background image

2.4 GHz High-Performance 

Integrated InnerFeed

®

 

Antenna

Model: AG-HP-2G20 

Summary of Contents for AG-2G20-HP

Page 1: ...2 4 GHz High Performance Integrated InnerFeed Antenna Model AG HP 2G20 ...

Page 2: ...t 24V 0 5A Power Cord Quick Start Guide The Feed Extender Grid Reflector and mounting hardware are packaged separately Products may be different from pictures and are subject to change without notice TERMS OF USE Ubiquiti radio devices must be professionally installed Shielded Ethernet cable and earth grounding must be used as conditions of product warranty TOUGHCable is designed for outdoor insta...

Page 3: ...utdoor environments and destructive ESD events with industrial grade shielded Ethernet cable from Ubiquiti Networks For more details visit www ubnt com toughcable Application Examples The airGrid mounted outdoors with the Grid Reflector installed provides directional outdoor coverage gain reflector dependent The airGrid mounted outdoors without the Grid Reflector installed provides outdoor to indo...

Page 4: ...s above 65 dBm LED will light green when the wireless signal strength is above 73 dBm LED will light amber when the wireless signal strength is above 80 dBm LED will light red when the wireless signal strength is above 94 dBm Ethernet The Ethernet LED will light steady green when an active Ethernet connection is made and flash when there is activity Power The Power LED will light green when the de...

Page 5: ...o the slots Vertical Polarization Horizontal Polarization IMPORTANT The polarization of the airGrids must match on both ends of the wireless link horizontal to horizontal vertical to vertical 2 On the front of the airGrid ensure the polarization indicator V or H properly matches your desired polarization Vertical Polarization Horizontal Polarization ...

Page 6: ... locking tab of the cable feed door facing up c Insert the alignments pins of the Rear Housing into the alignment holes and push until the Rear Housing locks into place with a click Vertical Polarization Horizontal Polarization 4 Insert the Feed Extender into the Rear Housing with the Release Button facing down Push until it locks into place with a click Release Button ...

Page 7: ...cking tab of the cable feed door and detach the door from the Rear Housing 6 Route an Ethernet cable through the Rear Housing and Feed Extender Connect the cable to the Ethernet port on the back of the Antenna Feed ...

Page 8: ...nd push until it locks into place with a click Vertical Polarization Horizontal Polarization 8 Lightly pull the Antenna Feed to ensure that the Release Button is fully engaged and locked into place Antenna Feed Feed Extender Release Button Bottom View Note If you need to remove the Antenna Feed you must depress the Release Button first ...

Page 9: ...n indicator V or H on the Antenna Feed matches the indicator on the Grid Reflector IMPORTANT The polarization indicators must match Vertical Polarization Horizontal Polarization 10 Re attach the cable feed door to the Rear Housing Ensure the locking tab securely latches to the Rear Housing ...

Page 10: ...ole Clamp onto the L Bracket 12 Insert the U Bolt into the Pole Clamp and L Bracket Secure each end of the U Bolt with a Flange Nut 9 N m 80 lb in Note The mounting assembly can accommodate a Ø 32 56 mm 1 25 2 2 pole ...

Page 11: ... Cord to the adapter and then plug the Power Cord into a power outlet Mounting the PoE Adapter Optional 1 Remove the PoE Mounting Bracket from the adapter place the bracket at the desired location and mark the two holes 2 Pre drill the holes if necessary and secure the bracket using two fasteners not included 3 Align the adapter s slots with the tabs of the PoE Mounting Bracket and then slide the ...

Page 12: ...tem with a static IP address on the 192 168 1 x subnet 3 Launch your web browser and type https 192 168 1 20 in the address field Press enter PC or return Mac 4 The login screen will appear Enter ubnt in the Username and Password fields Select your Country and Language You must agree to the Terms of Use to use the product Click Login Note U S product versions are locked to the U S Country Code to ...

Page 13: ...p down list select the appropriate option c Click Change to save d Click OK to confirm Customize additional settings as needed to complete the installation For additional details on the airOS Configuration Interface refer to the User Guide available at documentation ubnt com airmax ...

Page 14: ...ler s responsibility to make sure the device is operated within local country regulatory requirements Since Ubiquiti Networks equipment can be paired with a variety of antennas and cables the Antenna and Output Power fields are provided to the professional installer to assist in meeting regulatory requirements ...

Page 15: ...tput Power 28 dBm Max Power Consumption 3W Power Supply 24V 0 5A PoE Adapter Included Power Method Passive Power over Ethernet Pairs 4 5 7 8 Return Max VSWR 1 5 1 Wind Survivability 200 km h 125 mph Wind Loading 34 7 N 200 km h 7 8 lbf 125 mph ETSI Specification EN 302 326 DN2 Shock and Vibration ETSI300 019 1 4 Certifications FCC IC CE Operating Temperature 30 to 75 C 22 to 167 F Operating Humidi...

Page 16: ...provided only by a qualified service technician 3 This equipment is provided with a detachable power cord which has an integral safety ground wire intended for connection to a grounded safety outlet a Do not substitute the power cord with one that is not the provided approved type Never use an adapter plug to connect to a 2 wire outlet as this will defeat the continuity of the grounding wire b The...

Page 17: ...IV has been subjected to misuse abuse negligence abnormal physical electromagnetic or electrical stress including lightning strikes or accident V has been damaged or impaired as a result of using third party firmware VI has no original Ubiquiti MAC label or is missing any other original Ubiquiti label s or VII has not been received by Ubiquiti within 30 days of issuance of the RMA In addition the ...

Page 18: ... FACILITIES UBIQUITI NETWORKS ITS AFFILIATES AND ITS AND THEIR THIRD PARTY PROVIDERS ARE NOT RESPONSIBLE FOR ANY INTERRUPTIONS DELAYS CANCELLATIONS DELIVERY FAILURES DATA LOSS CONTENT CORRUPTION PACKET LOSS OR OTHER DAMAGE RESULTING FROM ANY OF THE FOREGOING In addition UBIQUITI NETWORKS does not warrant that the operation of the Products will be error free or that operation will be uninterrupted ...

Page 19: ...xpressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipmen...

Page 20: ...ée équivalente PIRE ne dépasse pas ce qui est nécessaire pour une communication réussie Cet appareil est conforme à la norme RSS Industrie Canada exempts de licence norme s Son fonctionnement est soumis aux deux conditions suivantes 1 Cet appareil ne peut pas provoquer d interférences et 2 Cet appareil doit accepter toute interférence y compris les interférences qui peuvent causer un mauvais fonct...

Page 21: ...ce or the shop where you purchased the product Deutsch Die Europäische Richtlinie 2002 96 EC verlangt dass technische Ausrüstung die direkt am Gerät und oder an der Verpackung mit diesem Symbol versehen ist nicht zusammen mit unsortiertem Gemeindeabfall entsorgt werden darf Das Symbol weist darauf hin dass das Produkt von regulärem Haushaltmüll getrennt entsorgt werden sollte Es liegt in Ihrer Ver...

Page 22: ...nsi que tout autre matériel électrique ou électronique par les moyens de collecte indiqués par le gouvernement et les pouvoirs publics des collectivités territoriales L élimination et le recyclage en bonne et due forme ont pour but de lutter contre l impact néfaste potentiel de ce type de produits sur l environnement et la santé publique Pour plus d informations sur le mode d élimination de votre ...

Page 23: ...t conforme aux exigences essentielles et aux autres dispositions pertinentes de la directive 1999 5 CE Deutsch German Hiermit erklärt UBIQUITI NETWORKS dass sich dieses UBIQUITI NETWORKS Gerät in Übereinstimmung mit den grundlegenden Anforderungen und den anderen relevanten Vorschriften der Richtlinie 1999 5 EG befindet Ελληνική Greek Δια του παρόντος UBIQUITI NETWORKS δηλώνει ότι αυτή η συσκευή U...

Page 24: ...alesquiera otras disposiciones aplicables o exigibles de la Directiva 1999 5 CE Polski Polish Niniejszym Ubiquiti Networks oświadcza że urządzenie UBIQUITI NETWORKS jest zgodny z zasadniczymi wymaganiami oraz pozostałymi stosownymi postanowieniami Dyrektywy 1999 5 EC Português Portuguese UBIQUITI NETWORKS declara que este dispositivo UBIQUITI NETWORKS está conforme com os requisitos essenciais e o...

Reviews: