background image

PAGE 1 OF 3

0321 TH-7505

 H-7505
BATTERY-POWERED 

PALLET TRUCK

1-800-295-5510

uline.com

OPERATING ISSUE

CAUSES

RECOMMENDATIONS

Unit does not power on 

when battery is inserted.

Battery is not fully inserted 

into the cradle.

Pins are broken, stuck or 

missing.

Ensure battery is fully inserted into the 

cradle. If fully inserted and unit is still 

not powering on, check pins as noted 

in next potential cause.

Check pins in battery cradle. Replace 

any broken pins and ensure the 

broken pins are not stuck in battery.

Battery is not holding a 

charge.

Wall power outlet may not 

be good.

The charger cord needs to 

be inspected.

Pins are broken, stuck or 

missing.

Turn power on unit and verify fuel 

gauge illuminates. If it does, the unit is 

good. Otherwise, use another power 

outlet.

Check the A/C charger cord by 

performing a voltage test. If there 

is an issue, the cord needs to be 

replaced.

Check pins in battery cradle. Replace 

any broken pins and ensure the 

broken pins are not stuck in battery.

Unit only lifts on one side.

Long rods may have come 

unbolted.

Check long rods under forks to 

ensure they have not come unbolted. 

Reattach as needed.

Deadman Switch Error F2,1

Deadman switch needs to 

be adjusted or replaced.

Ensure handle is completely upright 

when turning on unit. Adjust or 

replace deadman switch as needed.

Emergency Reverse Switch 

Error F2,2

Red emergency reverse 

button is jammed.

Check red emergency reverse button 

and ensure it is not wedged in place.

If the problem persists, or if the troubleshooting section does not resolve or describe your problem, contact Uline 

Customer Service at 1-800-295-5510.

TROUBLESHOOTING

Para Español, vea página 2.

Pour le français, consulter la page 3.

Reviews: