background image

5 GHz High-Performance 

Integrated InnerFeed 

Antenna

Model: 

AGM5-HP-1724

Summary of Contents for airGrid M5 AGM5-HP-1724

Page 1: ...5 GHz High Performance Integrated InnerFeed Antenna Model AGM5 HP 1724...

Page 2: ......

Page 3: ...Reflector Antenna Feed Feed Extender Feed Support Grid 5 GHz High Performance Integrated InnerFeed Antenna Model AGM5 HP 1724 Quick Start Guide L Bracket Pole Clamps Qty 2 M6 U Bolts Qty 2 M6x20 Bolt...

Page 4: ...visit www ubnt com toughcable Hardware Installation 1 Attach the Feed Support and L Bracket to the Grid Reflector a Orient the Grid Reflector for the appropriate polarization horizontal or vertical W...

Page 5: ...tion 2 Insert the Feed Extender into the Feed Support until it locks into place 3 Route an Ethernet cable through the cable opening of the Feed Support and connect it to the Ethernet port on the back...

Page 6: ...Horizontal Polarization Vertical Polarization WARNING The orientation of the Antenna Feed and Grid Reflector must match the orientation required for your signal polarization horizontal or vertical 5...

Page 7: ...ommodate a 1 25 2 2 pole a Ensure that the cable opening of the Feed Support faces down b Insert each M6 U Bolt into each Pole Clamp and L Bracket c Secure each M6 U Bolt with two M6 Serrated Flange N...

Page 8: ...he Ethernet cable from the airGrid to the Ethernet port labeled POE on the PoE Adapter 2 Connect an Ethernet cable from your LAN to the Ethernet port labeled LAN on the PoE Adapter 3 Connect the Power...

Page 9: ...static IP address on the 192 168 1 x subnet 3 Launch your web browser and type http 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the User...

Page 10: ...ler Compliance Responsibility Devices must be professionally installed and it is the professional installer s responsibility to make sure the device is operated within local country regulatory require...

Page 11: ...bility 125 mph Wind Loading 5 lbf 100 mph ETSI Specification EN 302 326 DN2 Shock and Vibration ETSI300 019 1 4 Certifications FCC IC CE Operating Temperature 30 to 75 C Operating Humidity 5 to 95 Con...

Page 12: ...Building installation shall provide appropriate short circuit backup protection e Protective bonding must be installed in accordance with local national wiring rules and regulations General Warranty U...

Page 13: ...II No modification alteration or addition has been made to the Product by persons other than UBIQUITI NETWORKS or UBIQUITI NETWORK S authorized representatives or otherwise approved by UBIQUITI NETWO...

Page 14: ...ons of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense For MPE and antenna usage det...

Page 15: ...arking on this product represents the product is in compliance with all directives that are applicable to it Alert Sign Follows CE Marking Alert sign must be indicated if a restriction on use applied...

Page 16: ...ad suya desechar este y cualesquiera otros aparatos el ctricos y electr nicos a trav s de los puntos de recogida que ponen a su disposici n el gobierno y las autoridades locales Al desechar y reciclar...

Page 17: ...ice overholder de v sentlige krav og vrige relevante krav i direktiv 1999 5 EF Nederlands Dutch Hierbij verklaart UBIQUITI NETWORKS dat het toestel UBIQUITI NETWORKS device in overeenstemming is met d...

Page 18: ...evanti li hemm fid Dirrettiva 1999 5 EC Norsk Norwegian UBIQUITI NETWORKS erkl rer herved at utstyret UBIQUITI NETWORKS device er i samsvar med de grunnleggende krav og vrige relevante krav i direktiv...

Page 19: ......

Page 20: ...Email support ubnt com Phone 9 a m 5 p m PST 408 942 1153 Online Resources Wiki Page wiki ubnt com Support Forum forum ubnt com Downloads downloads ubnt com w w w u b n t c o m 2012 Ubiquiti Networks...

Reviews: