background image

V12.06.19

ASSEMBLY, INSTALLATION AND OPERATING 
INSTRUCTIONS

FOR S WOK AND ST WOK

IMPORTANT – PLEASE READ ALL 

INSTRUCTIONS BEFORE YOU ASSEMBLE, 

INSTALL OR OPERATE THIS APPLIANCE.

Summary of Contents for S Wok

Page 1: ...V12 06 19 ASSEMBLY INSTALLATION AND OPERATING INSTRUCTIONS FOR S WOK AND ST WOK IMPORTANT PLEASE READ ALL INSTRUCTIONS BEFORE YOU ASSEMBLE INSTALL OR OPERATE THIS APPLIANCE ...

Page 2: ...SEMBLY INSTRUCTIONS INSTALLATION INSTRUCTIONS WARNINGS SPECIFICATIONS DIMENSIONS GAS INSTALLATION AND LEAK TEST PROCEDURE WOK OPERATING INSTRUCTIONS TROUBLESHOOTING SERVICE MAINTENANCE WARRANTY 3 4 6 8 9 10 13 14 15 16 CONTENTS ...

Page 3: ...y open flame 3 Open lid or hood 4 If odour continues immediately call your gas supplier or your Fire Department Read all instructions carefully before assembly and usage of the Wok Do not use or store flammable materials in or near this appliance Always leak test check hose connections after filling cylinders Check cylinder condition for rust and that the date stamp is current as every gas cylinde...

Page 4: ...t on the base of the Wok WOK PARTS LIST 1 Bolt the 2 X drip tray brackets onto the base of the Wok using the nuts and bolts provided 2 Now slide the grease tray into position at the base of the Wok between the grease tray support brackets 1 Always remove any plastic protection film covering the Wok and components before assembly 2 Cut away any packaging cable ties that are holding the parts in pla...

Page 5: ...u have assembled the Wok wipe it over to remove greasy fingerprints with stainless steel polish and a soft cloth 3 Now make sure the 2 x enamel burner ring tops are in place over the burners and the wok is assembled ...

Page 6: ...mbustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one of the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover figure 1 Within a partial enclosure that includes an overhead enclosure and no more than two walls figure 2 and 3 Within a partial enclosure tha...

Page 7: ...examples the same principles apply to any other shaped area Both ends open Open side at least 25 of total wall area 30 or more in total of the remaining wall area is open and unrestricted OPEN AT SIDE AT LEAST 25 OF TOTAL WALL AREA 30 OR MORE IN TOTAL OF THE REMAINING WALL AREA IS OPEN AND UNRESTRICTED OPEN SIDE AT LEAST 25 OF TOTAL WALL AREA 30 OR MORE IN TOTAL OF THE REMAINING WALL AREA IS OPEN ...

Page 8: ...ce is fitted by the manufacturer The appliance inlet is 3 8 S A E male and is located at the base of the Wok at the front The minimum capacity propane cylinder for this Wok is 4 KG Warning in freezing conditions the pressure of Propane gas can be reduced in the Cylinder Tank causing a lack of gas pressure this may affect the way the Wok operates The intended use of this Wok is to be installed onto...

Page 9: ...king surface at the rear and either side of the Wok must be non combustible material or have a clearance of 100mm DIMENSIONS OF WOK DIMENSIONS Minimum Side Clearance Allow 200mm Minimum Rear Clearance Allow 200mm Minimum Top Clearance Allow 800mm CLEARANCES TO COMBUSTIBLE MATERIALS ARE AS FOLLOWS S WOK CUT OUT DIMENSIONS 345mm 455mm 145mm ...

Page 10: ... water around the joints and gas cylinder valve NOTE You must have the control knob in the off position and have the gas supply on at the cylinder valve to test for leaks Photo of what a typical leak looks like Photo of what a typical leak looks like Photo of what a good connection looks like i e no bubbles If bubbles appear around the connections you have a leak GAS INSTALLATION AND LEAK TEST PRO...

Page 11: ...nect this hose to the inlet on the right hand side of the Wok Connect the shorter Wok hose to the outlet on the left hand side of the Wok and connect the other end of the hose to the BBQ inlet The hose connections must be connected firmly with a spanner Check that the hose is not kinked or under tension Apart from the connection point the hose must not be touching any part of the barbecue or Wok w...

Page 12: ...ts normal operating position It is recommended that an isolation valve and union be fitted before the Wok refer AS5601 AG601 for correct pipe sizing to ensure adequate gas is supplied to the appliance For natural gas check the pressure of the regulator and adjust it if necessary to the pressure shown on the data plate NOTE Check for leaks after each gas refill GAS INSTALLATION PROPANE GAS TO NATUR...

Page 13: ...330 degrees Celsius if it comes in contact with the flame of the wok IMPORTANT Do not force the control knob it will turn easily depress the knob and turn it anti clockwise The gas control knob can be adjusted from high to low To turn the Wok off simply turn the control knob to the OFF position and then turn off the gas supply at the cylinder or supply To light the Wok manually place a lit match n...

Page 14: ...ts on the burner for the best position for ignition Check that the ignition lead is connected properly as the ignition lead might just need to be firmly connected into either the ignition probe or the ignition button correctly The lead may be damaged also The burner will not light Check the injector nipple that supplies the gas to the burner it may have a blockage Control knob is stiff Remove the ...

Page 15: ...alves or the regulator 7 Periodically remove the burner and scrub it with soapy water and a wire brush Make sure the burner ports are clear from obstructions dust or spiders web that may have built up When replaced turn the burner on and check the flame pattern You want a blue flame with a yellow tip 8 Check the hose for kinks leaks or perishing regularly 9 If you cannot operate the Wok correctly ...

Page 16: ...ner No liability is accepted for loss or damage during transit 2 The appliance is installed by a qualified person and operated and maintained in accordance with the instructions supplied Repairs and service must be carried out by an authorized person 3 Installation must conform to the standards laid down by the local codes or in the absence of local codes with AGA code AG 601 AS 5601 2002 4 No alt...