HO

W T

O

How to Get a BL67-GW-EN 

Gateway to Communicate with a 

Unitronics Touch Screen Display

Содержание BL67-GW-EN

Страница 1: ...G1005 Revised 1 14 2014 HOW TO How to Get a BL67 GW EN Gateway to Communicate with a Unitronics Touch Screen Display ...

Страница 2: ...7 An RJ45 Ethernet Switch Appropriate Power cable for RJ45 Ethernet Switch One Unitronics Touch Screen Display Appropriate Power cable for Unitronics Touch Screen Display One RJ45 to M12 cable Two RJ45 to RJ45 cables One Unitronics RJ11 to RS232 data cable Any type of sensor I used a Ni20 EM30WD AP6X H1141 Appropriate sensor cable that attaches to BL67 B2M12 P slice housing Software Windows XP ope...

Страница 3: ...69 Fax 763 553 0708 TURCK Minneapolis MN 55441 3 Hardware Configuration Hook up the station in the same configuration show in the below photo Note that RJ 45 A goes from the Ethernet Switch to the Unitronics Touch Screen Display ...

Страница 4: ...4 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 SOFTWARE CONFIGURATION Open BL67 GW EN VisLogic example program Wait for the VisLogic software to open ...

Страница 5: ...www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 5 Connection Communications Check to make sure the correct RS 232 COM Port is selected Click Get OPLC Information ...

Страница 6: ...6 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 Verify OPLC Information pops up Click Exit Connection Download Stop Download Reset ...

Страница 7: ...www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 7 No Yes ...

Страница 8: ...x 763 553 0708 TURCK Minneapolis MN 55441 UNITRONICS TOUCH SCREEN CONFIGURATION Press Activate on the touch screen Notice that the status changes to Connected Trigger the sensor and then press Read Notice that the Read bit is now high ...

Страница 9: ...www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 9 Remove the trigger from the sensor press Read again Notice the Read bit is now low Press the write data on the touch screen ...

Страница 10: ...10 www turck com 1 800 544 7769 Fax 763 553 0708 TURCK Minneapolis MN 55441 Press 1 Press enter Notice that the write value changed to 1 ...