 0 oz Calibration Recommended annually CAT Rating CAT III 600V CAT II 1000V Certifications cELTus UL 61010 1 2012 3r...

Page 4: ...ce or capacitance Always adhere to national and local safety codes Use proper personal protective equipment PPE to prevent shock and arc blast injury where hazardous live conductors are exposed Always...

Page 5: ...ximum and Minimum readings Press and hold to return to live readings E Select Button Press to select AC DC or Auto Selection in the following functions Voltage A mA Amps F Function Dial Turns on meter...

Page 6: ...25 volts AC or 60 volts DC RMS at either the common or multifunction input ports as measured from earth ground Features RANGE MIN MAX HOLD SEL RANGE SEL MIN MAX HOLD FAST V Apo A A mA A A mA 10A MAX...

Page 7: ...hreshold Overload Protection Approx 1 0V Approx 40 600V Features MIN MAX HOLD Buzzer sounds at less than 40 WARNING Do not measure resistance on a live circuit Continuity RANGE SEL MIN MAX HOLD FAST V...

Page 8: ...V Forward Bias Displays approx voltage drop Features RANGE MIN MAX HOLD AC VOLTS Ranges Accuracy Resolution Overload Protection 10nF to 9999 F 3 0 5 dgts 0 01nF to 1 F 600V Capacitance RANGE SEL MIN M...

Page 9: ...ection 60mA to 400mA 1 2 5 dgts 0 01mA to 0 1mA 600mA 1000V Fast Fuse Minimum sensitivity 5mA AC auto selection mode only DCmA Ranges Accuracy Resolution Overload Protection 60mA to 400mA 1 0 3 dgts 0...

Page 10: ...CAT II 1000V DM505 A A mA A Apo AT DM505 A Test Lead Notes CATIII 1000V Measurement Locations Ensure the test lead shield is pressed firmly in place Failure to use the CATIV shield increases arc flash...

Page 11: ...interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or televisio...

Page 12: ...ther proof of original purchase date will be required before warranty repairs will be rendered Instruments out of warranty will be repaired when repairable for a service charge This warranty gives you...

Reviews: