background image

NEO-ANGLE SHOWER

Operators’ Manual 

DOUCHE NÉO-ANGULAIRE

Guide de l'utilisateur 

Customer Service / Service à la clientèle : 1-866-206-0888

Our Customer service staff is available to help you. For help with product assembly, to report damaged or 

missing parts, or for any other information about this product, please call our toll-free number.

SAVE THIS MANUAL

Keep this manual and the original sales invoice in a safe, dry place for future reference.

Notre personnel du service à la clientèle est disponible pour vous aider. Pour obtenir de l’aide pour le montage 

de votre produit, pour signaler des pièces endommagées ou manquantes, ou pour toute autre information à 

propos de ce produit, veuillez composer notre numéro sans frais.

CONSERVEZ CE GUIDE

Conservez ce guide avec la facture d'origine dans un endroit sûr et sec pour référence future.

Model/Modèle : 

70845000-01-02-03

Product picture

Photo du produit

Product picture

Photo du produit

Summary of Contents for 70845000-01-02-03

Page 1: ...nual and the original sales invoice in a safe dry place for future reference Notre personnel du service la client le est disponible pour vous aider Pour obtenir de l aide pour le montage de votre prod...

Page 2: ...Bottom Drip Seal Left Bottom Drip Seal Right...

Page 3: ...y Panel Right Shower Wall Right Glass Door Panel Shower Wall Left Door Handle Glass Clamp M4X30 Truss Head Screw Shower Wall Combined Screw M8 Screw Cover ST4 2X10 Self Drilling Screw M8 Screw Washer...

Page 4: ...s reached Please note The base should be installed on cement Any tiled wall MAKE SURE THE BASE IS LEVEL Walls in your bathroom must be leveled and square for an optimall installation SHOWER BASE WARNI...

Page 5: ...2 SHOWER WALL ASSEMBLY OP T I ONAL Put some water into the base to test the base and make sure there s no hydrops found...

Page 6: ...ll installation before installing the shower No screws are required The only difference resides in the wall channel installation which will be screwed The installation procedure is the same for instal...

Page 7: ...in a new construction 3B BASE INSTALLTION ON TILED WALL 25 30mm SIDE SECTION VIEW Shower base the shower base should be installedbefore installing the tiles About Drywall Tile the shower base should...

Page 8: ...ng holes with a pencil on the inside of the wall channel Use a level to plumb wall channels against the edges of the shower enclosure Repeat on the other side 4 WALL CHANNELS POSITIONING PENCIL LEVEL...

Page 9: ...emove wall channels and drill holes at each mounting hole location 5 WALL CHANNELS INSTALLATION Replace wall channels and secure to walls with M4X30 truss head screws Repeat on the other side After dr...

Page 10: ...all channel as shown Repeat on the other side 6 GLASS DOOR INSTALLATION When installing glass panels make sure that you have a firm grip on the glass When orienting the glass panels make sure that ben...

Page 11: ...Pivot block mounting holes on left 7 LEFT OR RIGHT HINGE INSTALLATION LEFT SIDE HINGES Pivot block mounting holes on right RIGHT SIDE HINGES...

Page 12: ...hen screw in or open on the left hinges on the right side First decide whether you want the door to open on the right hinges on the left side Caps may require a light tapping Please note For informati...

Page 13: ...s sitting flat and even of the six holes in the wall panels and into the wall channels With the 3 2 drill bit provided drill holes through each with ST3 3X13 self drilling screws 9 STATIONARY PANEL IN...

Page 14: ...Use the allen key to install hinges Please note Keep a firm grip on the glass door during the installation until door is secured on its hinges 10 INSTALL DOOR HINGES Install glass door as shown Insta...

Page 15: ...12 DOOR SEAL STRIPS INSTALLATION Install the door seal strips as shown 15MM...

Page 16: ...Silicone sealer must be only applied on the outside of the shower to prevent leaks Allow silicone to dry 48 hours 13 CAULKING WARNING...

Page 17: ...ind or stains caused by different types of water such as hard ferrous or alkaline water RONA cannot be held responsible for the direct or indirect damage caused or resulting from fortuitous occurrence...

Reviews: